{"schema_version":"1.0","dataset":"appliances","generated":"2026-09-17","note":"generated is the build date, not a verification date; every record carries its own checked dates","count":28,"site":"https://leisurepowercheck.co.uk","records":[{"id":"cbe-mp2usbc","category":"usb_socket","brand":"CBE","model":"MP2USBC","name":"CBE MP2USBC double USB charging socket (USB-A + USB-C), 12 V input","generic_label":"12V twin USB socket, 5 V / 3 A + 3 A (CBE MP2USBC; 12 V draw not published)","official_url":"https://cbe.it/en/Products/mp2usbc_pdt_5509","figures":{"output_5v_a":6,"average_a":null},"duty_cycle_published":false,"sizing":{"basis":"reader_entered","interlock":null,"blocking_notice":null,"note":"CBE publishes only the 5 V output, '5V/3A USB-A + 5V/3A USB-C', and the input voltage '(Input 12V)'. No 12 V input current, input power, converter efficiency or standby draw is published, so the 12 V draw is the reader's own entry. The 5 V output total of 6 A is recorded as published output, not as a 12 V draw."},"default_hours_per_day":3,"hours_note":"USB charging hours are the reader's assumption; CBE publishes no usage figure.","sources":[{"field_group":"figures.output_5v_a","url":"https://cbe.it/en/Products/mp2usbc_pdt_5509","document_title":"CBE MP2USBC product page","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"MP2USBC 5V/3A USB-A + 5V/3A USB-C double charging socket (Input 12V)","clause":"Description"},{"field_group":"figures.average_a","url":"https://cbe.it/en/Products/mp2usbc_pdt_5509","document_title":"CBE MP2USBC product page","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"No 12 V input current or power figure and no standby consumption is published on the page."}],"gaps":["figures.average_a"],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the CBE MP2USBC product page","source_url":"https://cbe.it/en/Products/mp2usbc_pdt_5509","detected_by":"seed"}],"open_questions":[],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.average_a","line":"No published 12 V current figure found (checked 16 September 2026).","document_title":"CBE MP2USBC product page","url":"https://cbe.it/en/Products/mp2usbc_pdt_5509"}],"absence_by_gap":{"figures.average_a":"No published 12 V current figure found (checked 16 September 2026)."},"source_hosts":["cbe.it"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#cbe-mp2usbc","amps":null,"reader_entered":true,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"dometic-coolmatic-crx-50","category":"compressor_fridge","brand":"Dometic","model":"CoolMatic CRX 50","name":"Dometic CoolMatic CRX 50 compressor fridge","generic_label":"12V compressor fridge, 45 to 50 litre class (Dometic CRX 50 figure)","official_url":null,"figures":{"rated_a":5,"average_w":40,"ah_per_h":1.1,"ambient_c":25,"interior_c":5,"ah_per_h_alt":1.7,"ah_per_h_alt_ambient_c":32,"test_standard":null},"duty_cycle_published":false,"sizing":{"basis":"ah_per_h","interlock":"Dometic's CRX 50 installation and operating manual publishes 'Rated current 12 V⎓: 5.0 A'. That is the current while the compressor runs, about 4.5 times the catalogue average of 1.1 Ah/h. This checker uses the catalogue average and never lets the 5.0 A figure reach the daily total. Calculators seeded from the manual will tell you to buy a bank roughly four times too big.","blocking_notice":null,"note":"The 1.1 Ah/h figure is stated at +25 °C ambient and +5 °C interior. Dometic publishes 1.7 Ah/h at +32 °C ambient. No duty cycle and no test standard are published, so the figure cannot be adjusted for other ambients. The 1.1 Ah/h figure was confirmed on 2026-09-16 in the catalogue page; a claimed 1.4 Ah/h at +25 °C was not found in any Dometic document read."},"default_hours_per_day":24,"hours_note":"A fridge runs continuously; the 24 h is the appliance being switched on, not the compressor running. The compressor duty cycle is inside the maker's average figure and is not published separately.","sources":[{"field_group":"figures.ah_per_h","url":"https://www.metris.hr/download/dometic/pdf/ugradbeni-frizideri/crx-50-65.pdf","document_title":"Dometic catalogue page 118, 'Dometic CoolMatic CRX 50/50S / 65/65S' (section 4.24, Compressor refrigerators, 12 / 24 V DC)","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"distributor","quote":"Current consumption at 12 V: 1.1 Ah/h at +25 °C ambient temperature, 1.7 Ah/h at +32 °C ambient temperature, both at +5 °C interior temperature","clause":"4.24, page 118","note":"Dometic-authored catalogue page read on a distributor server (metris.hr). No catalogue year is printed on the page; the only edition marks are the section number 4.24 and the page number. Every dometic.com CRX 50/65/80 product URL tried on 2026-09-16 returned 404 or redirected to a category listing, so the page could not be re-sourced on the maker's domain."},{"field_group":"figures.average_w","url":"https://www.metris.hr/download/dometic/pdf/ugradbeni-frizideri/crx-50-65.pdf","document_title":"Dometic catalogue page 118, 'Dometic CoolMatic CRX 50/50S / 65/65S' (section 4.24, Compressor refrigerators, 12 / 24 V DC)","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"distributor","quote":"Average power consumption 40 W","clause":"4.24, page 118","note":"The CRX series manual (4445102565) also prints 40 W, but its row is labelled 'Power consumption (AC) (ACDC models only)', so it is not used as the 12 V average."},{"field_group":"figures.rated_a","url":"https://media.dometic.com/externalassets/dometic-coolmatic-crx-65-t_9600026495_76329.pdf","document_title":"Dometic CRX50, CRX65 Compressor refrigerator Installation and Operating Manual (4445102664)","document_date":"2020-08","document_edition":"4445102664 08/2020","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Rated current 12 V⎓: 5.0 A","clause":"13 Technical data","note":"Compressor-running current. Interlocked: never used as a sizing figure. The manual prints the DC symbol ⎓ after 12 V."},{"field_group":"figures.test_standard","url":"https://media.dometic.com/externalassets/dometic-coolmatic-crx-65-t_9600026495_76329.pdf","document_title":"Dometic CRX50, CRX65 Compressor refrigerator Installation and Operating Manual (4445102664)","document_date":"2020-08","document_edition":"4445102664 08/2020","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"Technical data section names a climatic class (T) but no consumption test standard (EN/IEC 62552, ISO 15502 or ISO 7371)."}],"gaps":["figures.test_standard"],"open_questions":["Catalogue page could not be re-sourced on dometic.com on 2026-09-16: product URLs for 9105306565, 9105306567 and the en-gb/en-us/en-se CRX 50 pages returned 404 or redirected to a category listing. The catalogue page carries no printed year; edition is recorded as section 4.24 / page 118 only.","A search-result claim of 1.4 Ah/h at +25 °C for the CRX 50 was not found in any Dometic document read on 2026-09-16 (catalogue page 118, manual 4445102664, manual 4445102565). The catalogue states 1.1 Ah/h."],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Dometic catalogue CRX 50/65 page and the CRX 50 installation and operating manual","source_url":"https://media.dometic.com/externalassets/dometic-coolmatic-crx-65-t_9600026495_76329.pdf","detected_by":"seed"},{"date":"2026-09-16","field":"sources","old":"rated_a sourced to dometic-coolmatic-crx-50-e_9600028416_75862.pdf; official_url set to a dometic.com product page","new":"rated_a re-read in the CRX50/CRX65 manual 4445102664 (08/2020) on media.dometic.com; official_url set to null because every dometic.com CRX 50 product URL returned 404 or a category redirect; 1.1 vs 1.4 Ah/h question resolved to 1.1 in the catalogue","source_url":"https://media.dometic.com/externalassets/dometic-coolmatic-crx-65-t_9600026495_76329.pdf","detected_by":"recheck"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.test_standard","line":"No published test standard found (checked 16 September 2026).","document_title":"Dometic CRX50, CRX65 Compressor refrigerator Installation and Operating Manual (4445102664)","url":"https://media.dometic.com/externalassets/dometic-coolmatic-crx-65-t_9600026495_76329.pdf"}],"absence_by_gap":{"figures.test_standard":"No published test standard found (checked 16 September 2026)."},"source_hosts":["metris.hr","media.dometic.com"],"distributor_hosted":true,"evidence_grades":["manufacturer"],"anchor":"#dometic-coolmatic-crx-50","amps":1.1,"reader_entered":false,"is_inverter":false,"has_interlock":true,"has_blocking_notice":false,"startup_excluded":false},{"id":"dometic-crx-65","category":"compressor_fridge","brand":"Dometic","model":"CoolMatic CRX 65","name":"Dometic CoolMatic CRX 65 compressor fridge","generic_label":"12V compressor fridge, 55 to 60 litre class (Dometic CRX 65 figure)","official_url":null,"figures":{"rated_a":5.5,"average_w":45,"ah_per_h":1.14,"ambient_c":25,"interior_c":5,"ah_per_h_alt":1.8,"ah_per_h_alt_ambient_c":32,"test_standard":null},"duty_cycle_published":false,"sizing":{"basis":"ah_per_h","interlock":"Dometic's CRX 65 installation and operating manual publishes 'Rated current 12 V⎓: 5.5 A'. That is the current while the compressor runs, about 4.8 times the catalogue average of 1.14 Ah/h. This checker uses the catalogue average and never lets the 5.5 A figure reach the daily total. Calculators seeded from the manual will tell you to buy a bank roughly four times too big.","blocking_notice":null,"note":"The 1.14 Ah/h figure is stated at +25 °C ambient and +5 °C interior. Dometic publishes 1.8 Ah/h at +32 °C ambient. No duty cycle and no test standard are published."},"default_hours_per_day":24,"hours_note":"A fridge runs continuously; the 24 h is the appliance being switched on, not the compressor running. The compressor duty cycle is inside the maker's average figure and is not published separately.","sources":[{"field_group":"figures.ah_per_h","url":"https://www.metris.hr/download/dometic/pdf/ugradbeni-frizideri/crx-50-65.pdf","document_title":"Dometic catalogue page 118, 'Dometic CoolMatic CRX 50/50S / 65/65S' (section 4.24, Compressor refrigerators, 12 / 24 V DC)","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"distributor","quote":"Current consumption at 12 V 1.14 Ah/h at +25 °C ambient temperature, 1.8 Ah/h at +32 °C ambient temperature, both at +5 °C interior temperature","clause":"4.24, page 118, CRX 65 block","note":"Dometic-authored catalogue page read on a distributor server (metris.hr). No catalogue year is printed on the page; the only edition marks are the section number 4.24 and the page number. Every dometic.com CRX 50/65/80 product URL tried on 2026-09-16 returned 404 or redirected to a category listing, so the page could not be re-sourced on the maker's domain."},{"field_group":"figures.average_w","url":"https://www.metris.hr/download/dometic/pdf/ugradbeni-frizideri/crx-50-65.pdf","document_title":"Dometic catalogue page 118, 'Dometic CoolMatic CRX 50/50S / 65/65S' (section 4.24, Compressor refrigerators, 12 / 24 V DC)","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"distributor","quote":"Average power consumption 45 W","clause":"4.24, page 118, CRX 65 block"},{"field_group":"figures.rated_a","url":"https://media.dometic.com/externalassets/dometic-coolmatic-crx-65-t_9600026495_76329.pdf","document_title":"Dometic CRX50, CRX65 Compressor refrigerator Installation and Operating Manual (4445102664)","document_date":"2020-08","document_edition":"4445102664 08/2020","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Rated current 12 V⎓: 5.5 A","clause":"13 Technical data, CRX 65 column","note":"Compressor-running current. Interlocked: never used as a sizing figure."},{"field_group":"figures.test_standard","url":"https://media.dometic.com/externalassets/dometic-coolmatic-crx-65-t_9600026495_76329.pdf","document_title":"Dometic CRX50, CRX65 Compressor refrigerator Installation and Operating Manual (4445102664)","document_date":"2020-08","document_edition":"4445102664 08/2020","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"Climatic class T is named; no consumption test standard is named."}],"gaps":["figures.test_standard"],"open_questions":["Catalogue page could not be re-sourced on dometic.com on 2026-09-16 (product URLs 404 or redirect to category)."],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Dometic catalogue CRX 50/65 page and the CRX50, CRX65 installation and operating manual 4445102664","source_url":"https://media.dometic.com/externalassets/dometic-coolmatic-crx-65-t_9600026495_76329.pdf","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.test_standard","line":"No published test standard found (checked 16 September 2026).","document_title":"Dometic CRX50, CRX65 Compressor refrigerator Installation and Operating Manual (4445102664)","url":"https://media.dometic.com/externalassets/dometic-coolmatic-crx-65-t_9600026495_76329.pdf"}],"absence_by_gap":{"figures.test_standard":"No published test standard found (checked 16 September 2026)."},"source_hosts":["metris.hr","media.dometic.com"],"distributor_hosted":true,"evidence_grades":["manufacturer"],"anchor":"#dometic-crx-65","amps":1.14,"reader_entered":false,"is_inverter":false,"has_interlock":true,"has_blocking_notice":false,"startup_excluded":false},{"id":"dometic-crx-80","category":"compressor_fridge","brand":"Dometic","model":"CoolMatic CRX 80","name":"Dometic CoolMatic CRX 80 compressor fridge","generic_label":"12V compressor fridge, 75 to 80 litre class (Dometic CRX 80 figure)","official_url":null,"figures":{"rated_a":5.6,"average_w":48,"ah_per_h":1.19,"ambient_c":25,"interior_c":5,"ah_per_h_alt":2,"ah_per_h_alt_ambient_c":32,"test_standard":null},"duty_cycle_published":false,"sizing":{"basis":"ah_per_h","interlock":"Dometic's CRX 80 installation and operating manual publishes 'Rated current 12 V⎓: 5.6 A'. That is the current while the compressor runs, about 4.7 times the catalogue average of 1.19 Ah/h. This checker uses the catalogue average and never lets the 5.6 A figure reach the daily total. Calculators seeded from the manual will tell you to buy a bank roughly four times too big.","blocking_notice":null,"note":"The 1.19 Ah/h figure is stated at +25 °C ambient and +5 °C interior. Dometic publishes 2.0 Ah/h at +32 °C ambient. No duty cycle and no test standard are published."},"default_hours_per_day":24,"hours_note":"A fridge runs continuously; the 24 h is the appliance being switched on, not the compressor running. The compressor duty cycle is inside the maker's average figure and is not published separately.","sources":[{"field_group":"figures.ah_per_h","url":"https://www.metris.hr/download/dometic/pdf/ugradbeni-frizideri/crx-80-110.pdf","document_title":"Dometic catalogue page 120, 'Dometic CoolMatic CRX 80/80S / 110/110S' (section 4.24, Compressor refrigerators, 12 / 24 V DC)","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"distributor","quote":"Current consumption at 12 V 1.19 Ah/h at +25 °C ambient temperature, 2.0 Ah/h at +32 °C ambient temperature, both at +5 °C interior temperature","clause":"4.24, page 120, CRX 80 block","note":"Dometic-authored catalogue page read on a distributor server (metris.hr). No catalogue year is printed on the page; the only edition marks are the section number 4.24 and the page number. Every dometic.com CRX 50/65/80 product URL tried on 2026-09-16 returned 404 or redirected to a category listing, so the page could not be re-sourced on the maker's domain."},{"field_group":"figures.average_w","url":"https://www.metris.hr/download/dometic/pdf/ugradbeni-frizideri/crx-80-110.pdf","document_title":"Dometic catalogue page 120, 'Dometic CoolMatic CRX 80/80S / 110/110S' (section 4.24, Compressor refrigerators, 12 / 24 V DC)","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"distributor","quote":"Average power consumption 48 W","clause":"4.24, page 120, CRX 80 block"},{"field_group":"figures.rated_a","url":"https://media.dometic.com/externalassets/dometic-crx-50u_9105306125_75862.pdf","document_title":"Dometic CRX50, CRX65, CRX80, CRX110, CRX 140 Compressor refrigerator Installation and Operating Manual (4445102565)","document_date":"2020-07","document_edition":"4445102565 07/2020","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Rated current 12 V⎓: 5.6 A","clause":"13 Technical data, CRX 80 column","note":"Compressor-running current. Interlocked: never used as a sizing figure. This is the North American CRX series manual on media.dometic.com; the row for 40 W / 45 W / 48 W in the same table is labelled 'Power consumption (AC) (ACDC models only)' and is not used here."},{"field_group":"figures.test_standard","url":"https://media.dometic.com/externalassets/dometic-crx-50u_9105306125_75862.pdf","document_title":"Dometic CRX50, CRX65, CRX80, CRX110, CRX 140 Compressor refrigerator Installation and Operating Manual (4445102565)","document_date":"2020-07","document_edition":"4445102565 07/2020","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"Climatic class T is named; no consumption test standard is named."}],"gaps":["figures.test_standard"],"open_questions":["Catalogue page could not be re-sourced on dometic.com on 2026-09-16 (product URLs 404 or redirect to category)."],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Dometic catalogue CRX 80/110 page and the CRX series installation and operating manual 4445102565","source_url":"https://media.dometic.com/externalassets/dometic-crx-50u_9105306125_75862.pdf","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.test_standard","line":"No published test standard found (checked 16 September 2026).","document_title":"Dometic CRX50, CRX65, CRX80, CRX110, CRX 140 Compressor refrigerator Installation and Operating Manual (4445102565)","url":"https://media.dometic.com/externalassets/dometic-crx-50u_9105306125_75862.pdf"}],"absence_by_gap":{"figures.test_standard":"No published test standard found (checked 16 September 2026)."},"source_hosts":["metris.hr","media.dometic.com"],"distributor_hosted":true,"evidence_grades":["manufacturer"],"anchor":"#dometic-crx-80","amps":1.19,"reader_entered":false,"is_inverter":false,"has_interlock":true,"has_blocking_notice":false,"startup_excluded":false},{"id":"dometic-rm-5330","category":"absorption_fridge","brand":"Dometic","model":"RM 5330","name":"Dometic RM 5330 3-way absorption fridge on 12 V","generic_label":"3-way absorption fridge on 12 V, 70 litre class (Dometic RM 5330 figure)","official_url":null,"figures":{"rated_w":120,"ah_per_24h":240,"ambient_c":null,"interior_c":null,"test_standard":null},"duty_cycle_published":false,"sizing":{"basis":"ah_per_24h","interlock":null,"blocking_notice":"2.2 Safety when operating with DC power — NOTICE! Damage hazard. Only select operation with DC power supply (battery mode) if the vehicle engine is running and providing sufficient voltage to the light system, or if you are using a battery monitor.","note":"Dometic publishes the 12 V heating element as '120 W (12 V⎓)' and the daily draw as '240 Ah/24 h (12 V⎓)'. On 12 V the absorption unit runs the element continuously; there is no thermostat cycling in DC mode and no duty cycle to publish. The manual's own notice restricts DC operation to engine running or battery-monitored use, so this record shows the notice before any number. Climatic class 'SN', ambient temperature '+10 °C to +32 °C'; the manual states no test ambient for the 240 Ah/24 h figure."},"default_hours_per_day":2,"hours_note":"Dometic's notice limits DC operation to when the engine is running (or a battery monitor is fitted), so the hours are the reader's driving time, not a published figure. The 2 h default is the checker's assumption; at 240 Ah/24 h that is 20 Ah per 2 h of travel.","sources":[{"field_group":"figures.rated_w","url":"https://media.dometic.com/externalassets/dometic-rm-5330_9105703862_81905.pdf","document_title":"Dometic RM5310, RM5330, RM5380 Absorption refrigerator Installation and Operating Manual (4445102234)","document_date":"2021-04-30","document_edition":"4445102234 2021-04-30","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Power consumption: 120 W (12 V⎓)","clause":"13 Technical data","note":"The manual prints the DC symbol ⎓ after 12 V."},{"field_group":"figures.ah_per_24h","url":"https://media.dometic.com/externalassets/dometic-rm-5330_9105703862_81905.pdf","document_title":"Dometic RM5310, RM5330, RM5380 Absorption refrigerator Installation and Operating Manual (4445102234)","document_date":"2021-04-30","document_edition":"4445102234 2021-04-30","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"240 Ah/24 h (12 V⎓)","clause":"13 Technical data"},{"field_group":"sizing.blocking_notice","url":"https://media.dometic.com/externalassets/dometic-rm-5330_9105703862_81905.pdf","document_title":"Dometic RM5310, RM5330, RM5380 Absorption refrigerator Installation and Operating Manual (4445102234)","document_date":"2021-04-30","document_edition":"4445102234 2021-04-30","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"2.2 Safety when operating with DC power — NOTICE! Damage hazard — Only select operation with DC power supply (battery mode) if the vehicle engine is running and providing sufficient voltage to the light system, or if you are using a battery monitor.","clause":"2.2","note":"Printed as section 2.2 in this edition (the checker spec cited it as 1.2)."},{"field_group":"figures.ambient_c","url":"https://media.dometic.com/externalassets/dometic-rm-5330_9105703862_81905.pdf","document_title":"Dometic RM5310, RM5330, RM5380 Absorption refrigerator Installation and Operating Manual (4445102234)","document_date":"2021-04-30","document_edition":"4445102234 2021-04-30","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"Only 'Climatic class: SN' and 'Ambient temperature: +10 °C to +32 °C' are stated; no test ambient is attached to the 240 Ah/24 h figure."}],"gaps":["figures.ambient_c"],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Dometic RM5310/RM5330/RM5380 installation and operating manual 4445102234","source_url":"https://media.dometic.com/externalassets/dometic-rm-5330_9105703862_81905.pdf","detected_by":"seed"}],"open_questions":[],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.ambient_c","line":"No published statement found (checked 16 September 2026).","document_title":"Dometic RM5310, RM5330, RM5380 Absorption refrigerator Installation and Operating Manual (4445102234)","url":"https://media.dometic.com/externalassets/dometic-rm-5330_9105703862_81905.pdf"}],"absence_by_gap":{"figures.ambient_c":"No published statement found (checked 16 September 2026)."},"source_hosts":["media.dometic.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#dometic-rm-5330","amps":10,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":true,"startup_excluded":false},{"id":"dometic-rua-5208x","category":"absorption_fridge","brand":"Dometic","model":"RUA 5208X","name":"Dometic RUA 5208X 3-way absorption fridge on 12 V","generic_label":"3-way absorption fridge on 12 V, 146 litre class (Dometic RUA 5208X figure)","official_url":null,"figures":{"rated_w":175,"ah_per_24h":346,"ambient_c":32,"interior_c":4,"test_standard":null},"duty_cycle_published":false,"sizing":{"basis":"ah_per_24h","interlock":null,"blocking_notice":"NOTICE! Damage hazard — Only select operation with DC power supply if the vehicle engine is running and providing sufficient voltage to the light system, or if you are using a battery monitor.","note":"Dometic publishes '175 W' at 12 V⎓ and '346 Ah/24 h' at 12 V⎓ for the RUA 5208X, with the footnote '*The power and gas consumptions are measured at 32 °C ambient temperature with 4 °C average cooling temperature in the refrigerator compartment.' Climate class T. The manual's own DC-operation notice is shown before any number. On 12 V the absorption element runs continuously; there is no duty cycle to publish."},"default_hours_per_day":2,"hours_note":"Dometic's notice limits DC operation to when the engine is running (or a battery monitor is fitted), so the hours are the reader's driving time, not a published figure. The 2 h default is the checker's assumption.","sources":[{"field_group":"figures.rated_w","url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","document_title":"Dometic RUA 5208X, RUA 6408X, RUA 8408X Absorption refrigerator Installation and Operating Manual (4445102445)","document_date":"2024-02-19","document_edition":"4445102445 2024-02-19","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Power consumption* – 12 V⎓: 175 W","clause":"14 Technical data, RUA 5208X column","note":"Table lists 'Power consumption*' with sub-rows '– 240 V~' and '– 12 V⎓'. The three columns are RUA 5208X / RUA 6408X / RUA 8408X: 175 W / 275 W / 275 W at 12 V."},{"field_group":"figures.ah_per_24h","url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","document_title":"Dometic RUA 5208X, RUA 6408X, RUA 8408X Absorption refrigerator Installation and Operating Manual (4445102445)","document_date":"2024-02-19","document_edition":"4445102445 2024-02-19","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Energy consumption – 12 V⎓: 346 Ah/24 h","clause":"14 Technical data, RUA 5208X column","note":"Columns RUA 5208X / RUA 6408X / RUA 8408X: 346 Ah/24 h / 400 Ah/24 h / 420 Ah/24 h. The 240 V~ row gives 3.9 kWh/24 h for this model."},{"field_group":"figures.ambient_c","url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","document_title":"Dometic RUA 5208X, RUA 6408X, RUA 8408X Absorption refrigerator Installation and Operating Manual (4445102445)","document_date":"2024-02-19","document_edition":"4445102445 2024-02-19","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"*The power and gas consumptions are measured at 32 °C ambient temperature with 4 °C average cooling temperature in the refrigerator compartment.","clause":"14 Technical data, footnote *"},{"field_group":"sizing.blocking_notice","url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","document_title":"Dometic RUA 5208X, RUA 6408X, RUA 8408X Absorption refrigerator Installation and Operating Manual (4445102445)","document_date":"2024-02-19","document_edition":"4445102445 2024-02-19","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"NOTICE! Damage hazard • Only select operation with DC power supply if the vehicle engine is running and providing sufficient voltage to the light system, or if you are using a battery monitor.","clause":"Safety when operating (page 4), NOTICE list","note":"This manual carries its own DC notice; it differs from the RM 5330 wording only by omitting '(battery mode)'."}],"gaps":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Dometic RUA 5208X/6408X/8408X installation and operating manual 4445102445","source_url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","detected_by":"seed"}],"open_questions":[],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[],"absence_by_gap":{},"source_hosts":["media.dometic.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#dometic-rua-5208x","amps":14.416666666666666,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":true,"startup_excluded":false},{"id":"dometic-rua-6408x","category":"absorption_fridge","brand":"Dometic","model":"RUA 6408X","name":"Dometic RUA 6408X 3-way absorption fridge on 12 V","generic_label":"3-way absorption fridge on 12 V, 180 litre class (Dometic RUA 6408X figure)","official_url":null,"figures":{"rated_w":275,"ah_per_24h":400,"ambient_c":32,"interior_c":4,"test_standard":null},"duty_cycle_published":false,"sizing":{"basis":"ah_per_24h","interlock":null,"blocking_notice":"NOTICE! Damage hazard — Only select operation with DC power supply if the vehicle engine is running and providing sufficient voltage to the light system, or if you are using a battery monitor.","note":"Dometic publishes '275 W' at 12 V⎓ and '400 Ah/24 h' at 12 V⎓ for the RUA 6408X, with the footnote '*The power and gas consumptions are measured at 32 °C ambient temperature with 4 °C average cooling temperature in the refrigerator compartment.' Climate class T. The manual's own DC-operation notice is shown before any number. On 12 V the absorption element runs continuously; there is no duty cycle to publish."},"default_hours_per_day":2,"hours_note":"Dometic's notice limits DC operation to when the engine is running (or a battery monitor is fitted), so the hours are the reader's driving time, not a published figure. The 2 h default is the checker's assumption.","sources":[{"field_group":"figures.rated_w","url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","document_title":"Dometic RUA 5208X, RUA 6408X, RUA 8408X Absorption refrigerator Installation and Operating Manual (4445102445)","document_date":"2024-02-19","document_edition":"4445102445 2024-02-19","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Power consumption* – 12 V⎓: 275 W","clause":"14 Technical data, RUA 6408X column","note":"Table lists 'Power consumption*' with sub-rows '– 240 V~' and '– 12 V⎓'. The three columns are RUA 5208X / RUA 6408X / RUA 8408X: 175 W / 275 W / 275 W at 12 V."},{"field_group":"figures.ah_per_24h","url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","document_title":"Dometic RUA 5208X, RUA 6408X, RUA 8408X Absorption refrigerator Installation and Operating Manual (4445102445)","document_date":"2024-02-19","document_edition":"4445102445 2024-02-19","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Energy consumption – 12 V⎓: 400 Ah/24 h","clause":"14 Technical data, RUA 6408X column","note":"Columns RUA 5208X / RUA 6408X / RUA 8408X: 346 Ah/24 h / 400 Ah/24 h / 420 Ah/24 h. The 240 V~ row gives 5.0 kWh/24 h for this model."},{"field_group":"figures.ambient_c","url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","document_title":"Dometic RUA 5208X, RUA 6408X, RUA 8408X Absorption refrigerator Installation and Operating Manual (4445102445)","document_date":"2024-02-19","document_edition":"4445102445 2024-02-19","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"*The power and gas consumptions are measured at 32 °C ambient temperature with 4 °C average cooling temperature in the refrigerator compartment.","clause":"14 Technical data, footnote *"},{"field_group":"sizing.blocking_notice","url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","document_title":"Dometic RUA 5208X, RUA 6408X, RUA 8408X Absorption refrigerator Installation and Operating Manual (4445102445)","document_date":"2024-02-19","document_edition":"4445102445 2024-02-19","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"NOTICE! Damage hazard • Only select operation with DC power supply if the vehicle engine is running and providing sufficient voltage to the light system, or if you are using a battery monitor.","clause":"Safety when operating (page 4), NOTICE list","note":"This manual carries its own DC notice; it differs from the RM 5330 wording only by omitting '(battery mode)'."}],"gaps":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Dometic RUA 5208X/6408X/8408X installation and operating manual 4445102445","source_url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","detected_by":"seed"}],"open_questions":[],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[],"absence_by_gap":{},"source_hosts":["media.dometic.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#dometic-rua-6408x","amps":16.666666666666668,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":true,"startup_excluded":false},{"id":"dometic-rua-8408x","category":"absorption_fridge","brand":"Dometic","model":"RUA 8408X","name":"Dometic RUA 8408X 3-way absorption fridge on 12 V","generic_label":"3-way absorption fridge on 12 V, 216 litre class (Dometic RUA 8408X figure)","official_url":null,"figures":{"rated_w":275,"ah_per_24h":420,"ambient_c":32,"interior_c":4,"test_standard":null},"duty_cycle_published":false,"sizing":{"basis":"ah_per_24h","interlock":null,"blocking_notice":"NOTICE! Damage hazard — Only select operation with DC power supply if the vehicle engine is running and providing sufficient voltage to the light system, or if you are using a battery monitor.","note":"Dometic publishes '275 W' at 12 V⎓ and '420 Ah/24 h' at 12 V⎓ for the RUA 8408X, with the footnote '*The power and gas consumptions are measured at 32 °C ambient temperature with 4 °C average cooling temperature in the refrigerator compartment.' Climate class T. The manual's own DC-operation notice is shown before any number. On 12 V the absorption element runs continuously; there is no duty cycle to publish."},"default_hours_per_day":2,"hours_note":"Dometic's notice limits DC operation to when the engine is running (or a battery monitor is fitted), so the hours are the reader's driving time, not a published figure. The 2 h default is the checker's assumption.","sources":[{"field_group":"figures.rated_w","url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","document_title":"Dometic RUA 5208X, RUA 6408X, RUA 8408X Absorption refrigerator Installation and Operating Manual (4445102445)","document_date":"2024-02-19","document_edition":"4445102445 2024-02-19","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Power consumption* – 12 V⎓: 275 W","clause":"14 Technical data, RUA 8408X column","note":"Table lists 'Power consumption*' with sub-rows '– 240 V~' and '– 12 V⎓'. The three columns are RUA 5208X / RUA 6408X / RUA 8408X: 175 W / 275 W / 275 W at 12 V."},{"field_group":"figures.ah_per_24h","url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","document_title":"Dometic RUA 5208X, RUA 6408X, RUA 8408X Absorption refrigerator Installation and Operating Manual (4445102445)","document_date":"2024-02-19","document_edition":"4445102445 2024-02-19","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Energy consumption – 12 V⎓: 420 Ah/24 h","clause":"14 Technical data, RUA 8408X column","note":"Columns RUA 5208X / RUA 6408X / RUA 8408X: 346 Ah/24 h / 400 Ah/24 h / 420 Ah/24 h. The 240 V~ row gives 5.8 kWh/24 h for this model."},{"field_group":"figures.ambient_c","url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","document_title":"Dometic RUA 5208X, RUA 6408X, RUA 8408X Absorption refrigerator Installation and Operating Manual (4445102445)","document_date":"2024-02-19","document_edition":"4445102445 2024-02-19","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"*The power and gas consumptions are measured at 32 °C ambient temperature with 4 °C average cooling temperature in the refrigerator compartment.","clause":"14 Technical data, footnote *"},{"field_group":"sizing.blocking_notice","url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","document_title":"Dometic RUA 5208X, RUA 6408X, RUA 8408X Absorption refrigerator Installation and Operating Manual (4445102445)","document_date":"2024-02-19","document_edition":"4445102445 2024-02-19","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"NOTICE! Damage hazard • Only select operation with DC power supply if the vehicle engine is running and providing sufficient voltage to the light system, or if you are using a battery monitor.","clause":"Safety when operating (page 4), NOTICE list","note":"This manual carries its own DC notice; it differs from the RM 5330 wording only by omitting '(battery mode)'."}],"gaps":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Dometic RUA 5208X/6408X/8408X installation and operating manual 4445102445","source_url":"https://media.dometic.com/externalassets/rua8408x_9600003697_111452.pdf","detected_by":"seed"}],"open_questions":[],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[],"absence_by_gap":{},"source_hosts":["media.dometic.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#dometic-rua-8408x","amps":17.5,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":true,"startup_excluded":false},{"id":"eberspacher-airtronic-s2-d2l","category":"diesel_heater","brand":"Eberspächer","model":"Airtronic S2 Commercial D2L","name":"Eberspächer Airtronic S2 D2L diesel air heater (12 V)","generic_label":"2.2 kW diesel air heater (Eberspächer Airtronic S2 D2L figure)","official_url":"https://www.eberspaecher-climate.com/","figures":{"rated_w":34,"startup_w":null,"startup_duration_published":false},"duty_cycle_published":false,"sizing":{"basis":"rated_upper_bound","interlock":null,"blocking_notice":null,"note":"Eberspächer publishes one figure, 'Electrical Power Consumption W 34', with no control range and no statement of the heating stage it applies to, so the checker treats 34 W as an upper bound for running draw. No start-up (glow) power and no start-up duration are published in this document: that absence is recorded as a gap, not a zero. The document adds: 'Provided no limit values are given, the technical data listed is subject to the tolerances usually applicable to heaters of ±10% for nominal voltage, ambient temperature 20°C and reference altitude Esslingen.'"},"default_hours_per_day":6,"hours_note":"Heater run hours are the reader's assumption. Eberspächer publishes no run-time or duty cycle.","sources":[{"field_group":"figures.rated_w","url":"https://www.eberspaecher-climate.com/fileadmin/data/countrysites/EB_UK/product-information/29-2100-20-1046C_airtronic_S2_M2_instructions__print_.pdf","document_title":"Eberspächer 'Airtronic S2 & M2 Commercial / M2 Recreational' technical documentation and operating instructions (29.2100.20.1046 Issue C)","document_date":null,"document_edition":"29.2100.20.1046 Issue C","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Electrical Power Consumption W 34 40 55","clause":"Technical Data – Heater, page 4","note":"Three values across the columns S2 Commercial D2L / M2 Commercial D4L / M2 B4L and D4R. The D2L value is 34 W. 'Heating Performance kW 0.9 to 2.2' for the D2L."},{"field_group":"figures.startup_w","url":"https://www.eberspaecher-climate.com/fileadmin/data/countrysites/EB_UK/product-information/29-2100-20-1046C_airtronic_S2_M2_instructions__print_.pdf","document_title":"Eberspächer 'Airtronic S2 & M2 Commercial / M2 Recreational' technical documentation and operating instructions (29.2100.20.1046 Issue C)","document_date":null,"document_edition":"29.2100.20.1046 Issue C","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"No start-up, ignition or glow-phase power figure and no duration appears in the technical data or the operating instructions."}],"gaps":["figures.startup_w"],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Eberspächer Airtronic S2 & M2 technical documentation 29.2100.20.1046 Issue C","source_url":"https://www.eberspaecher-climate.com/fileadmin/data/countrysites/EB_UK/product-information/29-2100-20-1046C_airtronic_S2_M2_instructions__print_.pdf","detected_by":"seed"}],"open_questions":[],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.startup_w","line":"No published start-up figure found (checked 16 September 2026).","document_title":"Eberspächer 'Airtronic S2 & M2 Commercial / M2 Recreational' technical documentation and operating instructions (29.2100.20.1046 Issue C)","url":"https://www.eberspaecher-climate.com/fileadmin/data/countrysites/EB_UK/product-information/29-2100-20-1046C_airtronic_S2_M2_instructions__print_.pdf"}],"absence_by_gap":{"figures.startup_w":"No published start-up figure found (checked 16 September 2026)."},"source_hosts":["eberspaecher-climate.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#eberspacher-airtronic-s2-d2l","amps":2.8333333333333335,"upper_bound":true,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"labcraft-megalux-pd1","category":"lighting","brand":"Labcraft","model":"Megalux PD1 (PD1_4-1MV)","name":"Labcraft Megalux PD1 surface-mount LED interior light, 10-32 V","generic_label":"12V LED ceiling light, 740 lm class (Labcraft Megalux PD1 figure)","official_url":"https://www.labcraft.co.uk/product/megalux-pd1/","figures":{"average_a":0.48,"average_w":5},"duty_cycle_published":false,"sizing":{"basis":"average_a","interlock":null,"blocking_notice":null,"note":"Labcraft's current page and datasheet head the column 'Current' (the checker spec's wording 'Average Current A 0.48' is from an older sheet). The 5 W variant PD1_4-1MV draws '12V @ 0.48A | 24V @ 0.26A'; the 10 W variant PD1_4-3MV draws '12V @ 0.9A | 24V @ 0.54A'. The 5 W variant is recorded."},"default_hours_per_day":4,"hours_note":"Lighting hours are the reader's assumption; Labcraft publishes no usage figure. 4 h is the checker's default for an evening's use.","sources":[{"field_group":"figures.average_a","url":"https://www.labcraft.co.uk/product/megalux-pd1/","document_title":"Labcraft Megalux PD1 product page, specification table","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"PD1 PD1_4-1MV 10-32V 5W 12V @ 0.48A | 24V @ 0.26A 740lm Ø160 x 13.5mm 136mm","clause":"Specification table (Product, Part No., Voltage, Watts, Current, Lumens, Dimensions, Fixing Centres, Switch)"},{"field_group":"figures.average_w","url":"https://www.labcraft.co.uk/media/wysiwyg/Datasheets/megalux_data_sheet.pdf","document_title":"Labcraft 'Megalux' vehicle LED lighting datasheet (megalux_data_sheet.pdf)","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"PD1_4-1MV 10-32V 5W 12V @ 0.48A | 24V @ 0.26A 740lm Ø 160 x 13.5mm 136mm","clause":"Lighting options table, PD1 row","note":"Same figures as the product page."}],"gaps":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Labcraft Megalux PD1 product page and Megalux datasheet","source_url":"https://www.labcraft.co.uk/product/megalux-pd1/","detected_by":"seed"}],"open_questions":[],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[],"absence_by_gap":{},"source_hosts":["labcraft.co.uk"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#labcraft-megalux-pd1","amps":0.48,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"labcraft-orizon-500","category":"lighting","brand":"Labcraft","model":"Orizon 500 mm (LEDCW500PV3)","name":"Labcraft Orizon 500 mm LED strip light, 12 V","generic_label":"12V LED strip light, 500 mm, 850 lm class (Labcraft Orizon figure)","official_url":"https://www.labcraft.co.uk/products/interior-lighting/strip-lighting/orizon.html","figures":{"average_a":0.48,"average_w":6.4},"duty_cycle_published":false,"sizing":{"basis":"average_a","interlock":null,"blocking_notice":null,"note":"Labcraft's table columns are headed 'Watts' and 'Current'; for a non-dimmed LED strip the stated current is the steady running draw and is used as the average. The 500 mm 12 V variant LEDCW500PV3 is '6.4W, 12V @ 0.48A, 850lm'. A 48-LED 500 mm variant (LEDCW500-48PV3) is 12.8 W / 0.96 A."},"default_hours_per_day":4,"hours_note":"Lighting hours are the reader's assumption; Labcraft publishes no usage figure. 4 h is the checker's default for an evening's use.","sources":[{"field_group":"figures.average_a","url":"https://www.labcraft.co.uk/products/interior-lighting/strip-lighting/orizon.html","document_title":"Labcraft Orizon product page, specification table","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"LEDCW500PV3 6.4W 12V @ 0.48A 850lm 24 522 x 18 x 11mm","clause":"Specification table (Product, Part No., Watts, Current, Lumens, No. LEDS, Dimensions), 12V rows"},{"field_group":"figures.average_w","url":"https://www.labcraft.co.uk/products/interior-lighting/strip-lighting/orizon.html","document_title":"Labcraft Orizon product page, specification table","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"LEDCW500PV3 6.4W 12V @ 0.48A 850lm 24 522 x 18 x 11mm","clause":"Specification table, 12V rows"}],"gaps":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Labcraft Orizon product page specification table","source_url":"https://www.labcraft.co.uk/products/interior-lighting/strip-lighting/orizon.html","detected_by":"seed"}],"open_questions":[],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[],"absence_by_gap":{},"source_hosts":["labcraft.co.uk"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#labcraft-orizon-500","amps":0.48,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"shurflo-trail-king-7","category":"water_pump","brand":"Shurflo (Pentair)","model":"Trail King 7 (2095-204-112)","name":"Shurflo Trail King 7 caravan water pump, 7 l/min 20 psi, 12 V","generic_label":"12V pressurised water pump, 7 l/min class (Shurflo Trail King 7 figure)","official_url":null,"figures":{"rated_a":3.3,"average_a":null},"duty_cycle_published":false,"sizing":{"basis":"rated_upper_bound","interlock":null,"blocking_notice":null,"note":"SHURflo publishes no average or maximum current for this pump. Its product sheet publishes a three-row typical performance table at 12 V DC in which current rises with pressure to 3.3 A at the 1.4 bar (20 PSI) shut-off point; that highest published point is used as an upper bound. Nothing is inferred from the fuse recommendation ('Fuse 10 Amp Time Delay Recommended'). A distributor page (shurflo.eu, Precitrade Kft.) states 'Max Amps 4,5' but that figure appears in no manufacturer document read and is not used."},"default_hours_per_day":0.33,"hours_note":"No pump maker in the survey publishes run minutes per day. The default of 0.33 h (20 minutes) is the reader's assumption and should be replaced with their own estimate.","sources":[{"field_group":"figures.rated_a","url":"https://shurflo.eu/wp-content/uploads/2023/03/shurflo2095_204_412.pdf","document_title":"SHURflo Caravan PRODUCT SHEET OEM 2095-204-112 / Aftermarket 2095-204-412, Trail King 7 (PDS-2095-204-112)","document_date":"2001-08","document_edition":"PDS-2095-204-112, August 2001","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"distributor","quote":"Typical Performance @ 12 VDC — PRESSURE BAR PSI / FLOW GPM LPM / CURRENT AMPS: 0.0 0 1.8 7.0 1.5; 0.7 10 1.5 5.6 2.5; 1.4 20 1.2 4.7 3.3","clause":"Typical Performance @ 12 VDC table","note":"SHURflo-authored sheet (SHURflo Ltd., Crawley address printed) read on shurflo.eu, which its footer identifies as Precitrade Kft., a distributor. Re-source on pentair.com. 3.3 A is the highest published point, at shut-off pressure 20 PSI [1.4 Bar] ± 5 PSI."},{"field_group":"figures.average_a","url":"https://shurflo.eu/wp-content/uploads/2023/03/shurflo2095_204_412.pdf","document_title":"SHURflo Caravan PRODUCT SHEET OEM 2095-204-112 / Aftermarket 2095-204-412, Trail King 7 (PDS-2095-204-112)","document_date":"2001-08","document_edition":"PDS-2095-204-112, August 2001","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"distributor","absent":true,"note":"No average current, maximum current or duty cycle is stated; motor is described as '12VDC Permanent Magnet, Intermittent Duty'."}],"gaps":["figures.average_a"],"open_questions":["Distributor page shurflo.eu states 'Max Amps 4,5' for 2095-204-112; not found in any Pentair/SHURflo document on 2026-09-16. Locate a current Pentair product sheet for 2095-204-112 on pentair.com."],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the SHURflo Trail King 7 product sheet PDS-2095-204-112 (August 2001)","source_url":"https://shurflo.eu/wp-content/uploads/2023/03/shurflo2095_204_412.pdf","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.average_a","line":"No published 12 V current figure found (checked 16 September 2026).","document_title":"SHURflo Caravan PRODUCT SHEET OEM 2095-204-112 / Aftermarket 2095-204-412, Trail King 7 (PDS-2095-204-112)","url":"https://shurflo.eu/wp-content/uploads/2023/03/shurflo2095_204_412.pdf"}],"absence_by_gap":{"figures.average_a":"No published 12 V current figure found (checked 16 September 2026)."},"source_hosts":["shurflo.eu"],"distributor_hosted":true,"evidence_grades":["manufacturer"],"anchor":"#shurflo-trail-king-7","amps":3.3,"upper_bound":true,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"shurflo-trail-king-ii","category":"water_pump","brand":"Shurflo (Pentair)","model":"Trail King II (4029-181-A43 / B43)","name":"Shurflo Trail King II RV/caravan fresh water pump, 12 V","generic_label":"12V pressurised water pump, 7.6 l/min class (Shurflo Trail King II figure)","official_url":"https://www.pentair.com/","figures":{"rated_a":3,"average_a":null},"duty_cycle_published":false,"sizing":{"basis":"rated_upper_bound","interlock":null,"blocking_notice":null,"note":"Pentair publishes no average or maximum current for this pump and states 'Fuse: 5 Amp Recommended'. The fuse rating is NOT a current draw and is not used. The sheet does publish a typical performance table at 12 V in which current rises from 1.1 A at open flow to 3.0 A at 30 PSI (above the 25 PSI shut-off); that highest published point is used as an upper bound."},"default_hours_per_day":0.33,"hours_note":"No pump maker in the survey publishes run minutes per day. The default of 0.33 h (20 minutes) is the reader's assumption and should be replaced with their own estimate.","sources":[{"field_group":"figures.rated_a","url":"https://www.pentair.com/content/dam/extranet/web/nam/shurflo/data-sheets/pds-4029-181-X43.pdf","document_title":"Pentair 'SHURflo Trail King II RV/Caravan Fresh Water Pump – Product Technical Data Sheet' (4029-181-A43 [B43] Rev. 05/14)","document_date":"2014-05","document_edition":"4029-181-A43 [B43] Rev. 05/14","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"TYPICAL PERFORMANCE AT 12V — PRESSURE FLOW CURRENT — BAR PSI GPM LPM AMPS: 0 0 2.0 7.6 1.1; 0.3 5 1.6 6.0 1.6; 0.7 10 1.4 5.3 1.9; 1.0 15 1.2 4.5 2.3; 1.4 20 0.9 3.4 2.6; 1.7 25 0.3 1.1 2.9; 2.0 30 0.0 0.0 3.0","clause":"Typical Performance at 12V table, page 2","note":"3.0 A is the highest published point. Control: 'Shut-Off 1.72 Bar [25 PSI] ± 0.13 Bar [2 PSI]'."},{"field_group":"figures.average_a","url":"https://www.pentair.com/content/dam/extranet/web/nam/shurflo/data-sheets/pds-4029-181-X43.pdf","document_title":"Pentair 'SHURflo Trail King II RV/Caravan Fresh Water Pump – Product Technical Data Sheet' (4029-181-A43 [B43] Rev. 05/14)","document_date":"2014-05","document_edition":"4029-181-A43 [B43] Rev. 05/14","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"No average current, maximum current or duty cycle is stated. 'Fuse: 5 Amp Recommended' is a fuse rating, not a draw. Motor described as '12V DC Permanent Magnet, Intermittent Duty'."}],"gaps":["figures.average_a"],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Pentair SHURflo Trail King II product technical data sheet 4029-181-A43 Rev. 05/14","source_url":"https://www.pentair.com/content/dam/extranet/web/nam/shurflo/data-sheets/pds-4029-181-X43.pdf","detected_by":"seed"}],"open_questions":[],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.average_a","line":"No published 12 V current figure found (checked 16 September 2026).","document_title":"Pentair 'SHURflo Trail King II RV/Caravan Fresh Water Pump – Product Technical Data Sheet' (4029-181-A43 [B43] Rev. 05/14)","url":"https://www.pentair.com/content/dam/extranet/web/nam/shurflo/data-sheets/pds-4029-181-X43.pdf"}],"absence_by_gap":{"figures.average_a":"No published 12 V current figure found (checked 16 September 2026)."},"source_hosts":["pentair.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#shurflo-trail-king-ii","amps":3,"upper_bound":true,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"thetford-t1090-e","category":"compressor_fridge","brand":"Thetford","model":"T1090-E","name":"Thetford T1090-E 12V compressor refrigerator","generic_label":"12V compressor fridge, 84 litre class (Thetford T1090-E figure)","official_url":"https://www.thetford.com/","figures":{"ah_per_24h":25.6,"ambient_c":null,"interior_c":null,"test_standard":"IEC62552-2020 part 3"},"duty_cycle_published":false,"sizing":{"basis":"ah_per_24h","interlock":null,"blocking_notice":null,"note":"Thetford publishes a daily figure, 'Average Ampere Usage** (Ah/24h) 25.6', and is the only maker in the survey to name a test standard for it: '** According IEC62552-2020 part 3.' (printed that way; IEC 62552-3:2020). The sheet states no ambient or interior temperature alongside the figure; the test conditions live in the standard, which is not reproduced in the sheet. It also prints 'Energy Consumption ** (kWh/24h) 0.32'. Climate class is given in two modes: 'Climate Class Day mode SN - T (10 °C - 43°C)' and 'Climate Class Night Mode SN (10 °C - 32 °C)'. No manufacturer in the survey publishes a compressor duty cycle."},"default_hours_per_day":24,"hours_note":"The Ah/24h figure is already a daily total, so the 24 h is only the appliance being switched on. It is not a compressor run-time.","sources":[{"field_group":"figures.ah_per_24h","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Average Ampere Usage** (Ah/24h) 25.6","clause":"T1090-E column","note":"Total Volume (L) 84; Volume freezer (L) 6. Table read with pdftotext; the T1090-E column value is 25.6."},{"field_group":"figures.test_standard","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"** According IEC62552-2020 part 3.","clause":"footnote to the Energy Consumption and Average Ampere Usage rows"},{"field_group":"figures.ambient_c","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"No ambient or interior temperature is stated for the Ah/24h figure; only the climate classes 'SN - T (10 °C - 43°C)' (day mode) and 'SN (10 °C - 32 °C)' (night mode) are given."}],"gaps":["figures.ambient_c"],"open_questions":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025)","source_url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.ambient_c","line":"No published statement found (checked 16 September 2026).","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf"}],"absence_by_gap":{"figures.ambient_c":"No published statement found (checked 16 September 2026)."},"source_hosts":["thetford.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#thetford-t1090-e","amps":1.0666666666666667,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"thetford-t2095-e","category":"compressor_fridge","brand":"Thetford","model":"T2095-E","name":"Thetford T2095-E 12V compressor refrigerator","generic_label":"12V compressor fridge, 90 litre class (Thetford T2095-E figure)","official_url":"https://www.thetford.com/","figures":{"ah_per_24h":30,"ambient_c":null,"interior_c":null,"test_standard":"IEC62552-2020 part 3"},"duty_cycle_published":false,"sizing":{"basis":"ah_per_24h","interlock":null,"blocking_notice":null,"note":"Thetford publishes a daily figure, 'Average Ampere Usage** (Ah/24h) 30.0', and is the only maker in the survey to name a test standard for it: '** According IEC62552-2020 part 3.' (printed that way; IEC 62552-3:2020). The sheet states no ambient or interior temperature alongside the figure; the test conditions live in the standard, which is not reproduced in the sheet. It also prints 'Energy Consumption ** (kWh/24h) 0.36'. Climate class is given in two modes: 'Climate Class Day mode SN-T (10 °C - 43°C)' and 'Climate Class Night Mode SN (10 °C - 32 °C)'. No manufacturer in the survey publishes a compressor duty cycle."},"default_hours_per_day":24,"hours_note":"The Ah/24h figure is already a daily total, so the 24 h is only the appliance being switched on. It is not a compressor run-time.","sources":[{"field_group":"figures.ah_per_24h","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Average Ampere Usage** (Ah/24h) 30.0","clause":"T2095-E column","note":"Total Volume (L) 90; Volume freezer (L) 7. Table read with pdftotext; the T2095-E column value is 30.0."},{"field_group":"figures.test_standard","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"** According IEC62552-2020 part 3.","clause":"footnote to the Energy Consumption and Average Ampere Usage rows"},{"field_group":"figures.ambient_c","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"No ambient or interior temperature is stated for the Ah/24h figure; only the climate classes 'SN-T (10 °C - 43°C)' (day mode) and 'SN (10 °C - 32 °C)' (night mode) are given."}],"gaps":["figures.ambient_c"],"open_questions":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025)","source_url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.ambient_c","line":"No published statement found (checked 16 September 2026).","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf"}],"absence_by_gap":{"figures.ambient_c":"No published statement found (checked 16 September 2026)."},"source_hosts":["thetford.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#thetford-t2095-e","amps":1.25,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"thetford-t2120-c","category":"compressor_fridge","brand":"Thetford","model":"T2120-C","name":"Thetford T2120-C 12V compressor refrigerator","generic_label":"12V compressor fridge, 119 litre class (Thetford T2120-C figure)","official_url":"https://www.thetford.com/","figures":{"ah_per_24h":37,"ambient_c":null,"interior_c":null,"test_standard":"IEC62552-2020 part 3"},"duty_cycle_published":false,"sizing":{"basis":"ah_per_24h","interlock":null,"blocking_notice":null,"note":"Thetford publishes a daily figure, 'Average Ampere Usage** (Ah/24h) 37.0', and is the only maker in the survey to name a test standard for it: '** According IEC62552-2020 part 3.' (printed that way; IEC 62552-3:2020). The sheet states no ambient or interior temperature alongside the figure; the test conditions live in the standard, which is not reproduced in the sheet. It also prints 'Energy Consumption ** (kWh/24h) 0.45'. Climate class is given in two modes: 'Climate Class Day mode SN - T (10 °C - 43°C)' and 'Climate Class Night Mode SN (10 °C - 32 °C)'. No manufacturer in the survey publishes a compressor duty cycle."},"default_hours_per_day":24,"hours_note":"The Ah/24h figure is already a daily total, so the 24 h is only the appliance being switched on. It is not a compressor run-time.","sources":[{"field_group":"figures.ah_per_24h","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Average Ampere Usage** (Ah/24h) 37.0","clause":"T2120-C column","note":"Total Volume (L) 119; Volume freezer (L) 17. Table read with pdftotext; the T2120-C column value is 37.0."},{"field_group":"figures.test_standard","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"** According IEC62552-2020 part 3.","clause":"footnote to the Energy Consumption and Average Ampere Usage rows"},{"field_group":"figures.ambient_c","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"No ambient or interior temperature is stated for the Ah/24h figure; only the climate classes 'SN - T (10 °C - 43°C)' (day mode) and 'SN (10 °C - 32 °C)' (night mode) are given."}],"gaps":["figures.ambient_c"],"open_questions":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025)","source_url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.ambient_c","line":"No published statement found (checked 16 September 2026).","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf"}],"absence_by_gap":{"figures.ambient_c":"No published statement found (checked 16 September 2026)."},"source_hosts":["thetford.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#thetford-t2120-c","amps":1.5416666666666667,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"thetford-t2138-c","category":"compressor_fridge","brand":"Thetford","model":"T2138-C","name":"Thetford T2138-C 12V compressor refrigerator","generic_label":"12V compressor fridge, 138 litre class (Thetford T2138-C figure)","official_url":"https://www.thetford.com/","figures":{"ah_per_24h":40,"ambient_c":null,"interior_c":null,"test_standard":"IEC62552-2020 part 3"},"duty_cycle_published":false,"sizing":{"basis":"ah_per_24h","interlock":null,"blocking_notice":null,"note":"Thetford publishes a daily figure, 'Average Ampere Usage** (Ah/24h) 40.0', and is the only maker in the survey to name a test standard for it: '** According IEC62552-2020 part 3.' (printed that way; IEC 62552-3:2020). The sheet states no ambient or interior temperature alongside the figure; the test conditions live in the standard, which is not reproduced in the sheet. It also prints 'Energy Consumption ** (kWh/24h) 0.5'. Climate class is given in two modes: 'Climate Class Day mode SN-T (10 °C - 43°C)' and 'Climate Class Night Mode SN (10 °C - 32 °C)'. No manufacturer in the survey publishes a compressor duty cycle."},"default_hours_per_day":24,"hours_note":"The Ah/24h figure is already a daily total, so the 24 h is only the appliance being switched on. It is not a compressor run-time.","sources":[{"field_group":"figures.ah_per_24h","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Average Ampere Usage** (Ah/24h) 40.0","clause":"T2138-C column","note":"Total Volume (L) 138; Volume freezer (L) 11. Table read with pdftotext; the T2138-C column value is 40.0."},{"field_group":"figures.test_standard","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"** According IEC62552-2020 part 3.","clause":"footnote to the Energy Consumption and Average Ampere Usage rows"},{"field_group":"figures.ambient_c","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"No ambient or interior temperature is stated for the Ah/24h figure; only the climate classes 'SN-T (10 °C - 43°C)' (day mode) and 'SN (10 °C - 32 °C)' (night mode) are given."}],"gaps":["figures.ambient_c"],"open_questions":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025)","source_url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.ambient_c","line":"No published statement found (checked 16 September 2026).","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf"}],"absence_by_gap":{"figures.ambient_c":"No published statement found (checked 16 September 2026)."},"source_hosts":["thetford.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#thetford-t2138-c","amps":1.6666666666666667,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"thetford-t2152-c","category":"compressor_fridge","brand":"Thetford","model":"T2152-C","name":"Thetford T2152-C 12V compressor refrigerator","generic_label":"12V compressor fridge, 150 litre class (Thetford T2152-C figure)","official_url":"https://www.thetford.com/","figures":{"ah_per_24h":37.6,"ambient_c":null,"interior_c":null,"test_standard":"IEC62552-2020 part 3"},"duty_cycle_published":false,"sizing":{"basis":"ah_per_24h","interlock":null,"blocking_notice":null,"note":"Thetford publishes a daily figure, 'Average Ampere Usage** (Ah/24h) 37.6', and is the only maker in the survey to name a test standard for it: '** According IEC62552-2020 part 3.' (printed that way; IEC 62552-3:2020). The sheet states no ambient or interior temperature alongside the figure; the test conditions live in the standard, which is not reproduced in the sheet. It also prints 'Energy Consumption ** (kWh/24h) 0.47'. Climate class is given in two modes: 'Climate Class Day mode SN-T (10 °C - 43°C)' and 'Climate Class Night Mode SN (10 °C - 32 °C)'. No manufacturer in the survey publishes a compressor duty cycle."},"default_hours_per_day":24,"hours_note":"The Ah/24h figure is already a daily total, so the 24 h is only the appliance being switched on. It is not a compressor run-time.","sources":[{"field_group":"figures.ah_per_24h","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Average Ampere Usage** (Ah/24h) 37.6","clause":"T2152-C column","note":"Total Volume (L) 150; Volume freezer (L) 17. Table read with pdftotext; the T2152-C column value is 37.6."},{"field_group":"figures.test_standard","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"** According IEC62552-2020 part 3.","clause":"footnote to the Energy Consumption and Average Ampere Usage rows"},{"field_group":"figures.ambient_c","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"No ambient or interior temperature is stated for the Ah/24h figure; only the climate classes 'SN-T (10 °C - 43°C)' (day mode) and 'SN (10 °C - 32 °C)' (night mode) are given."}],"gaps":["figures.ambient_c"],"open_questions":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025)","source_url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.ambient_c","line":"No published statement found (checked 16 September 2026).","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf"}],"absence_by_gap":{"figures.ambient_c":"No published statement found (checked 16 September 2026)."},"source_hosts":["thetford.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#thetford-t2152-c","amps":1.5666666666666667,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"thetford-t2160-c","category":"compressor_fridge","brand":"Thetford","model":"T2160-C","name":"Thetford T2160-C 12V compressor refrigerator","generic_label":"12V compressor fridge, 158 litre class (Thetford T2160-C figure)","official_url":"https://www.thetford.com/","figures":{"ah_per_24h":44,"ambient_c":null,"interior_c":null,"test_standard":"IEC62552-2020 part 3"},"duty_cycle_published":false,"sizing":{"basis":"ah_per_24h","interlock":null,"blocking_notice":null,"note":"Thetford publishes a daily figure, 'Average Ampere Usage** (Ah/24h) 44.0', and is the only maker in the survey to name a test standard for it: '** According IEC62552-2020 part 3.' (printed that way; IEC 62552-3:2020). The sheet states no ambient or interior temperature alongside the figure; the test conditions live in the standard, which is not reproduced in the sheet. It also prints 'Energy Consumption ** (kWh/24h) 0.55'. Climate class is given in two modes: 'Climate Class Day mode SN-T (10 °C - 43°C)' and 'Climate Class Night Mode SN (10 °C - 32 °C)'. No manufacturer in the survey publishes a compressor duty cycle."},"default_hours_per_day":24,"hours_note":"The Ah/24h figure is already a daily total, so the 24 h is only the appliance being switched on. It is not a compressor run-time.","sources":[{"field_group":"figures.ah_per_24h","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Average Ampere Usage** (Ah/24h) 44.0","clause":"T2160-C column","note":"Total Volume (L) 158; Volume freezer (L) 31. Table read with pdftotext; the T2160-C column value is 44.0."},{"field_group":"figures.test_standard","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"** According IEC62552-2020 part 3.","clause":"footnote to the Energy Consumption and Average Ampere Usage rows"},{"field_group":"figures.ambient_c","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"No ambient or interior temperature is stated for the Ah/24h figure; only the climate classes 'SN-T (10 °C - 43°C)' (day mode) and 'SN (10 °C - 32 °C)' (night mode) are given."}],"gaps":["figures.ambient_c"],"open_questions":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025)","source_url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.ambient_c","line":"No published statement found (checked 16 September 2026).","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf"}],"absence_by_gap":{"figures.ambient_c":"No published statement found (checked 16 September 2026)."},"source_hosts":["thetford.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#thetford-t2160-c","amps":1.8333333333333333,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"thetford-t2175-c","category":"compressor_fridge","brand":"Thetford","model":"T2175-C","name":"Thetford T2175-C 12V compressor refrigerator","generic_label":"12V compressor fridge, 174 litre class (Thetford T2175-C figure)","official_url":"https://www.thetford.com/","figures":{"ah_per_24h":44.8,"ambient_c":null,"interior_c":null,"test_standard":"IEC62552-2020 part 3"},"duty_cycle_published":false,"sizing":{"basis":"ah_per_24h","interlock":null,"blocking_notice":null,"note":"Thetford publishes a daily figure, 'Average Ampere Usage** (Ah/24h) 44.8', and is the only maker in the survey to name a test standard for it: '** According IEC62552-2020 part 3.' (printed that way; IEC 62552-3:2020). The sheet states no ambient or interior temperature alongside the figure; the test conditions live in the standard, which is not reproduced in the sheet. It also prints 'Energy Consumption ** (kWh/24h) 0.56'. Climate class is given in two modes: 'Climate Class Day mode SN-T (10 °C - 43°C)' and 'Climate Class Night Mode SN (10 °C - 32 °C)'. No manufacturer in the survey publishes a compressor duty cycle."},"default_hours_per_day":24,"hours_note":"The Ah/24h figure is already a daily total, so the 24 h is only the appliance being switched on. It is not a compressor run-time.","sources":[{"field_group":"figures.ah_per_24h","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Average Ampere Usage** (Ah/24h) 44.8","clause":"T2175-C column","note":"Total Volume (L) 174; Volume freezer (L) 34. Table read with pdftotext; the T2175-C column value is 44.8."},{"field_group":"figures.test_standard","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"** According IEC62552-2020 part 3.","clause":"footnote to the Energy Consumption and Average Ampere Usage rows"},{"field_group":"figures.ambient_c","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","document_date":"2025-07","document_edition":"072025 (printed), 2026 range","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"No ambient or interior temperature is stated for the Ah/24h figure; only the climate classes 'SN-T (10 °C - 43°C)' (day mode) and 'SN (10 °C - 32 °C)' (night mode) are given."}],"gaps":["figures.ambient_c"],"open_questions":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025)","source_url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.ambient_c","line":"No published statement found (checked 16 September 2026).","document_title":"Thetford '12V Compressor refrigerators' product range sheet, 2026 range (7.1_Thetford_12V-Refrigerators_2026_EN_LR)","url":"https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf"}],"absence_by_gap":{"figures.ambient_c":"No published statement found (checked 16 September 2026)."},"source_hosts":["thetford.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#thetford-t2175-c","amps":1.8666666666666665,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"truma-combi-4","category":"gas_heater","brand":"Truma","model":"Combi 4","name":"Truma Combi 4 gas combination heater (12 V control side)","generic_label":"Gas combi heater with water heating, 4 kW (Truma Combi 4 figure)","official_url":"https://www.truma.com/gb/products/heating-systems-gb/combi-heaters/combi-4/","figures":{"average_a":1.2,"peak_a":6.5,"quiescent_a":0.001},"duty_cycle_published":false,"sizing":{"basis":"average_a","interlock":null,"blocking_notice":null,"note":"Truma publishes both a peak and an average: 'max. 6.5 A for short periods (average approx. 1.2 A)'. The 6.5 A peak sizes the cable and fuse; the 1.2 A average sizes the battery and is the only figure that reaches the Ah total. Quiescent current is 'approx. 1 mA'. No duty cycle is published."},"default_hours_per_day":6,"hours_note":"Heater run hours are the reader's assumption. Truma publishes no run-time or duty cycle.","sources":[{"field_group":"figures.average_a","url":"https://www.truma.com/gb/products/heating-systems-gb/combi-heaters/combi-4/","document_title":"Truma Combi 4 product page, 'Technical Details'","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Power consumption (at 12 V): operation of heater and water container max. 6.5 A for short periods (average approx. 1.2 A)","clause":"Technical Details"},{"field_group":"figures.peak_a","url":"https://www.truma.com/gb/products/heating-systems-gb/combi-heaters/combi-4/","document_title":"Truma Combi 4 product page, 'Technical Details'","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Power consumption (at 12 V): operation of heater and water container max. 6.5 A for short periods (average approx. 1.2 A)","clause":"Technical Details"},{"field_group":"figures.quiescent_a","url":"https://www.truma.com/gb/products/heating-systems-gb/combi-heaters/combi-4/","document_title":"Truma Combi 4 product page, 'Technical Details'","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Quiescent current approx. 1 mA","clause":"Technical Details"}],"gaps":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Truma Combi 4 product page (Technical Details)","source_url":"https://www.truma.com/gb/products/heating-systems-gb/combi-heaters/combi-4/","detected_by":"seed"}],"open_questions":[],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[],"absence_by_gap":{},"source_hosts":["truma.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#truma-combi-4","amps":1.2,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"truma-combi-d-6-e","category":"diesel_heater","brand":"Truma","model":"Combi D 6 E","name":"Truma Combi D 6 E diesel combination heater (12 V control side)","generic_label":"Diesel combi heater with water heating, 6 kW (Truma Combi D 6 E figure)","official_url":"https://www.truma.com/gb/products/heating-systems-gb/combi-heaters/combi-d-6-e/","figures":{"control_range_a":[1.8,4],"quiescent_a":0.001},"duty_cycle_published":false,"sizing":{"basis":"range_w","interlock":null,"blocking_notice":null,"note":"Truma publishes the 12 V draw as a range in amps, not watts: 'Power consumption (at 12 V): operation of heater and water container 1.8 – 4 A (in normal operation between \"Off\" and \"lowest operating level\" less than 1.8 A)'. The basis is the range (recorded in control_range_a); the answer is therefore a range. Quiescent current is 'approx. 1 mA'. No duty cycle is published."},"default_hours_per_day":6,"hours_note":"Heater run hours are the reader's assumption. Truma publishes no run-time or duty cycle.","sources":[{"field_group":"figures.control_range_a","url":"https://www.truma.com/gb/products/heating-systems-gb/combi-heaters/combi-d-6-e/","document_title":"Truma Combi D 6 E product page, 'Technical Details'","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Power consumption (at 12 V): operation of heater and water container 1.8 – 4 A (in normal operation between \"Off\" and \"lowest operating level\" less than 1.8 A)","clause":"Technical Details"},{"field_group":"figures.quiescent_a","url":"https://www.truma.com/gb/products/heating-systems-gb/combi-heaters/combi-d-6-e/","document_title":"Truma Combi D 6 E product page, 'Technical Details'","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Quiescent current approx. 1 mA","clause":"Technical Details"}],"gaps":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Truma Combi D 6 E product page (Technical Details)","source_url":"https://www.truma.com/gb/products/heating-systems-gb/combi-heaters/combi-d-6-e/","detected_by":"seed"}],"open_questions":[],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[],"absence_by_gap":{},"source_hosts":["truma.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#truma-combi-d-6-e","amps_range":[1.8,4],"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"victron-phoenix-12-1200-ve-direct","category":"inverter","brand":"Victron Energy","model":"Phoenix Inverter 12/1200 VE.Direct","name":"Victron Phoenix Inverter 12/1200 VE.Direct","generic_label":"1200 VA 12 V inverter (Victron Phoenix 12/1200 VE.Direct figures)","official_url":"https://www.victronenergy.com/inverters/phoenix-inverter-vedirect","figures":{"continuous_va":1200,"max_efficiency_pct":91,"zero_load_w":10,"eco_zero_load_w":1},"duty_cycle_published":false,"sizing":{"basis":"inverter","interlock":null,"blocking_notice":null,"note":"Victron publishes 'Max. efficiency' as a single maximum at one (unstated) load point and publishes no efficiency curve, so the checker cannot adjust efficiency for the reader's actual load; the maximum is the best case. 'Zero-load power' is the idle draw with the inverter on and nothing connected; 'Default zero-load power in ECO mode' applies only if ECO mode is enabled and the load stays below the ECO threshold (min load 15 W). The three values in each cell are the 12 / 24 / 48 V models. For the 12/1200 the 12 V column reads: max. efficiency 91%, zero-load 10 W, ECO zero-load 1 W; continuous power '1200VA' and '1000 / 850W' at 25 °C / 40 °C."},"default_hours_per_day":1,"hours_note":"Inverter hours are per 230 V load and are the reader's assumption; the checker applies the maximum efficiency to the reader's 230 V load and adds the zero-load draw for the hours the inverter is switched on. Victron publishes no usage pattern.","sources":[{"field_group":"figures.max_efficiency_pct","url":"https://www.victronenergy.com/upload/documents/Datasheet-Inverter-VE.Direct-250VA-1600VA-EN.pdf","document_title":"Victron Energy 'Inverters VE.Direct 250VA – 1600VA, 230V and 120V, 50Hz or 60Hz' datasheet","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Max. efficiency 91 / 91 / 92%","clause":"Specification table, 12/1200 24/1200 48/1200 column","note":"First value is the 12 V model. Datasheet carries no printed revision date."},{"field_group":"figures.zero_load_w","url":"https://www.victronenergy.com/upload/documents/Datasheet-Inverter-VE.Direct-250VA-1600VA-EN.pdf","document_title":"Victron Energy 'Inverters VE.Direct 250VA – 1600VA, 230V and 120V, 50Hz or 60Hz' datasheet","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Zero-load power 10 / 11 / 12W","clause":"Specification table, 12/1200 24/1200 48/1200 column"},{"field_group":"figures.eco_zero_load_w","url":"https://www.victronenergy.com/upload/documents/Datasheet-Inverter-VE.Direct-250VA-1600VA-EN.pdf","document_title":"Victron Energy 'Inverters VE.Direct 250VA – 1600VA, 230V and 120V, 50Hz or 60Hz' datasheet","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Default zero-load power in ECO mode (default retry interval: 2,5 s, adjustable) 1 / 1,5 / 3,0W","clause":"Specification table, 12/1200 24/1200 48/1200 column"},{"field_group":"figures.continuous_va","url":"https://www.victronenergy.com/upload/documents/Datasheet-Inverter-VE.Direct-250VA-1600VA-EN.pdf","document_title":"Victron Energy 'Inverters VE.Direct 250VA – 1600VA, 230V and 120V, 50Hz or 60Hz' datasheet","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Cont. power at 25°C (1) 1200VA; Cont. power at 25°C / 40°C 1000 / 850W","clause":"Specification table, 12/1200 24/1200 48/1200 column","note":"(1) Nonlinear load, crest factor 3:1"}],"gaps":[],"open_questions":["The 1200VA-1600VA datasheet URL in the checker spec returns 404; figures are taken from the combined 250VA–1600VA datasheet."],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Victron Inverters VE.Direct 250VA–1600VA datasheet","source_url":"https://www.victronenergy.com/upload/documents/Datasheet-Inverter-VE.Direct-250VA-1600VA-EN.pdf","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[],"absence_by_gap":{},"source_hosts":["victronenergy.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#victron-phoenix-12-1200-ve-direct","amps":null,"reader_entered":false,"is_inverter":true,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"victron-phoenix-12-500-ve-direct","category":"inverter","brand":"Victron Energy","model":"Phoenix Inverter 12/500 VE.Direct","name":"Victron Phoenix Inverter 12/500 VE.Direct","generic_label":"500 VA 12 V inverter (Victron Phoenix 12/500 VE.Direct figures)","official_url":"https://www.victronenergy.com/inverters/phoenix-inverter-vedirect","figures":{"continuous_va":500,"max_efficiency_pct":90,"zero_load_w":6,"eco_zero_load_w":1},"duty_cycle_published":false,"sizing":{"basis":"inverter","interlock":null,"blocking_notice":null,"note":"Victron publishes 'Max. efficiency' as a single maximum at one (unstated) load point and publishes no efficiency curve, so the checker cannot adjust efficiency for the reader's actual load; the maximum is the best case. 'Zero-load power' is the idle draw with the inverter on and nothing connected; 'Default zero-load power in ECO mode' applies only if ECO mode is enabled and the load stays below the ECO threshold (min load 15 W). The three values in each cell are the 12 / 24 / 48 V models. For the 12/500 the 12 V column reads: max. efficiency 90%, zero-load 6 W, ECO zero-load 1 W; continuous power '500VA' and '400 / 350W' at 25 °C / 40 °C."},"default_hours_per_day":1,"hours_note":"Inverter hours are per 230 V load and are the reader's assumption; the checker applies the maximum efficiency to the reader's 230 V load and adds the zero-load draw for the hours the inverter is switched on. Victron publishes no usage pattern.","sources":[{"field_group":"figures.max_efficiency_pct","url":"https://www.victronenergy.com/upload/documents/Datasheet-Inverter-VE.Direct-250VA-1600VA-EN.pdf","document_title":"Victron Energy 'Inverters VE.Direct 250VA – 1600VA, 230V and 120V, 50Hz or 60Hz' datasheet","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Max. efficiency 90 / 90 / 91%","clause":"Specification table, 12/500 24/500 48/500 column","note":"First value is the 12 V model. Datasheet carries no printed revision date."},{"field_group":"figures.zero_load_w","url":"https://www.victronenergy.com/upload/documents/Datasheet-Inverter-VE.Direct-250VA-1600VA-EN.pdf","document_title":"Victron Energy 'Inverters VE.Direct 250VA – 1600VA, 230V and 120V, 50Hz or 60Hz' datasheet","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Zero-load power 6 / 6,5 / 9W","clause":"Specification table, 12/500 24/500 48/500 column"},{"field_group":"figures.eco_zero_load_w","url":"https://www.victronenergy.com/upload/documents/Datasheet-Inverter-VE.Direct-250VA-1600VA-EN.pdf","document_title":"Victron Energy 'Inverters VE.Direct 250VA – 1600VA, 230V and 120V, 50Hz or 60Hz' datasheet","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Default zero-load power in ECO mode (default retry interval: 2,5 s, adjustable) 1 / 1,5 / 3,0W","clause":"Specification table, 12/500 24/500 48/500 column"},{"field_group":"figures.continuous_va","url":"https://www.victronenergy.com/upload/documents/Datasheet-Inverter-VE.Direct-250VA-1600VA-EN.pdf","document_title":"Victron Energy 'Inverters VE.Direct 250VA – 1600VA, 230V and 120V, 50Hz or 60Hz' datasheet","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Cont. power at 25°C (1) 500VA; Cont. power at 25°C / 40°C 400 / 350W","clause":"Specification table, 12/500 24/500 48/500 column","note":"(1) Nonlinear load, crest factor 3:1"}],"gaps":[],"open_questions":["The checker spec URL Datasheet-Phoenix-Inverter-VE.Direct-250VA-800VA-EN.pdf now serves the combined 250VA–1600VA datasheet; the 1200VA-1600VA URL returns 404. Both models are taken from the combined sheet."],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Victron Inverters VE.Direct 250VA–1600VA datasheet","source_url":"https://www.victronenergy.com/upload/documents/Datasheet-Inverter-VE.Direct-250VA-1600VA-EN.pdf","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[],"absence_by_gap":{},"source_hosts":["victronenergy.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#victron-phoenix-12-500-ve-direct","amps":null,"reader_entered":false,"is_inverter":true,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"vitrifrigo-c51i","category":"compressor_fridge","brand":"Vitrifrigo","model":"C51i CHR","name":"Vitrifrigo C51i CHR compressor fridge-freezer (consumption not published)","generic_label":"12V compressor fridge, 51 litre class (Vitrifrigo C51i; no maker consumption figure)","official_url":"https://www.vitrifrigo.com/en_en/fridge-freezer-c51i-chr-grey","figures":{"average_a":null,"ah_per_24h":null},"duty_cycle_published":false,"sizing":{"basis":"reader_entered","interlock":null,"blocking_notice":null,"note":"Vitrifrigo publishes no consumption figure for the C51i CHR: the datasheet's 'Absorption / Consumo' row is printed 'N.A.' and the product page's technical data lists only volume, dimensions, weight, thermostat, cooling unit and 'Supply 12/24 Vdc'. The reader must enter their own figure. A Vitrifrigo news article about the C51i HP variant reports a test result, not a specification; see open_questions."},"default_hours_per_day":24,"hours_note":"A fridge runs continuously; the 24 h is the appliance being switched on, not the compressor running. The compressor duty cycle is inside the maker's average figure and is not published separately.","sources":[{"field_group":"figures.average_a","url":"https://www.vitrifrigo.com/en_en/amfile/file/download/file/147/","document_title":"Vitrifrigo 'Chromelock Series C51i CHR' datasheet (C51i_CHR_data_sheet)","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"Row 'Absorption / Consumo' is printed 'N.A.'. Total volume 51 lt., freezer 3,6 lt., power supply 12/24 Vdc."},{"field_group":"figures.ah_per_24h","url":"https://www.vitrifrigo.com/en_en/fridge-freezer-c51i-chr-grey","document_title":"Vitrifrigo product page 'Fridge-freezer, C51i CHR, Grey', Technical data","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","absent":true,"note":"Technical data block lists no power, current, Wh or Ah figure."}],"gaps":["figures.average_a","figures.ah_per_24h"],"open_questions":["Vitrifrigo's news page 'Secop BD Nano Compressor Powers Vitrifrigo RV Refrigerator in Efficiency Test' (vitrifrigo.com/en_us/news/...) states for the C51i HP variant that 'Test results showed the system consumed 78 Wh over 24 hours' at 'approximately 40 °C' ambient. It is a case-study result for a different variant with no test standard named, so it is not recorded as a figure."],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Vitrifrigo C51i CHR datasheet and product page (absence recorded)","source_url":"https://www.vitrifrigo.com/en_en/amfile/file/download/file/147/","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.average_a","line":"No published 12 V current figure found (checked 16 September 2026).","document_title":"Vitrifrigo 'Chromelock Series C51i CHR' datasheet (C51i_CHR_data_sheet)","url":"https://www.vitrifrigo.com/en_en/amfile/file/download/file/147/"},{"gap":"figures.ah_per_24h","line":"No published daily consumption figure found (checked 16 September 2026).","document_title":"Vitrifrigo product page 'Fridge-freezer, C51i CHR, Grey', Technical data","url":"https://www.vitrifrigo.com/en_en/fridge-freezer-c51i-chr-grey"}],"absence_by_gap":{"figures.average_a":"No published 12 V current figure found (checked 16 September 2026).","figures.ah_per_24h":"No published daily consumption figure found (checked 16 September 2026)."},"source_hosts":[],"distributor_hosted":false,"evidence_grades":[],"anchor":"#vitrifrigo-c51i","amps":null,"reader_entered":true,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"webasto-air-top-2000-stc","category":"diesel_heater","brand":"Webasto","model":"Air Top 2000 STC","name":"Webasto Air Top 2000 STC diesel air heater (12 V)","generic_label":"2 kW diesel air heater (Webasto Air Top 2000 STC figure)","official_url":"https://www.webasto.com/en-int/heating/air-heater/air-top-2000-stc.html","figures":{"control_range_w":[15,30],"startup_w":75,"startup_duration_published":false},"duty_cycle_published":false,"sizing":{"basis":"range_w","interlock":null,"blocking_notice":null,"note":"Webasto publishes running consumption as a control range, 'Rated power consumption, control range (W) 15 – 30' for the 12 V diesel heater, so the answer is a range, not a point. The start-up figure, 'The Air Top 2000 STC requires 75 watts at 12 or 24 volts during start-up', is EXCLUDED from the Ah total because Webasto publishes no start-up duration: a wattage with no time cannot become amp-hours. Webasto's own two 2024 datasheets disagree on the lower bound for 12 V diesel (15 W in the product datasheet, 13 W in the RV-market datasheet); the product datasheet figure is used."},"default_hours_per_day":6,"hours_note":"Heater run hours are the reader's assumption. Webasto publishes no run-time or duty cycle; a thermostatically controlled heater cycles between the ends of its control range and the maker does not say how.","sources":[{"field_group":"figures.control_range_w","url":"https://www.webasto.com/content/dam/global-brand/business-fields/heating/air-heater/documents/240806_Datasheet_Air%20Top%202000_STC_EN.pdf.coredownload.inline.pdf","document_title":"Webasto 'Air Top 2000 STC – The simple and cost-effective solution' datasheet (07/24)","document_date":"2024-07","document_edition":"07/24","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Rated power consumption, control range (W) 15 – 30 13 – 28 15 – 30","clause":"Technical specifications table","note":"Three columns: Diesel 12 V / Diesel 24 V / Gasoline 12 V ('Rated voltage (V) 12 24 12'). The 12 V diesel value is 15 – 30 W."},{"field_group":"figures.control_range_w","url":"https://www.webasto.com/content/dam/global-brand/business-fields/heating/air-heater/documents/240813_Datasheet_AirTopSerie_RecreationalVehicles_EN.pdf.coredownload.inline.pdf","document_title":"Webasto 'Air heaters for the RV market – Air Top 2000 STC and Air Top Evo 40 / 55' datasheet (08/24)","document_date":"2024-08","document_edition":"08/24","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Rated power consumption (W) 13 – 30 15 – 30 15 – 40 / 55* 15 – 95 / 130**","clause":"Technical Specifications table","note":"Columns: Air Top 2000 STC diesel / Air Top 2000 STC gasoline / Evo 40 / Evo 55. Gives 13 – 30 W for the diesel STC, disagreeing with the product datasheet's 15 – 30 W. Recorded as an edition disagreement, not used as the figure."},{"field_group":"figures.startup_w","url":"https://cdn.shopify.com/s/files/1/0510/2800/0922/files/webasto-airtop-2000-stc-installation-manual.pdf","document_title":"Webasto 'Air Heater Air Top 2000 STC B (Gasoline) / Air Top 2000 STC D (Diesel) Installation Manual' (P/N 5012634C, Org. 08/2017 Rev. 11/2021, www.webasto.us)","document_date":"2021-11","document_edition":"P/N 5012634C, Org. 08/2017 Rev. 11/2021","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"other","quote":"The Air Top 2000 STC requires 75 watts at 12 or 24 volts during start-up.","clause":"Electrical connections","note":"Webasto US (webasto.us) installation manual read on a retailer's Shopify CDN copy; flagged for re-sourcing on a Webasto domain. The European instructions 'Installation Instructions Air Top 2000 STC' (Webasto Thermo & Comfort SE, Ident No. 9043156A, 11/2022, read on butlertechnik.com) contain no start-up power figure. The checker spec cited revision 5012634E; the copy read is 5012634C."},{"field_group":"figures.startup_duration_published","url":"https://cdn.shopify.com/s/files/1/0510/2800/0922/files/webasto-airtop-2000-stc-installation-manual.pdf","document_title":"Webasto 'Air Heater Air Top 2000 STC B (Gasoline) / Air Top 2000 STC D (Diesel) Installation Manual' (P/N 5012634C, Org. 08/2017 Rev. 11/2021, www.webasto.us)","document_date":"2021-11","document_edition":"P/N 5012634C, Org. 08/2017 Rev. 11/2021","checked":"2026-09-16","evidence":"manufacturer","hosted_by":"other","absent":true,"note":"The manual gives the start-up wattage but no duration of the start-up phase; the datasheets give none either."}],"gaps":["figures.startup_duration_published"],"open_questions":["Webasto's 07/24 product datasheet gives 15 – 30 W and its 08/24 RV-market datasheet gives 13 – 30 W for the 12 V diesel Air Top 2000 STC. Which is current is unresolved; the product datasheet is used.","Re-source the 75 W start-up statement (P/N 5012634) on webasto.us or techwebasto.com; on 2026-09-16 it was only readable on a retailer's Shopify copy. The checker spec's eima.it and btrac.com copies were not used because the webasto.com datasheet was readable."],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Webasto Air Top 2000 STC datasheet (07/24) and the Webasto US installation manual P/N 5012634C","source_url":"https://www.webasto.com/content/dam/global-brand/business-fields/heating/air-heater/documents/240806_Datasheet_Air%20Top%202000_STC_EN.pdf.coredownload.inline.pdf","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[{"gap":"figures.startup_duration_published","line":"No published statement found (checked 16 September 2026).","document_title":"Webasto 'Air Heater Air Top 2000 STC B (Gasoline) / Air Top 2000 STC D (Diesel) Installation Manual' (P/N 5012634C, Org. 08/2017 Rev. 11/2021, www.webasto.us)","url":"https://cdn.shopify.com/s/files/1/0510/2800/0922/files/webasto-airtop-2000-stc-installation-manual.pdf"}],"absence_by_gap":{"figures.startup_duration_published":"No published statement found (checked 16 September 2026)."},"source_hosts":["webasto.com","cdn.shopify.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#webasto-air-top-2000-stc","amps_range":[1.25,2.5],"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":true},{"id":"whale-gp1352-premium-submersible","category":"water_pump","brand":"Whale","model":"Premium Submersible Pump GP1352","name":"Whale Premium submersible pump GP1352, 12 V","generic_label":"12V submersible water pump, 13 l/min class (Whale GP1352 figure)","official_url":"https://whale.navico.com/caravan-motorhome/water-pumps/","figures":{"average_a":3.6,"amps_vs_head":[{"head_m":0,"amps":3.6,"litres_per_min":13.2},{"head_m":1,"amps":3.3,"litres_per_min":11.7},{"head_m":3,"amps":2.9,"litres_per_min":9.7}]},"duty_cycle_published":false,"sizing":{"basis":"average_a","interlock":null,"blocking_notice":null,"note":"Whale publishes current draw at three discharge heads (0 m 3.6 A, 1 m 3.3 A, 3 m 2.9 A) rather than an average. The checker uses the 0 m figure, 3.6 A, as the upper point; the figure in average_a is that published 0 m point, not a maker's average. The same catalogue page gives the Standard GP1002 as 2.4 / 2.2 / 2.0 A and the High Flow GP1652 as 3.8 / 3.7 / 3.5 A."},"default_hours_per_day":0.33,"hours_note":"No pump maker in the survey publishes run minutes per day. The default of 0.33 h (20 minutes) is the reader's assumption and should be replaced with their own estimate.","sources":[{"field_group":"figures.amps_vs_head","url":"https://docs.navico.com/view/178041564/12","document_title":"Whale RV Catalogue (Navico Group), page 12, 'Submersible Pump Range'","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Performance PART NUMBER GP1002 GP1352 GP1354 GP1652 Max Discharge Head Flow rate / Current draw at 12V d.c. 0 m (0ft) 10.3 ltrs/min (2.4 amps) 13.2 ltrs/min (3.6 amps) 15.8 ltrs/min (3.8 amps) 1 m (3ft) 8.0 ltrs/min (2.2 amps) 11.7 ltrs/min (3.3 amps) 14.8 ltrs/min (3.7 amps) 3 m (9ft) 5.7 ltrs/min (2.0 amps) 9.7 ltrs/min (2.9 amps) 12.8 ltrs/min (3.5 amps)","clause":"page 12, Performance table","note":"Whale is a Navico Group brand; whale.navico.com links to this catalogue on docs.navico.com. The catalogue carries no printed edition date on the page. Columns: GP1002 Standard 12 V / GP1352 Premium 12 V (GP1354 is the 24 V version) / GP1652 High Flow 12 V."},{"field_group":"figures.average_a","url":"https://docs.navico.com/view/178041564/12","document_title":"Whale RV Catalogue (Navico Group), page 12, 'Submersible Pump Range'","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"13.2 ltrs/min (3.6 amps)","clause":"page 12, Performance table, GP1352 column, 0 m (0ft) row","note":"The 0 m head point, the highest current Whale publishes for this pump. Not a maker's average."}],"gaps":[],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Whale RV Catalogue page 12 (Submersible Pump Range)","source_url":"https://docs.navico.com/view/178041564/12","detected_by":"seed"}],"open_questions":[],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[],"absence_by_gap":{},"source_hosts":["docs.navico.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#whale-gp1352-premium-submersible","amps":3.6,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false},{"id":"whale-watermaster-ep1612","category":"water_pump","brand":"Whale","model":"Watermaster Exterior Water Pump EP1612 (also EP1622, EP1642)","name":"Whale Watermaster exterior water pump EP1612, 12 V","generic_label":"12V submersible water pump assembly, 15 l/min class (Whale Watermaster EP1612 figure)","official_url":"https://whale.navico.com/caravan-motorhome/water-pumps/","figures":{"average_a":3.8,"amps_vs_head":[{"head_m":0,"amps":3.8,"litres_per_min":15.8},{"head_m":1,"amps":3.7,"litres_per_min":14.8},{"head_m":3,"amps":3.5,"litres_per_min":12.8}]},"duty_cycle_published":false,"sizing":{"basis":"average_a","interlock":null,"blocking_notice":null,"note":"Whale publishes current draw at three discharge heads (0 m 3.8 A, 1 m 3.7 A, 3 m 3.5 A) rather than an average. The checker uses the 0 m figure, 3.8 A, as the upper point; the figure in average_a is that published 0 m point, not a maker's average. Whale adds: 'Pump performance may vary depending on the plumbing system and restrictions on outlets in your leisure vehicle.' The EP1652 named in the checker spec does not appear in the current catalogue."},"default_hours_per_day":0.33,"hours_note":"No pump maker in the survey publishes run minutes per day. The default of 0.33 h (20 minutes) is the reader's assumption and should be replaced with their own estimate.","sources":[{"field_group":"figures.amps_vs_head","url":"https://docs.navico.com/view/178041564/16","document_title":"Whale RV Catalogue (Navico Group), page 16, 'Watermaster Exterior Water Pump Range'","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"Performance PART NUMBER EP1612, EP1622, EP1642 Max Discharge Head Flow rate / Current draw at 12V d.c. 0 m (0ft) 15.8 ltrs/min (3.8 amps) 1 m (3ft) 14.8 ltrs/min (3.7 amps) 3 m (9ft) 12.8 ltrs/min (3.5 amps)","clause":"page 16, Performance table","note":"Whale is a Navico Group brand; whale.navico.com links to this catalogue on docs.navico.com. The catalogue carries no printed edition date on the page."},{"field_group":"figures.average_a","url":"https://docs.navico.com/view/178041564/16","document_title":"Whale RV Catalogue (Navico Group), page 16, 'Watermaster Exterior Water Pump Range'","document_date":null,"document_edition":null,"checked":"2026-09-16","evidence":"manufacturer","hosted_by":"manufacturer","quote":"0 m (0ft) 15.8 ltrs/min (3.8 amps)","clause":"page 16, Performance table","note":"The 0 m head point, the highest current Whale publishes for this pump. Not a maker's average."}],"gaps":[],"open_questions":["The checker spec named EP1652 with figures 3.6 / 3.3 / 2.9 A; those figures belong to the GP1352 Premium submersible pump in Whale's catalogue (page 12), recorded separately. EP1652 is not in the current Whale RV Catalogue."],"changelog":[{"date":"2026-09-16","field":"seed","new":"record created from the Whale RV Catalogue page 16 (Watermaster Exterior Water Pump Range)","source_url":"https://docs.navico.com/view/178041564/16","detected_by":"seed"}],"retailers":[],"last_reviewed":"2026-09-16","type":"appliances","first_checked":"2026-09-16","last_checked":"2026-09-16","age_days":1,"stale":false,"unverified":false,"freshness":"verified","freshness_label":"verified 16 September 2026","absences":[],"absence_by_gap":{},"source_hosts":["docs.navico.com"],"distributor_hosted":false,"evidence_grades":["manufacturer"],"anchor":"#whale-watermaster-ep1612","amps":3.8,"reader_entered":false,"is_inverter":false,"has_interlock":false,"has_blocking_notice":false,"startup_excluded":false}]}