Changelog
Every dated change to every record, newest first. Each entry names the field, the new value, the source and how the change was detected (seed, recheck, user tip, correction or manufacturer change). RSS: /changelog.xml.
Site
- 20 September 2026: corrected shared appliance validation, made battery sizing explicitly energy-only without discharge-rate correction, and separated published temperature points, interpolation and operating limits. Unsupported discharge temperatures produce no capacity recommendation.
- 20 September 2026: separated charge output from alternator input, restored recommended C-rate guidance and the Renogy C2 rating, separated source age from verification, restored calculator notices, and clarified privacy and the unavailable correction-email route.
- 16 September 2026: research and source verification for the first three pages: the battery size checker, the split charge relay or DC-DC charger decision, and mains chargers by published profile. Cable sizing and fuse sizing deliberately withheld pending BS EN 1648.
- 5 November 2026: build. A build date is not a verification date.
Records
| Date | Record | Field | Change | Source | Detected by |
|---|---|---|---|---|---|
| 4 November 2026 | Banner Energy Bull 955 51 (batteries) | ncc | was: listed: true, class C, NCC/VB/C/032, 72 Ah, 200 cycles at 50% DoD, list 2023-10 (https://www.thencc.org.uk/media/xtbduhos/class-c-batteries.pdf) listed: false; class, reference, capacity, cycles, list date and list URL set to null. Not on the NCC register dashboard (Class A 106 rows, Class B 58 rows, Class C 94 rows) read 2026-11-04; the NCC page says the dashboard holds "verified batteries currently on our register". The October 2023 and March 2024 list entries stay as dated source entries. | lookerstudio.google.com | recheck |
| 4 November 2026 | Banner Energy Bull 955 51 (batteries) | summary | was: Flooded leisure battery in Banner's D26/MO60 box. The Banner Energy Bull brochure gives 55 Ah (5 h), 72 Ah (20 h) and 85 Ah (100 h). Not on Banner's EN product listing on 2026-09-16. NCC Class C (Oct 2023 list: 72 Ah, 200 cycles at 50% DoD). Flooded leisure battery in Banner's D26/MO60 box. The Banner Energy Bull brochure gives 55 Ah (5 h), 72 Ah (20 h) and 85 Ah (100 h). Not on Banner's EN product listing on 2026-11-04. Listed NCC Class C in the Oct 2023 list (72 Ah, 200 cycles at 50% DoD); not on the NCC register dashboard read 2026-11-04. | lookerstudio.google.com | recheck |
| 4 November 2026 | Banner Energy Bull 955 51 (batteries) | sources.checked | Re-read 4 November 2026: Banner Energy Bull brochure file=455 (undated), Banner UK brochure 05/16 (Tayna-hosted), Banner battery-knowledge page, NCC October 2023 Class C and March 2024 lists, NCC register dashboard; every quoted capacity, cycle, DoD, dimension and weight figure confirmed unchanged. | recheck | |
| 4 November 2026 | Banner Energy Bull 957 51 (batteries) | capacity_ratings[*].temp_c | was: 25 (C5, C20, C100) null. The data sheet's footnote ¹) "All the listed values relate to room temperature +25° C" is attached to the "Maintenance ¹)" heading, not to "Rated capacity 75 Ah(K5), 100 Ah(K20), 110 Ah(K100)"; no capacity test temperature is stated. | bannerbatterien.com | correction |
| 4 November 2026 | Banner Energy Bull 957 51 (batteries) | retailers[alpha-batteries].price_gbp | was: 149.98 159.98 (Alpha Batteries page, "£ 159.98 Including VAT & Standard Delivery", 2026-11-04) | alpha-batteries.co.uk | recheck |
| 4 November 2026 | Banner Energy Bull 957 51 (batteries) | sources.checked | Re-read 4 November 2026: Technical Data Sheet DBTBAT00339 (2020-09-30, file=4710, still the sheet linked from the product page), product page, brochure file=455, battery-knowledge page, NCC October 2023 Class B and March 2024 lists; NCC register dashboard (Class B) added as a source. Capacity, charging voltage, cycle, DoD, dimension and weight figures confirmed unchanged apart from the temp_c correction. | recheck | |
| 4 November 2026 | Banner Energy Bull 959 01 (batteries) | retailers[tayna].price_gbp | was: 232.37 230.04 (Tayna page price, 2026-11-04) | tayna.co.uk | recheck |
| 4 November 2026 | Banner Energy Bull 959 01 (batteries) | sources.checked | Re-read 4 November 2026: Banner Energy Bull brochure file=455 (undated), Banner UK brochure 05/16 (Tayna-hosted), battery-knowledge page, NCC October 2023 Class B and March 2024 lists; NCC register dashboard (Class B) added as a source. Every quoted capacity, cycle, DoD, dimension and weight figure confirmed unchanged. | recheck | |
| 4 November 2026 | Banner Energy Bull 968 01 (batteries) | capacity_ratings[*].temp_c | was: 25 (C5, C20, C100) null. The data sheet's footnote ¹) "All the listed values relate to room temperature +25° C" is attached to the "Maintenance ¹)" heading, not to "Rated capacity 180 Ah(K5), 230 Ah(K20), 250 Ah(K100)"; no capacity test temperature is stated. | bannerbatterien.com | correction |
| 4 November 2026 | Banner Energy Bull 968 01 (batteries) | sources.checked | Re-read 4 November 2026: Technical Data Sheet file=4714 (prints "Document DBTBAT00339 prepared on 2020-09-30", still the sheet linked from the product page), product page, brochure file=455, battery-knowledge page, NCC October 2023 Class B and March 2024 lists; NCC register dashboard (Class B) added as a source. Capacity, charging voltage, cycle, DoD, dimension and weight figures confirmed unchanged apart from the temp_c correction. | recheck | |
| 4 November 2026 | CBE CB522-LT (chargerEvidence) | sources.checked | Re-read 4 November 2026 from the distributor copy (ed. 04/2019 cod. 000241a Rev.00): 22A, Max 14,5V, absorption max 1h (30 min with I<5A), float 13,5V max 240h, restart below 12,7V, refresh 14,5V max 30 min or I<5A, charging current limited to 10A at battery temperature < 0°C and 5A < -20°C, room temperature 0 - +40 °C. All confirmed unchanged. The CBE endpoint returned HTTP 500; its read date stays 2026-09-20. | campinglanghans.de | recheck |
| 4 November 2026 | CBE MP2USBC double USB charging socket (USB-A + USB-C), 12 V input (appliances) | sources.checked | Re-read 4 November 2026: CBE MP2USBC product page (the cbe.it URL now redirects to https://www.alko-tech.com/en/products/usb-c-double-charging-socket-mp2usbc_pdt_5509, AL-KO VT); '5V/3A USB-A + 5V/3A USB-C double charging socket (Input 12V)' confirmed unchanged; no 12 V input current or standby figure. | recheck | |
| 4 November 2026 | Citroen Relay (Jumper) (vehicles) | sources | was: Could not be read (DNS failure) on 2026-09-16: https://business.citroen.co.uk/commercial-vehicles/vans/citroen-relay/vehicle-handbook; could not be read (403): https://www.citroen.co.uk/models/new-relay-van.html. Added an absence entry for https://www.citroen.co.uk/models/new-relay-van.html, read on 2026-11-04 (403 on 2026-09-16): no alternator or charging wording. | citroen.co.uk | recheck |
| 4 November 2026 | Citroen Relay (Jumper) (vehicles) | sources.checked | Re-read 4 November 2026: Citroen Relay/Jumper handbook eGuide ed01-21 en-GB (document 9999_9999_369); regenerative-braking text still refers to the electric version's traction battery; no diesel alternator-control or leisure-battery wording; absences re-dated. | recheck | |
| 4 November 2026 | CTEK CS ONE (Gen 2) (chargers) | open_questions | was: Manual also warns: 'Do not use SUPPLY on deeply discharged lithium (LiFePO4)' and 'Do not use WAKE UP on deeply discharged lithium (LiFePO4)' (text truncated in extraction); read the full sentences on re-source. Answered from the same manual: both full warnings added as chemistry_mismatch_warning sources ('...batteries that do not have a Battery Management System.'); question removed. | ctek.com | recheck |
| 4 November 2026 | CTEK CS ONE (Gen 2) (chargers) | sources.checked | Re-read 4 November 2026: CS ONE (GEN 2) product sheet (© CTEK SWEDEN AB, 2025 | EN), user manual (model 2010, multilingual, footer 50030161D) and UK product page (£199.90 GBP); output 12 V 8.0 A, battery types, temperature compensation and IP65 confirmed unchanged. | ctek.com | recheck |
| 4 November 2026 | CTEK D250SE dual input 20A DC-DC charger with MPPT (dcdc) | engine_detection_thresholds | was: null (absence entry: 'The manual describes engine-running detection but states no voltage thresholds in the sections read.') Conventional alternator cut-in >13.1V, 5 sec; cut-out <12.8V, 10 sec; Smart alternator cut-in >11.8V, 5 sec; cut-out <11.4V, 10 sec, from the manual's TECHNICAL SPECIFICATION table; gap removed | ctek.com | correction |
| 4 November 2026 | CTEK D250SE dual input 20A DC-DC charger with MPPT (dcdc) | manufacturer_cable_fuse_table.wording | was: Cable sizes by cable length and a fuse rating, transcribed from the maker's table (values not repeated here) CABLE AND FUSE REQUIREMENTS (table heading only). Cable and fuse values removed from manufacturer_cable_fuse_table.wording and from the source quote. Link unchanged: still the maker's own manual. | ctek.com | correction |
| 4 November 2026 | CTEK D250SE dual input 20A DC-DC charger with MPPT (dcdc) | sources.quote | was: INPUT 11.5-23 V, 25 A; Selectable AGM option - 14.4V or 14.7V INPUT 11.5–23 V, 25 A; Selectable AGM option – 14.4V or 14.7V (en dash as printed; figures unchanged) | ctek.com | correction |
| 4 November 2026 | CTEK D250SE dual input 20A DC-DC charger with MPPT (dcdc) | sources.checked | Re-read 4 November 2026: D250SE product sheet (CTEK SWEDEN AB, 2024 | EN), D250SE & SMARTPASS 120S user manual (UK-EN, no edition printed), ctek.com/products/d250se, 12 Volt Planet (£257.00 seen). Output 20 A, input 11.5–23 V / 25 A, 14.4/14.7 V lead-acid and 14.2 V LiFePO4 confirmed unchanged. | recheck | |
| 4 November 2026 | CTEK LITHIUM XS (chargers) | profiles[lifepo4].absorption_v | was: 14.4 13.8 — the manual's CHARGING PROGRAM table labels step 3 'ABSORPTION Declining current 13.8V'; 14.4V is step 6 'MAXIMIZATION Max 14.4V'. 14.4V is kept in the wording. | ctek.com | correction |
| 4 November 2026 | CTEK LITHIUM XS (chargers) | sources.checked | Re-read 4 November 2026: LITHIUM XS manual (UK-EN, 20018043B, model 1081) and UK product page (£109.90 GBP); 5A max, 8 step, IP65, 13.8/14.4 VDC charging voltage and FLOAT 13.6V confirmed. | ctek.com | recheck |
| 4 November 2026 | CTEK MXS 10 (chargers) | sources[profiles].quote | was: a Recond mode for restoring and reconditioning stratified and deeply discharged batteries, a winter program for charging in cold weather and an AGM option a Recond mode for restoring and reconditioning stratified and deeply discharged batteries and an AGM option which maximises the performance life of most Stop/Start batteries (UK product page, 4 November 2026; the 'winter program' wording is no longer on the page) | ctek.com | manufacturer_change |
| 4 November 2026 | CTEK MXS 10 (chargers) | temp_sensor | was: optional_external unstated: the product page says only 'The MXS 10 also has a temperature sensor for optimised charging'; it does not say the sensor is external or optional. temperature_compensation stays true. | ctek.com | correction |
| 4 November 2026 | CTEK MXS 10 (chargers) | sources.checked | Re-read 4 November 2026: MXS 10 UK product page (£179.90 GBP); output 14.4/14.7/15.8/13.6 V, 10 A, 8 step, battery types WET, MF, Ca/Ca, AGM, GEL and IP65 confirmed. The manual safety file returns 404; its source keeps the 2026-09-16 date. | ctek.com | recheck |
| 4 November 2026 | CTEK MXS 5.0 (chargers) | sources[*].url | was: https://ctek.com/cdn/shop/files/MXS_5.0-manual-low-UK-EN.pdf Re-cited to the current multilingual manual, edition 50031744A (model number 1075, © Copyright CTEK Sweden AB 2025), linked from the UK product page; the UK-EN PDF returns 404. Output 5A max, 8 step, 14.4/14.7/15.8V and IP65 confirmed in the new edition. | ctek.com | manufacturer_change |
| 4 November 2026 | CTEK MXS 5.0 (chargers) | temperature_compensation | was: null (absent in the UK-EN manual) true, temp_sensor built_in: 'TEMPERATURE COMPENSATION Built in charge voltage compensation according to ambient temperature.' (edition 50031744A; also on the UK product page) | ctek.com | manufacturer_change |
| 4 November 2026 | CTEK MXS 5.0 (chargers) | profiles[efb] | Added: published, voltages null. 'All types of 12V lead-acid batteries (WET, MF, Ca/Ca, EFB, AGM and GEL)' (edition 50031744A). | ctek.com | manufacturer_change |
| 4 November 2026 | CTEK MXS 5.0 (chargers) | chemistry_mismatch_warning | was: The charger is designed for charging only for batteries according to the technical specification. Do not use the charger for any other purpose. Always follow battery manufacturers recommendations. The charger is only designed for charging batteries according to the technical specification. Do not use the charger for any other purpose. Always follow battery manufacturers’ user and safety recommendations (edition 50031744A); RECOND warning for GEL or AGM added as a source. | ctek.com | manufacturer_change |
| 4 November 2026 | CTEK MXS 5.0 (chargers) | open_questions | was: Record the edition code when a dated copy is found. Answered: current edition 50031744A, © 2025. Replaced by a could-not-be-re-read note for the 404 UK-EN edition that still carries FLOAT 13.6V. | ctek.com | recheck |
| 4 November 2026 | CTEK MXS 5.0 (chargers) | sources.checked | Re-read 4 November 2026: MXS 5.0 multilingual manual 50031744A (new edition) and UK product page (£89.90 GBP). The UK-EN manual (404) could not be re-read; its two profile sources keep the 2026-09-16 date. | ctek.com | recheck |
| 4 November 2026 | CTEK MXS 5.0 (chargers) | profiles[efb].wording | was: BATTERY TYPES All types of 12V lead-acid batteries (WET, MF, Ca/Ca, EFB, AGM and GEL) — 2025 edition; no program is assigned to EFB by name. Wording reduced to the 2025 manual’s own words (it renders inside quotation marks); the note that no program is assigned to EFB by name stays in the changelog and notes, not inside the quote. | ctek.com | correction |
| 4 November 2026 | Dometic CoolMatic CRX 50 compressor fridge (appliances) | sources[figures.ah_per_h].quote | was: Current consumption at 12 V: 1.1 Ah/h at +25 °C ambient temperature, 1.7 Ah/h at +32 °C ambient temperature, both at +5 °C interior temperature Current consumption at 12 V 1.1 Ah/h at +25 °C ambient temperature, 1.7 Ah/h at +32 °C ambient temperature, both at +5 °C interior temperature (the catalogue prints no colon after "12 V"; table label and cell joined as printed, page 118) | metris.hr | correction |
| 4 November 2026 | Dometic CoolMatic CRX 50 compressor fridge (appliances) | sizing.interlock | was: Dometic's CRX 50 installation and operating manual publishes 'Rated current 12 V⎓: 5.0 A'. That is the current while the compressor runs, about 4.5 times the catalogue average of 1.1 Ah/h. This checker uses the catalogue average and never lets the 5.0 A figure reach the daily total. Calculators seeded from the manual will tell you to buy a bank roughly four times too big. Dometic's CRX 50 installation and operating manual publishes 'Rated current 12 V⎓: 5.0 A'. The manual calls it rated current; it does not say the figure is an average or define it further. It is about 4.5 times the catalogue average of 1.1 Ah/h. This checker uses the catalogue average and never lets the 5.0 A figure reach the daily total. Calculators seeded from the manual will tell you to buy a bank roughly four times too big. (reworded: manual 4445102664, 13 Technical data, labels the figure only 'Rated current'; it does not say 'compressor-running'. The rated_a source note is reworded the same way.) | media.dometic.com | correction |
| 4 November 2026 | Dometic CoolMatic CRX 50 compressor fridge (appliances) | figures.average_w | was: 40 removed from figures; the catalogue line 'Average power consumption 40 W' is kept as a sizing.note source. The catalogue states no supply voltage and Dometic's CRX series manual 4445102565 prints 40 W as 'Power consumption (AC) (ACDC models only)'. The field is read as a 12 V draw (W ÷ 12) by deriveAppliance and checker.js only when the basis is average_a; this record's basis is ah_per_h, so no checker output changes. | metris.hr | correction |
| 4 November 2026 | Dometic CoolMatic CRX 50 compressor fridge (appliances) | sources.checked | Re-read 4 November 2026: Dometic catalogue section 4.24 page 118 (metris.hr copy, no printed year) and manual 4445102664 (08/2020); 1.1 / 1.7 Ah/h and 'Rated current 12 V⎓: 5.0 A' confirmed unchanged; test standard still absent. | recheck | |
| 4 November 2026 | Dometic CoolMatic CRX 65 compressor fridge (appliances) | sizing.interlock | was: Dometic's CRX 65 installation and operating manual publishes 'Rated current 12 V⎓: 5.5 A'. That is the current while the compressor runs, about 4.8 times the catalogue average of 1.14 Ah/h. This checker uses the catalogue average and never lets the 5.5 A figure reach the daily total. Calculators seeded from the manual will tell you to buy a bank roughly four times too big. Dometic's CRX 65 installation and operating manual publishes 'Rated current 12 V⎓: 5.5 A'. The manual calls it rated current; it does not say the figure is an average or define it further. It is about 4.8 times the catalogue average of 1.14 Ah/h. This checker uses the catalogue average and never lets the 5.5 A figure reach the daily total. Calculators seeded from the manual will tell you to buy a bank roughly four times too big. (reworded: manual 4445102664, 13 Technical data, labels the figure only 'Rated current'; it does not say 'compressor-running'. The rated_a source note is reworded the same way.) | media.dometic.com | correction |
| 4 November 2026 | Dometic CoolMatic CRX 65 compressor fridge (appliances) | figures.average_w | was: 45 removed from figures; the catalogue line 'Average power consumption 45 W' is kept as a sizing.note source. The catalogue states no supply voltage and Dometic's CRX series manual 4445102565 prints 45 W as 'Power consumption (AC) (ACDC models only)'. The field is read as a 12 V draw (W ÷ 12) by deriveAppliance and checker.js only when the basis is average_a; this record's basis is ah_per_h, so no checker output changes. | metris.hr | correction |
| 4 November 2026 | Dometic CoolMatic CRX 65 compressor fridge (appliances) | sources.checked | Re-read 4 November 2026: Dometic catalogue section 4.24 page 118 (metris.hr copy, no printed year) and manual 4445102664 (08/2020); 1.14 / 1.8 Ah/h and 'Rated current 12 V⎓: 5.5 A' confirmed unchanged; test standard still absent. | recheck | |
| 4 November 2026 | Dometic CoolMatic CRX 80 compressor fridge (appliances) | sizing.interlock | was: Dometic's CRX 80 installation and operating manual publishes 'Rated current 12 V⎓: 5.6 A'. That is the current while the compressor runs, about 4.7 times the catalogue average of 1.19 Ah/h. This checker uses the catalogue average and never lets the 5.6 A figure reach the daily total. Calculators seeded from the manual will tell you to buy a bank roughly four times too big. Dometic's CRX 80 installation and operating manual publishes 'Rated current 12 V⎓: 5.6 A'. The manual calls it rated current; it does not say the figure is an average or define it further. It is about 4.7 times the catalogue average of 1.19 Ah/h. This checker uses the catalogue average and never lets the 5.6 A figure reach the daily total. Calculators seeded from the manual will tell you to buy a bank roughly four times too big. (reworded: manual 4445102565, 13 Technical data, labels the figure only 'Rated current'; it does not say 'compressor-running'. The rated_a source note is reworded the same way.) | media.dometic.com | correction |
| 4 November 2026 | Dometic CoolMatic CRX 80 compressor fridge (appliances) | figures.average_w | was: 48 removed from figures; the catalogue line 'Average power consumption 48 W' is kept as a sizing.note source. The catalogue states no supply voltage and Dometic's CRX series manual 4445102565 prints 48 W as 'Power consumption (AC) (ACDC models only)'. The field is read as a 12 V draw (W ÷ 12) by deriveAppliance and checker.js only when the basis is average_a; this record's basis is ah_per_h, so no checker output changes. | metris.hr | correction |
| 4 November 2026 | Dometic CoolMatic CRX 80 compressor fridge (appliances) | sources.checked | Re-read 4 November 2026: Dometic catalogue section 4.24 page 120 (metris.hr copy, no printed year) and manual 4445102565 (07/2020); 1.19 / 2.0 Ah/h and 'Rated current 12 V⎓: 5.6 A' confirmed unchanged; test standard still absent. | recheck | |
| 4 November 2026 | Dometic RM 5330 3-way absorption fridge on 12 V (appliances) | sources[figures.rated_w].quote | was: Power consumption: 120 W (12 V⎓) Connection values: 125 W (230 V~) 120 W (12 V⎓) 18.3 g/h (gas) (manual 4445102234, 13 Technical data: the 120 W is in the 'Connection values:' row, not the 'Power consumption:' row; figure 120 W unchanged) | media.dometic.com | correction |
| 4 November 2026 | Dometic RM 5330 3-way absorption fridge on 12 V (appliances) | sources[figures.ah_per_24h].quote | was: 240 Ah/24 h (12 V⎓) Power consumption: 2,5 kWh/24 h (230 V~) 240 Ah/24 h (12 V⎓) (row label added; figure 240 Ah/24 h unchanged) | media.dometic.com | correction |
| 4 November 2026 | Dometic RM 5330 3-way absorption fridge on 12 V (appliances) | sizing.note | was: Dometic publishes the 12 V heating element as '120 W (12 V⎓)' ... On 12 V the absorption unit runs the element continuously; there is no thermostat cycling in DC mode and no duty cycle to publish. 120 W described by the manual's own row label 'Connection values'; the continuous-running statement replaced by the manual's words 'In DC power mode, the refrigerator works without thermostatic control (permanent operation).' | media.dometic.com | correction |
| 4 November 2026 | Dometic RM 5330 3-way absorption fridge on 12 V (appliances) | sources.checked | Re-read 4 November 2026: Dometic RM5310/RM5330/RM5380 manual 4445102234 (2021-04-30), still the current upload on documents.dometic.com; 120 W (12 V⎓), 240 Ah/24 h (12 V⎓), the 2.2 DC notice and the absence of a test ambient confirmed unchanged. | recheck | |
| 4 November 2026 | Dometic RUA 5208X 3-way absorption fridge on 12 V (appliances) | sizing.note | was: On 12 V the absorption element runs continuously; there is no duty cycle to publish. Removed: manual 4445102445 does not say DC operation is continuous (that statement is in the RM 5330 manual, not this one). Note now records that the footnote asterisk sits on 'Power consumption*' and 'Gas consumption*', not on 'Energy consumption'. | media.dometic.com | correction |
| 4 November 2026 | Dometic RUA 5208X 3-way absorption fridge on 12 V (appliances) | sources.checked | Re-read 4 November 2026: Dometic RUA 5208X/6408X/8408X manual 4445102445 (2024-02-19); 175 W and 346 Ah/24 h at 12 V⎓, the 32 °C / 4 °C footnote and the DC notice confirmed unchanged (columns checked by text position). | recheck | |
| 4 November 2026 | Dometic RUA 6408X 3-way absorption fridge on 12 V (appliances) | sizing.note | was: On 12 V the absorption element runs continuously; there is no duty cycle to publish. Removed: manual 4445102445 does not say DC operation is continuous (that statement is in the RM 5330 manual, not this one). Note now records that the footnote asterisk sits on 'Power consumption*' and 'Gas consumption*', not on 'Energy consumption'. | media.dometic.com | correction |
| 4 November 2026 | Dometic RUA 6408X 3-way absorption fridge on 12 V (appliances) | sources.checked | Re-read 4 November 2026: Dometic RUA 5208X/6408X/8408X manual 4445102445 (2024-02-19); 275 W and 400 Ah/24 h at 12 V⎓, the 32 °C / 4 °C footnote and the DC notice confirmed unchanged (columns checked by text position). | recheck | |
| 4 November 2026 | Dometic RUA 8408X 3-way absorption fridge on 12 V (appliances) | sizing.note | was: On 12 V the absorption element runs continuously; there is no duty cycle to publish. Removed: manual 4445102445 does not say DC operation is continuous (that statement is in the RM 5330 manual, not this one). Note now records that the footnote asterisk sits on 'Power consumption*' and 'Gas consumption*', not on 'Energy consumption'. | media.dometic.com | correction |
| 4 November 2026 | Dometic RUA 8408X 3-way absorption fridge on 12 V (appliances) | sources.checked | Re-read 4 November 2026: Dometic RUA 5208X/6408X/8408X manual 4445102445 (2024-02-19); 275 W and 420 Ah/24 h at 12 V⎓, the 32 °C / 4 °C footnote and the DC notice confirmed unchanged (columns checked by text position). | recheck | |
| 4 November 2026 | Durite 0-727-10 12V 100A extra heavy duty make/break relay (relays) | sources.checked | Re-read 4 November 2026: Durite Technical Information Sheet 0-727-10 and the durite.co.uk product page; 100 amp (continuous), 180 amp (intermittant), excitation voltage 4.8 volt, coil dropout voltage 2.3 volt, coil current 0.34 amp confirmed unchanged. | recheck | |
| 4 November 2026 | Durite 0-727-23 12V 70/20A double contact split charge relay (relays) | sources.type.note | was: Page status shown as Discontinued. A make/break relay of this type is energised by a switched (ignition/charge-warning) feed rather than by sensing voltage; Durite states no cut-in or cut-out voltage. Page shows 'This product has been discontinued'. Durite's sheet gives 'Type Split charge relay' and states no cut-in or cut-out voltage. (removed a sentence on how such relays are energised, which was not from a Durite document) | durite.co.uk | correction |
| 4 November 2026 | Durite 0-727-23 12V 70/20A double contact split charge relay (relays) | sources.checked | Re-read 4 November 2026: Durite Technical Information Sheet 0-727-23 and the durite.co.uk product page (discontinued); 70 amp (pin 8), 20 amp (pin 4), 9 - 15 volt DC confirmed unchanged. | recheck | |
| 4 November 2026 | Durite 0-727-33 12V 140A voltage sensitive relay (relays) | sources.manufacturer_wiring_diagram_url.quote | was: Terminals See diagram Technical Drawing (not to scale). The old quote paired two cells from different rows: the sheet reads 'Terminals 2 x M6 (Max Torque 5 +/-1N.m)' and 'Dimensions See diagram'. The linked drawing is a dimensioned drawing, not a wiring diagram. | durite.co.uk | correction |
| 4 November 2026 | Durite 0-727-33 12V 140A voltage sensitive relay (relays) | sources.checked | Re-read 4 November 2026: Durite Technical Information Sheet 0-727-33 (undated), durite.co.uk product page, Simply Split Charge (£39.99 seen). 140 amp, cut-in 13.3 volt (±0.1 volt), cut-out 12.65 volt (±0.1 volt), cut-out time delay 5 seconds confirmed unchanged; no cut-in delay is published. | recheck | |
| 4 November 2026 | Durite 0-727-43 12V 200A Smart Programmable Voltage Sensitive Relay (relays) | sources.checked | Re-read 4 November 2026: leaflet 0-727-43-LEAF and the durite.co.uk product page; Maximum Current 200A, Nominal Voltage 12V, Maximum Voltage 16.5V, Standby Current 2mA and the smart-alternator sentence confirmed unchanged; no programme voltages and no lithium wording published. | recheck | |
| 4 November 2026 | Eberspächer Airtronic S2 D2L diesel air heater (12 V) (appliances) | sources[figures.startup_w].note | was: No start-up, ignition or glow-phase power figure and no duration appears in the technical data or the operating instructions. No start-up, ignition or glow-phase power figure appears in the technical data or the operating instructions. The operating description gives timings only: 'STARTING THE AIRTRONIC S2 After approx. 65 seconds the fuel delivery starts and the fuel - air mixture in the combustion chamber ignites. After the flame sensor has detected the flame, the glow plug is switched off after 60 seconds.' (corrected: the document does give glow-phase timings, though no start-up power) | eberspaecher-climate.com | correction |
| 4 November 2026 | Eberspächer Airtronic S2 D2L diesel air heater (12 V) (appliances) | sources.checked | Re-read 4 November 2026: Eberspächer Airtronic S2 & M2 technical documentation 29.2100.20.1046 Issue C; 'Electrical Power Consumption W 34' for the S2 Commercial D2L (12 V and 24 V) confirmed unchanged by table-mode extraction; start-up power still absent. | recheck | |
| 4 November 2026 | Exide Equipment GEL ES1200 (batteries) | charge.recommended_charge_current_c_rate | was: 0.25 null. The Exide Nordic datasheet says "We recommend the use of a charger with an output amps that is, a maximum, 25% of the battery's capacity (Ah figure)": a maximum, not a recommended charge current. The schema has no C-rate maximum field and an amp figure would be derived, so nothing is recorded; the wording stays in the charge source note. | akkupoint.ch | correction |
| 4 November 2026 | Exide Equipment GEL ES1200 (batteries) | sources | Added the Exide Marine & Leisure brochure (2026-09 upload, AXEMLBEPDF00224), now linked from the range page, as a capacity source; it repeats 110/120 Ah (20h) and the product-page dimensions. | exidegroup.com | manufacturer_change |
| 4 November 2026 | Exide Equipment GEL ES1200 (batteries) | sources.checked | Re-read 4 November 2026: ES1200 product page and Equipment GEL range page (browser), 2021 full range leaflet (still live), 2026-09 Marine & Leisure brochure, Exide Nordic datasheet (akkupoint.ch), NCC October 2023 Class A and March 2024 lists; NCC register dashboard (Class A) added as a source. Capacity, Wh, charge voltage, dimension and weight figures confirmed unchanged apart from the C-rate correction. | recheck | |
| 4 November 2026 | Exide Equipment GEL ES1300 (batteries) | charge.recommended_charge_current_c_rate | was: 0.25 null. The Exide Nordic datasheet says "We recommend the use of a charger with an output amps that is, a maximum, 25% of the battery's capacity (Ah figure)": a maximum, not a recommended charge current. The schema has no C-rate maximum field and an amp figure would be derived, so nothing is recorded; the wording stays in the charge source note. | akkupoint.ch | correction |
| 4 November 2026 | Exide Equipment GEL ES1300 (batteries) | sources | Added the Exide Marine & Leisure brochure (2026-09 upload, AXEMLBEPDF00224), now linked from the range page, as a capacity source; it repeats 110/120 Ah (20h) and the product-page dimensions. | exidegroup.com | manufacturer_change |
| 4 November 2026 | Exide Equipment GEL ES1300 (batteries) | sources.checked | Re-read 4 November 2026: ES1300 product page and Equipment GEL range page (browser), 2021 full range leaflet (still live), 2026-09 Marine & Leisure brochure, Exide Nordic datasheet (akkupoint.ch), NCC October 2023 Class A and March 2024 lists; NCC register dashboard (Class A) added as a source. Capacity, Wh, charge voltage, dimension and weight figures confirmed unchanged apart from the C-rate correction. | recheck | |
| 4 November 2026 | Fiat Ducato X290 (2014 on, including Series 8 and 9) (vehicles) | sources.checked | Re-read 4 November 2026: Fiat Ducato MY19 Owner Handbook, print no. 603.85.089 - 12/2019 - 1st Edition; "The replacement battery should be of the same type (L6 105Ah/850A)" unchanged; no alternator-control or leisure-battery wording; absences re-dated. | recheck | |
| 4 November 2026 | Fogstar Drift 12V 105Ah Lithium Leisure Battery (batteries) | capacity_ratings[0].end_voltage_v | was: 10 null: the sheet gives "Nominal Capacity 105Ah" with no rate or end voltage; "Discharge Cut Off Voltage 10V" stays in discharge.end_of_discharge_v | cdn.shopify.com | correction |
| 4 November 2026 | Fogstar Drift 12V 105Ah Lithium Leisure Battery (batteries) | sources.quote (marketed_as) | was: Nominal Capacity: 105Ah · Energy: 1280Wh · Nominal Voltage: 12V QUICK SPECS Energy 1280Wh · Nominal Capacity 105Ah · Nominal Voltage 12V (product page quick-spec list as worded on 2026-11-04; figures unchanged) | fogstar.co.uk | manufacturer_change |
| 4 November 2026 | Fogstar Drift 12V 105Ah Lithium Leisure Battery (batteries) | sources (charge) | was: absorption_v 14.4 cited only inside the sheet source note as "Recommended Charge Voltage: 14.4V" product-page charge source added with the current wording "Recommended Charge Voltage 14.4V"; value unchanged | fogstar.co.uk | recheck |
| 4 November 2026 | Fogstar Drift 12V 105Ah Lithium Leisure Battery (batteries) | sources.quote (bms) | was: Low Temperature Charging (UTC) Condition: Charging initiated at or near 0°C Action: Charging is temporarily paused. Incoming current is redirected to activate internal heating pads. Recovery: Charging resumes automatically once internal cell temperature reaches 5°C. quote corrected to the manual's wording "reaches ≥ 5°C"; manual "Low Temperature Cut-Off" at 0°C added to the note. low_temp_charge_cutoff_c 0 unchanged. | cdn.shopify.com | correction |
| 4 November 2026 | Fogstar Drift 12V 105Ah Lithium Leisure Battery (batteries) | retailers[0].price_gbp | was: 319.99 299.99 (Fogstar product page, 2026-11-04) | fogstar.co.uk | recheck |
| 4 November 2026 | Fogstar Drift 12V 105Ah Lithium Leisure Battery (batteries) | sources.checked | Re-read 4 November 2026: Fogstar Drift 105 Specification sheet (NEW_105Ah_Spec_Sept25, PDF created 2025-09-19, still the sheet linked from the product page; no newer datasheet PDF found), product page, Drift Range User Manual Version 1 (2026-06-30), Drift/Gen2/PRO warranty document (June 2026), NCC October 2023 and March 2024 lists. 105Ah, 1280Wh, 3500 @ 80% DOD, 14.2–14.4 V bulk, 13.5–13.8 V float, 100A charge and discharge, 10V cut-off, -10/-20 to 60 °C, 260 x 168 x 209 mm, 10 kg and the 10-year warranty confirmed unchanged. | cdn.shopify.com | recheck |
| 4 November 2026 | Ford Transit (2014 on) (vehicles) | sources.alternator_statement.quote | was: Fuse-table row: item number, fuse rating and component name (rating not repeated here) Smart regenerative charge inhibit relay. (component name only; fuse rating removed from the quote and from note) | fordservicecontent.com | correction |
| 4 November 2026 | Ford Transit (2014 on) (vehicles) | note | was: Could not be read (over 10 MB) on 2026-09-16: https://www.fordservicecontent.com/Ford_Content/Catalog/owner_information/CG3796en-202509-20250922095324.pdf (edition 202509); the 202110 edition was read instead. Answered: the 202509 edition (Vehicles Built From: 02-02-2026) was read on 2026-11-04 (HTTP 200); no MHEV section and no Smart regenerative charge inhibit relay entry; regenerative-braking text concerns the battery electric vehicle only. Recorded in note; alternator_statement unchanged (202110 wording). | fordservicecontent.com | recheck |
| 4 November 2026 | Ford Transit (2014 on) (vehicles) | sources.checked | Re-read 4 November 2026: FORD TRANSIT Owner's Manual CG3796en, Edition date 202110, First-Printing (HTTP 200; 403 to curl earlier that day); MHEV wording and fuse-table relay name confirmed unchanged; no second or leisure battery statement. | recheck | |
| 4 November 2026 | Ford Transit Custom (2013-2023) (vehicles) | sources | Added CG3900en (Vehicles Built From: 19-04-2021), the manual linked from https://www.ford.co.uk/support/vehicle/transit-custom/2022/owner-manuals (read in the browser 2026-11-04): same 48 volt mild hybrid / regenerative charging statement, coasting 'at a speed less than the engine stop speed that you have set'. | fordservicecontent.com | recheck |
| 4 November 2026 | Ford Transit Custom (2013-2023) (vehicles) | alternator_statement.applies_to | was: HYBRID VEHICLE OPERATION - MILD HYBRID ELECTRIC VEHICLE (MHEV) section of the owner's manual for Transit Custom (TTF) Kocaeli, Vehicles Built From: 27-01-2020 HYBRID VEHICLE OPERATION - MILD HYBRID ELECTRIC VEHICLE (MHEV) section of the owner's manuals for Transit Custom (TTF) Kocaeli, Vehicles Built From: 27-01-2020 (CG3763en) and Tourneo Custom/Transit Custom (TTF) Kocaeli, Vehicles Built From: 19-04-2021 (CG3900en) | fordservicecontent.com | recheck |
| 4 November 2026 | Ford Transit Custom (2013-2023) (vehicles) | sources.checked | Re-read 4 November 2026: FORD TRANSIT CUSTOM Owner's Manual CG3763en, Edition date 201911 (HTTP 200); MHEV wording ("... coasting at a speed of 12 km/h (7 mph).") confirmed unchanged; no second or leisure battery statement. | recheck | |
| 4 November 2026 | Ford Transit Custom (2023 on) (vehicles) | open_questions | was: Later editions of the Transit Custom (TTU) manual, and the PHEV variant's manual, were not read on 2026-09-16. Answered: CG3964en editions 202307 and 202402 (linked from the ford.co.uk 2024 Transit Custom owner-manuals page, read in the browser) were read on 2026-11-04; added as absence entries. The PHEV wording sits in these same manuals and concerns the high voltage battery. | fordservicecontent.com | recheck |
| 4 November 2026 | Ford Transit Custom (2023 on) (vehicles) | sources.checked | Re-read 4 November 2026: CG3964en Edition date 202304 (HTTP 200); no alternator, regenerative or smart-charging wording; absences re-dated. | recheck | |
| 4 November 2026 | Halfords Smart Battery Charger 6A (chargers) | sources.checked | Re-read 4 November 2026: Halfords battery-charger buying guide on help.halfords.com; the 'Smart Battery Charger (6A)' sentence, 7-stage lithium / 9-stage lead acid/AGM wording and one-touch button text are unchanged. Product-page status updated in open_questions. | help.halfords.com | recheck |
| 4 November 2026 | Labcraft Megalux PD1 surface-mount LED interior light, 10-32 V (appliances) | sources.checked | Re-read 4 November 2026: Labcraft Megalux product page (the cited /product/megalux-pd1/ URL now redirects to /products/interior-lighting/general-interior-lighting/megalux.html, same specification table) and megalux_data_sheet.pdf (undated); PD1_4-1MV '5W 12V @ 0.48A | 24V @ 0.26A' confirmed unchanged. | recheck | |
| 4 November 2026 | Labcraft Orizon 500 mm LED strip light, 12 V (appliances) | sources.checked | Re-read 4 November 2026: Labcraft Orizon product page specification table; LEDCW500PV3 '6.4W 12V @ 0.48A' confirmed unchanged. | recheck | |
| 4 November 2026 | Lucas LX31MF Leisure Battery 105Ah (batteries) | sources.checked | Re-read 4 November 2026: Lucas Leisure & Marine Battery Data Sheet (undated, Tayna-hosted), NCC October 2023 Class B and March 2024 lists; NCC register dashboard (Class B) added as a source. Every quoted capacity, CCA, dimension and weight figure confirmed unchanged. | recheck | |
| 4 November 2026 | Mercedes-Benz Sprinter (W907/V907, 2018 on) (vehicles) | open_questions | was: Could not be read (timeout) on 2026-09-16: https://www.mercedes-benz.co.uk/vans/services/manuals.html/sprinter-commercial-van-2019-06-p907-mbux/eco-startstop-function/eco-startstop-function-operation and https://www.mercedes-benz.co.uk/passengercars/services/manuals.html/sprinter-commercial-van-2025-06-c907-mbux/eco-startstop-function/how-the-eco-startstop-function-operates. The operator's manual may contain 'recuperation' wording. Both operator's-manual URLs now load in a browser; the ECO start/stop and 12 V battery pages were read and carry no alternator, recuperation or variable-voltage wording (added as absence entries). | mercedes-benz.co.uk | recheck |
| 4 November 2026 | Mercedes-Benz Sprinter (W907/V907, 2018 on) (vehicles) | sources.checked | Re-read 4 November 2026: Sprinter model information & price list (August 2018 production); alternator rows 14 V / 180 A to 14 V / 280 A, E2I auxiliary battery wording, ED1 "AGM battery, 12 V 70 Ah" and ED4 "Heavy-duty battery (12v 92 aH)" confirmed unchanged. | recheck | |
| 4 November 2026 | Mercedes-Benz Vito (W447, 2014 on) (vehicles) | alternator_statement.status | was: could_not_be_read absent: Vito May 2026 C447 MBUX online manual pages (ECO start/stop, 48 V battery, power availability display) read in the browser; no alternator-control wording | mercedes-benz.co.uk | recheck |
| 4 November 2026 | Mercedes-Benz Vito (W447, 2014 on) (vehicles) | factory_leisure_charging_statement.status | was: could_not_be_read absent: 'Notes on the 12 V battery' names an auxiliary battery location but no charging statement | mercedes-benz.co.uk | recheck |
| 4 November 2026 | Mercedes-Benz Vito (W447, 2014 on) (vehicles) | official_url | was: https://www.mercedes-benz.co.uk/passengercars/services/manuals.html/vito-commercial-van-2024-06-c447-mbux https://www.mercedes-benz.co.uk/vans/services/manuals.html/vito-commercial-van-2026-05-c447-mbux (old URL 404) | mercedes-benz.co.uk | recheck |
| 4 November 2026 | Mercedes-Benz Vito (W447, 2014 on) (vehicles) | sources | was: placeholder 'record' entry (Could not be read on 2026-09-16) four absence entries from the online manual pages read on 2026-11-04 | mercedes-benz.co.uk | recheck |
| 4 November 2026 | Mercedes-Benz Vito (W447, 2014 on) (vehicles) | alternator_statement.status, factory_leisure_charging_statement.status, sources, gaps | was: absent (four absence entries from online manual pages) could_not_be_read: the absence rested on selected online manual pages only; the full Owner's Manual PDF and the brochure (403) were not read, so a checked absence would overstate what was read. The pages read and their content are kept in the note. | mercedes-benz.co.uk | correction |
| 4 November 2026 | Nissan NV200 (vehicles) | sources.checked | Re-read 4 November 2026: Nissan UK NV200 van brochure (undated); alternator and 12 V battery rows and the DPF "REGENERATION" passage unchanged; no alternator-control or second-battery wording; absences re-dated. | recheck | |
| 4 November 2026 | NOCO Genius10 UK (chargers) | price_band_gbp | was: 128.67 116.68 (Tayna, '£ 116.68 inc. VAT', in stock, seen 4 November 2026) | tayna.co.uk | recheck |
| 4 November 2026 | NOCO Genius10 UK (chargers) | sources.checked | Re-read 4 November 2026: NOCO GENIUS10 User Guide & Warranty (NA edition, GENIUS10.04092024A) and no.co/genius10 product page; 12V 14.5V, 12V AGM 14.8V, 12V LITHIUM 14.6V (peak voltage measured at 25°C), 10A, up to 230AH, IP65 and the BMS caution confirmed unchanged. | no.co | recheck |
| 4 November 2026 | NOCO Genius5 UK (chargers) | price_band_gbp | was: 72.22 69.22 (Tayna, '£ 69.22 inc. VAT', in stock, seen 4 November 2026) | tayna.co.uk | recheck |
| 4 November 2026 | NOCO Genius5 UK (chargers) | sources.checked | Re-read 4 November 2026: NOCO GENIUS5 User Guide & Warranty (NA edition, GENIUS5.04182024A) and no.co/genius5 product page; 12V 14.5V, 12V AGM 14.8V, 12V LITHIUM 14.6V (peak voltage measured at 25°C), 5A, up to 120Ah, IP65 and the BMS caution confirmed unchanged. | no.co | recheck |
| 4 November 2026 | Numax LV26MF Sealed Leisure Battery (batteries) | sources.checked | Re-read 4 November 2026: Numax catalogue (undated, Tayna-hosted), NCC October 2023 Class C and March 2024 lists; NCC register dashboard (Class C) added as a source. Every quoted capacity, bench-charge, dimension and weight figure confirmed unchanged. | recheck | |
| 4 November 2026 | Numax XV31MF Sealed Leisure Battery (batteries) | sources.checked | Re-read 4 November 2026: Numax catalogue (undated, Tayna-hosted), NCC October 2023 Class A/B/C and March 2024 lists, NCC register dashboard (absence entry added); every quoted capacity, bench-charge, dimension and weight figure confirmed unchanged; still not NCC listed. | recheck | |
| 4 November 2026 | OptiMate 6 Ampmatic (chargers) | ip_rating | was: null (absence entry: no IP code found in the instructions) IP54 — 'IP rating IP54' in the PRODUCT INFORMATION table of the same instructions (TM18x-IN1-170208, PDF page 47) | tecmate.com | correction |
| 4 November 2026 | OptiMate 6 Ampmatic (chargers) | profiles[efb] | Added: published, voltages null — product page 'Automatically charge, test and maintain any size 12V AGM, GEL, EFB or STD starter or deep cycle battery'. | optimate1.com | recheck |
| 4 November 2026 | OptiMate 6 Ampmatic (chargers) | sources.checked | Re-read 4 November 2026: OptiMate 6 Ampmatic instructions (TM18x-IN1-170208, © 2017) and optimate1.com product page (MSRP GBP £114.99); DC 60W 12V 5A, 14.4V OPTIMIZE threshold, float 13.6V, 9 steps and 'Thermally adjusted' confirmed unchanged. Tayna still out of stock, no price shown. | tecmate.com | recheck |
| 4 November 2026 | OptiMate Lithium 4s 5A (chargers) | chemistry_mismatch_warning | was: AUTOMATIC CHARGER ONLY FOR 12.8V LIFEPO4 (LITHIUM IRON PHOSPHATE ) BATTERIES. A rechargeable LIFEPO4 battery should comply with IEC62133*. DO NOT USE FOR NiCd, NiMH, Lead-Acid or any other type of Li-Ion or AUTOMATIC CHARGER ONLY FOR 12.8V LIFEPO4 (LITHIUM IRON PHOSPHATE ) BATTERIES. A rechargeable LIFEPO4 battery should comply with IEC62133*. DO NOT USE FOR NiCd, NiMH, Lead-Acid or any other type of Li-Ion or NON-RECHARGEABLE BATTERIES. (completed from the same instructions, TM29x-IN1-170306) | optimate1.com | correction |
| 4 November 2026 | OptiMate Lithium 4s 5A (chargers) | sources[temperature_compensation].quote | was: The safeT program limits charge current if the temperature measured at the OptiMate Lithium is below 0°C / 32°F or above 45°C / 113°F. Made verbatim (safeTº, ºC/ºF as printed) and noted that safeTº limits charge current; no voltage coefficient is stated. | optimate1.com | correction |
| 4 November 2026 | OptiMate Lithium 4s 5A (chargers) | sources.checked | Re-read 4 November 2026: OptiMate Lithium 4s 5A instructions (TM29x-IN1-170306, © 2017), TM290 leaflet (TM290-5A-PL-150513_ALL, © 2013) and optimate1.com product page (MSRP GBP £119.99); 5A, 10 steps, 14.4V / 13.6V chart, leaflet 14.0–14.3V absorption pulses and 13.6V float, IP54 confirmed unchanged. | optimate1.com | recheck |
| 4 November 2026 | Peugeot Boxer (vehicles) | alternator_statement.status | was: could_not_be_read absent: peugeot.co.uk Boxer diesel page (browser) and the Boxer owner's manual PBOXRCO2512en-2 read; no diesel alternator-control wording | public.servicebox.peugeot.com | recheck |
| 4 November 2026 | Peugeot Boxer (vehicles) | factory_leisure_charging_statement.status | was: could_not_be_read absent: no second or leisure battery statement in PBOXRCO2512en-2 | public.servicebox.peugeot.com | recheck |
| 4 November 2026 | Peugeot Boxer (vehicles) | open_questions | was: Could not be read (403) on 2026-09-16: https://www.peugeot.co.uk/models/new-peugeot-boxer/diesel.html | Could not be read (HTML error page, not a PDF) on 2026-09-16: https://public.servicebox.peugeot.com/APddb/modeles/boxer/boxer_boxer/ed01-14/en_gb/boxer_boxer_boxer_ed01-14_en_gb.pdf (URL guessed from the Romanian edition path). Navigate the portal at https://public.servicebox.peugeot.com/APddb/ interactively to find the en-GB Boxer handbook. Answered: the model page loads in a browser and the en_us Boxer handbook ed12-25 PDF was found on Service Box and read. | public.servicebox.peugeot.com | recheck |
| 4 November 2026 | Peugeot Boxer (vehicles) | sources | was: placeholder 'record' entry (Could not be read on 2026-09-16) three absence entries from the two documents read on 2026-11-04 | public.servicebox.peugeot.com | recheck |
| 4 November 2026 | Platinum LB6110L Leisure Battery 12V 100Ah (batteries) | ncc | was: listed: true, class C, NCC/VB/C/020, 100 Ah, 70 cycles at 50% DoD, list 2023-10 (https://www.thencc.org.uk/media/xtbduhos/class-c-batteries.pdf) listed: false; class, reference, capacity, cycles, list date and list URL set to null. Not on the NCC register dashboard (Class A 106 rows, Class B 58 rows, Class C 94 rows) read 2026-11-04; the NCC page says the dashboard holds "verified batteries currently on our register". The October 2023 and March 2024 list entries stay as dated source entries. | lookerstudio.google.com | recheck |
| 4 November 2026 | Platinum LB6110L Leisure Battery 12V 100Ah (batteries) | summary | was: Sealed flooded leisure battery from Platinum International. The Platinum Leisure Product Guide gives 100 Ah (C20), 70 life cycles at 50% DOD, 351 x 174 x 188 mm and NCC Class C; no weight, charging voltage or DoD guidance is published. NCC Class C (Oct 2023: 100 Ah, 70 cycles at 50% DoD). Sealed flooded leisure battery from Platinum International. Its Leisure Product Guide gives 100 Ah (C20), 70 life cycles at 50% DOD, 351 x 174 x 188 mm and NCC Class C; no weight, charging voltage or DoD guidance. NCC Class C in the Oct 2023 list (100 Ah, 70 cycles); not on the NCC register read 2026-11-04. | lookerstudio.google.com | recheck |
| 4 November 2026 | Platinum LB6110L Leisure Battery 12V 100Ah (batteries) | sources.checked | Re-read 4 November 2026: Platinum Leisure Product Guide (undated, Tayna-hosted), Alliance Automotive Platinum page, NCC October 2023 Class C and March 2024 lists, NCC register dashboard; every quoted capacity, cycle and dimension figure confirmed unchanged. | recheck | |
| 4 November 2026 | REDARC BCDC1225D dual input 25A in-vehicle DC-DC battery charger (dcdc) | manufacturer_cable_fuse_table.wording | was: Pointer to Table 2.4.1 plus the vehicle input fuse rating and recommended fuse kit (values not repeated here) Refer to "Table 2.4.1: Cable Sizing" ... requirements. Fuse ratings removed from manufacturer_cable_fuse_table.wording and from the source note. Link unchanged: still REDARC's own manual, linked from the REDARC EU product page. | cdn.intelligencebank.com | correction |
| 4 November 2026 | REDARC BCDC1225D dual input 25A in-vehicle DC-DC battery charger (dcdc) | sources.checked | Re-read 4 November 2026: BCDC Dual Input instruction manual (REDARC CDN, no edition printed) and the REDARC EU product page; 25 A, 9 to 32 V, Li maximum 14.5 V, float 13.6 V for LiFePO4, trigger thresholds 12.9/12.7 V (standard) and 12.0/11.9 V (low voltage), tested every 100 seconds, every quoted figure confirmed unchanged. | recheck | |
| 4 November 2026 | Renault Trafic III (X82) (vehicles) | sources.checked | Re-read 4 November 2026: user-manual.renault.com Trafic pages "Stop and Start function" and "Battery"; quoted wording unchanged; no alternator, recuperation or second-battery wording; absences re-dated. | recheck | |
| 4 November 2026 | Renogy Core Mini 12.8V 100Ah Lithium Iron Phosphate Battery (batteries) | charge.absorption_v | was: null (UK page gives no charge voltage; manual link unresolved on 2026-09-16) 14.4: Core Mini user manual A0 (2024-08-07) "Bulk/Absorption Voltage 14.4V", "set the charge voltage, boost voltage, or bulk voltage at 14.4V (±0.2V)" | uk.renogy.com | recheck |
| 4 November 2026 | Renogy Core Mini 12.8V 100Ah Lithium Iron Phosphate Battery (batteries) | charge.profile | was: null cc_cv: manual Charging Logic "charging at a constant current of 50A until the battery voltage reaches 14.4V, followed by charging at a constant voltage of 14.4V" | uk.renogy.com | recheck |
| 4 November 2026 | Renogy Core Mini 12.8V 100Ah Lithium Iron Phosphate Battery (batteries) | discharge.end_of_discharge_v | was: null 10: manual "discharged at a constant current of 50A until the voltage drops to 10V"; "Undervoltage Shutdown 10.0V". Not applied to the capacity rating, whose end voltage is not stated. | uk.renogy.com | recheck |
| 4 November 2026 | Renogy Core Mini 12.8V 100Ah Lithium Iron Phosphate Battery (batteries) | bms.low_temp_charge_cutoff_c | was: null (not stated numerically) 0: manual "Charge Low Temperature Protection Trigger Battery Temperature ≤ 32°F (0°C) Recover ... ≥ 37.4°F (3°C)"; product page FAQ "prevent the battery from charging below 32°F / 0°C" | uk.renogy.com | recheck |
| 4 November 2026 | Renogy Core Mini 12.8V 100Ah Lithium Iron Phosphate Battery (batteries) | dod_guidance | was: published: false (product page states none) published: true, 100%, wording from the Core Mini user manual A0 introduction: "the battery can be safely discharged to 100% Depth of Discharge (DOD)" | uk.renogy.com | recheck |
| 4 November 2026 | Renogy Core Mini 12.8V 100Ah Lithium Iron Phosphate Battery (batteries) | summary | was: Compact LiFePO4 battery (Group 22NF) with built-in BMS. Renogy UK publishes 100 Ah rated at 0.5C/25 °C, 5000 cycles at 80% DOD to 80% EOL, 100 A max charge and discharge, charge 0–50 °C, discharge −20 to 60 °C, 229 x 138 x 213 mm, 9.9 kg. The charge voltage is not on the UK spec table. Compact LiFePO4 battery (Group 22NF) with built-in BMS. Renogy UK publishes 100 Ah rated at 0.5C/25 °C, 5000 cycles at 80% DOD to 80% EOL, 100 A max charge and discharge, charge 0–50 °C, discharge −20 to 60 °C, 229 x 138 x 213 mm, 9.9 kg. Its user manual gives a 14.4 V charge voltage. | uk.renogy.com | recheck |
| 4 November 2026 | Renogy Core Mini 12.8V 100Ah Lithium Iron Phosphate Battery (batteries) | retailers[0].price_gbp | was: 189.99 179.99 (Renogy UK product page, 2026-11-04) | uk.renogy.com | recheck |
| 4 November 2026 | Renogy Core Mini 12.8V 100Ah Lithium Iron Phosphate Battery (batteries) | sources.checked | Re-read 4 November 2026: uk.renogy.com Core Mini product page (Specs, comparison table, FAQ; read with curl, spec table present in the served HTML), Core Mini user manual VERSION A0 (2024-08-07, added), NCC October 2023 and March 2024 lists. 100Ah (0.5C, 25℃), 10–14.8 V, 100 A charge/discharge, 300A@5s, 0–50 °C charge, -20–60 °C discharge (page), 5000 cycles (80% DOD, 80% EOL), 229 x 138 x 213 mm, 9.9 kg confirmed unchanged. | uk.renogy.com | recheck |
| 4 November 2026 | Ring Automotive RSCDC30 DC-DC Smart Battery Charger 30A (dcdc) | sources.checked | Re-read 4 November 2026: Ring Vehicle Conversion Catalogue cat739 (no edition printed), DC-DC Smart Battery Charger page; Max output current 30A, input PV 10-50V / DC 12.6-50V, MPPT and the smart-alternator sentence confirmed unchanged; lithium and cable/fuse still absent from that page. Instruction PDF still image-only; product page still 404. | recheck | |
| 4 November 2026 | Ring SmartChargePro 25 (RSCPR25) (chargers) | sources.checked | Re-read 4 November 2026: Ring SmartChargePro instructions (RSCPR7/10/15/25/35/50/824, no edition printed) and Ring shop smart-chargers page; RSCPR25 2/6/12/25A, Gel 14.1v, AGM 14.4v, Lead Acid (Wet) and Calcium 14.7v, recondition/equalisation up to 16v, power supply 13.8v, eight listed stages and the external temperature sensor confirmed unchanged. | ringautomotive.com | recheck |
| 4 November 2026 | Roamer 105SMART5 MAX 12.8V 105Ah LiFePO4 (batteries) | sources.quote (cycle_life) | was: Cycle Life at 80% DoD CC Typical 8000 Cycle Life at 80% DoD Typical 8000 ("CC" belongs to the Cell Capacity row; 8000 cycles at 80% DoD unchanged) | roamer.com | correction |
| 4 November 2026 | Roamer 105SMART5 MAX 12.8V 105Ah LiFePO4 (batteries) | standards_claimed | was: gap (datasheet lists none; product page list noted but not quoted) IEC62619, UL9540A, UL1973 (cells) and CE, UKCA, RED, RoHS, ECE-R10, quoted verbatim from the product page | roamer.com | recheck |
| 4 November 2026 | Roamer 105SMART5 MAX 12.8V 105Ah LiFePO4 (batteries) | retailers[0].price_gbp | was: 389 419 (Roamer product page, 2026-11-04) | roamer.com | recheck |
| 4 November 2026 | Roamer 105SMART5 MAX 12.8V 105Ah LiFePO4 (batteries) | sources.checked | Re-read 4 November 2026: Roamer 105SMART5 MAX datasheet (Document Version 5.0, Release Date 13/02/2026, still the file linked from the product page), product page, NCC October 2023 and March 2024 lists. 105 (typical) / 116 (max) Ah, 1344 W(h), 8000 cycles at 80% DoD (typical), 13.8/14.2/14.6 V absorption, 13.5 V float, 13.25 V, 105 A BMS charge limit, 300 A / 350 A (30 s) discharge, 0–60 °C charge with 5 °C release, -20–60 °C discharge, parallel 16, 260 x 173 x 229 mm, 11 kg confirmed unchanged. | roamer.com | recheck |
| 4 November 2026 | Sargent EC155 on-board charger / power supply (chargers) | profile_evidence_notes.flooded_lead_acid | was: Issue 2 names standard lead-acid batteries; CAT017 names Flooded/AGM. Both state fixed 13.8 V output. Document applicability remains unresolved. Issue 2 names standard lead-acid batteries and a fixed-voltage 13.8 V supply; CAT017 names Flooded/AGM and lists the mains charger as '200W @14.5A/13.8V (max)'. Document applicability remains unresolved. CAT017 prints 13.8V inside '200W @14.5A/13.8V (max)' and does not call the output fixed; only Issue 2 says 'fixed voltage'. | sargentltd.co.uk | correction |
| 4 November 2026 | Sargent EC155 on-board charger / power supply (chargers) | sources.checked | Re-read 4 November 2026: EC155 User Instructions Issue 2 (June 2013; 13.8V DC up to a maximum of 12 Amps (155 Watts) shared with the leisure load, p1 '150W (~12A)', 75 to 120 Ah, lead acid / conditional Gel) and the EC155 product page ('£331.25 each inc. VAT'); CAT017 re-read for the profile notes. Every quoted figure confirmed unchanged. | sargentltd.co.uk | recheck |
| 4 November 2026 | Sargent EC155PSU (chargerEvidence) | claims[fixed-voltage].text | was: Both documents state a fixed 13.8 V output. Issue 2 states a fixed-voltage charger supplying 13.8 V DC; CAT017 lists the mains charger as '200W @14.5A/13.8V (max)'. CAT017 does not call the output fixed; the 13.8 V figure itself is unchanged. | sargentltd.co.uk | correction |
| 4 November 2026 | Sargent EC155PSU (chargerEvidence) | sources.checked | Re-read 4 November 2026: EC155 User Instructions Issue 2 (June 2013; p1 '150W (~12A)', §3.1 '13.8V DC ... up to a maximum of 12 Amps (155 Watts)' with the leisure load taking priority, §3.4 75 to 120 Ah) and CAT017 ('200W @14.5A/13.8V (max)', Flooded, AGM *, 60 - 155Ah). Other claim figures confirmed unchanged; no lithium statement in either. | sargentltd.co.uk | recheck |
| 4 November 2026 | Sargent PX300 (chargerEvidence) | claims[swift-current].text | was: The 2025 Swift Monza handbook states maximum 25 A / 300 W shared supply output, with leisure loads taking priority over battery charging. The 2025 Swift Monza handbook states the module supplies DC to the leisure equipment up to a maximum of 25 A (300 W), with the available power distributed between the leisure load and the battery. The handbook (p75) does not say that leisure loads take priority; that wording belongs to the EC155 Issue 2 instructions. The 25 A / 300 W shared-supply figures are unchanged. | swiftgroup.co.uk | correction |
| 4 November 2026 | Sargent PX300 (chargerEvidence) | sources.checked | Re-read 4 November 2026: Sargent PX300 support article (browser; 'Charging Current (max) 20A @ 14.5V', boost 14.4V, float 13.6V, 3-stage, 'up to 200Ah' and '85 - 220Ah'), Sargent lithium article (browser), Fogstar Knowledge Hub (Drift + PX300 statement; 13.5V - 13.8V float, 14.2v - 14.4V bulk) and Swift Monza handbook (Issued 2025, Part No. 1453854; PX300 at p63 and p75). Other figures confirmed unchanged. | sargent.zohodesk.eu | recheck |
| 4 November 2026 | Schaudt EBL119 / with OVP (chargerEvidence) | claims[battery-scope] | was: The manual names six-cell gel/AGM batteries from 80 Ah. (value 80 Ah) The manual names six-cell lead-gel or AGM batteries '80 Ah and above' in §5.2 (p9) but '55 Ah and above' in §4.1 (p8). No single minimum capacity is selected here. (value null, units Ah). Both statements are in the same 15.09.2015 edition, 811.0421 BA/EN; §4.1 was read visually. | res.cloudinary.com | correction |
| 4 November 2026 | Schaudt EBL119 / with OVP (chargerEvidence) | sources.checked | Re-read 4 November 2026: Schaudt EBL119 / with OVP manual (15.09.2015, 811.0421 BA/EN; 18 A, starter max. 2 A, lead-gel IUoU 14,4 V / 16 h, AGM 14,7 V / 4 h, float 13,7 V, restart below 13,7 V with ca. 5 sec. delay, Fig 3 EBL 30 caption) and the Dethleffs 2022 handbook (§9.8, pp165–167). Other figures confirmed unchanged; no lithium statement. | res.cloudinary.com | recheck |
| 4 November 2026 | Shurflo Trail King 7 caravan water pump, 7 l/min 20 psi, 12 V (appliances) | sources.checked | Re-read 4 November 2026: SHURflo Trail King 7 product sheet PDS-2095-204-112 (August 2001) on shurflo.eu; typical performance @ 12 VDC (1.5 / 2.5 / 3.3 A at 0 / 10 / 20 PSI) and Fuse 10 Amp Time Delay Recommended confirmed unchanged; open question re-dated. | recheck | |
| 4 November 2026 | Shurflo Trail King II RV/caravan fresh water pump, 12 V (appliances) | sources.checked | Re-read 4 November 2026: Pentair SHURflo Trail King II data sheet 4029-181-A43 [B43] Rev. 05/14; typical performance table at 12V (1.1 A open flow to 3.0 A at 30 PSI), Fuse 5 Amp Recommended, shut-off 25 PSI confirmed unchanged; no average current. | recheck | |
| 4 November 2026 | Sterling Power Pro Batt Ultra BB1230 12V-12V 30A battery to battery charger (dcdc) | manufacturer_cable_fuse_table.wording | was: Cable sizes by distance and the nominal fuse size, transcribed from the maker's table (values not repeated here) Recommended cable size for current required (table heading only). Cable and fuse values removed from manufacturer_cable_fuse_table.wording and from the source quote. Link unchanged: still Sterling's own V71 manual. | cdn.shopify.com | correction |
| 4 November 2026 | Sterling Power Pro Batt Ultra BB1230 12V-12V 30A battery to battery charger (dcdc) | sources.ignition_trigger.quote | was: 3 activation modes: 1) Automatic - Default, operates on input voltage (13.3V / 26.6V on) and complements regenerative braking with low voltage timer. No ignition feed required. 2) Ignition feed with timer. As above, however, requires a live ignition feed to operate. 3) Ignition feed without timer. Same text with '...' marking the omitted sentence 'Input voltage figures and timings, as above.' (quote made verbatim; field unchanged) | cdn.shopify.com | correction |
| 4 November 2026 | Sterling Power Pro Batt Ultra BB1230 12V-12V 30A battery to battery charger (dcdc) | open_questions | was: V71 manual 13.2V/13.0V vs catalogue page 20 13.6V/13.3V Added the Blue Stripe manual (March 2021 V4, 13.5V on / 13.3V off) and the product page (13.3V on / 13.0V off); both read 2026-11-04. engine_detection_thresholds left on the V71 wording, which the product page still labels 'Very Latest'. | cdn.shopify.com | recheck |
| 4 November 2026 | Sterling Power Pro Batt Ultra BB1230 12V-12V 30A battery to battery charger (dcdc) | summary | was: The manual's switch-on/off voltages differ from the catalogue page. its documents give different switch-on/off voltages (four Sterling documents read 2026-11-04 disagree; see open_questions) | cdn.shopify.com | recheck |
| 4 November 2026 | Sterling Power Pro Batt Ultra BB1230 12V-12V 30A battery to battery charger (dcdc) | sources.checked | Re-read 4 November 2026: Pro Batt Ultra English Manual V71+ (Feb 2020), catalogue page 20, Sterling product page (£118.80 seen), 12 Volt Planet product page and listing (£110.28 seen); also read the Blue Stripe manual (March 2021 V4). Input 11 - 20 V DC, input current 30 A, 13.2V/13.0V/240 s (V71) confirmed unchanged. | recheck | |
| 4 November 2026 | Sterling Power Pro Charge Ultra PCU1220 (12V 20A) (chargers) | profiles[*].wording | was: Preset-1 values only; second column unlabelled (open question) Preset-2 values added by row from the same instructions, read visually (p.07 and p.10): Open | Sealed lead 14.4/13.6, AGM 14.6/13.6, GEL 14.4/13.8, Lithium 0 deg C ** 14.6/14.0 VDC, second Lithium row CUSTOM - Li, Calcium / Custom CUSTOM - Pb, Desulphation 15.5/15.5. absorption_v/float_v keep the Preset-1 values. | cdn.shopify.com | recheck |
| 4 November 2026 | Sterling Power Pro Charge Ultra PCU1220 (12V 20A) (chargers) | open_questions | was: The battery-type table has a second column of profiles (14.4/13.6, 14.6/13.6, 14.4/13.8, 14.6/14.0 VDC) whose row labels did not survive text extraction; read the PDF visually and record which chemistries those belong to. Answered from the same instructions (see profiles wording); question removed. | cdn.shopify.com | recheck |
| 4 November 2026 | Sterling Power Pro Charge Ultra PCU1220 (12V 20A) (chargers) | sources.checked | Re-read 4 November 2026: Pro Charge Ultra Instructions (2022+ model, © 2021, New PCU Body Instructions) and the PCU1220 product page ('£348.38 GBP', IP22); 12V 20A approx 350W, Preset-1 voltages, -18mV per DegC from 20DegC, 0DegC lithium cutoff and the optional-fit sensor confirmed unchanged. | cdn.shopify.com | recheck |
| 4 November 2026 | Thetford T1090-E 12V compressor refrigerator (appliances) | figures.ah_per_24h | was: 25.6 (2026-range sheet 072025) 26.6 from 'Average Ampere Usage (Ah/24h)** 26.6 Ah/24h', 2027-range overview 072026, page 2, T1090-E column | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T1090-E 12V compressor refrigerator (appliances) | figures.test_standard | was: IEC62552-2020 part 3 IEC62552-2020 (2027 overview footnote '** According IEC62552-2020'; 'part 3' is no longer printed) | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T1090-E 12V compressor refrigerator (appliances) | sources | was: 2026-range sheet https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf (072025) 2027-range overview https://www.thetford.com/app/uploads/2026/08/Thetford_Overview_12V-Refrigerators_2027_EN.pdf (072026), linked from thetford.com/en/compressor-refrigerators/. kWh/24h 0.32 -> 0.34 kW/24h; climate class day/night SN - T (10 °C - 43°C) / SN (10 °C - 32 °C) -> ST (16 °C - 38°C) / N (16 °C - 32°C); part number 693483SP -> 693483SP. | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2095-E 12V compressor refrigerator (appliances) | figures.ah_per_24h | was: 30.0 (2026-range sheet 072025) 26.6 from 'Average Ampere Usage (Ah/24h)** 26.6 Ah/24h', 2027-range overview 072026, page 2, T2095-E column | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2095-E 12V compressor refrigerator (appliances) | figures.test_standard | was: IEC62552-2020 part 3 IEC62552-2020 (2027 overview footnote '** According IEC62552-2020'; 'part 3' is no longer printed) | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2095-E 12V compressor refrigerator (appliances) | sources | was: 2026-range sheet https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf (072025) 2027-range overview https://www.thetford.com/app/uploads/2026/08/Thetford_Overview_12V-Refrigerators_2027_EN.pdf (072026), linked from thetford.com/en/compressor-refrigerators/. kWh/24h 0.36 -> 0.36 kW/24h; part number 693461SP -> 692961SP. The 2026 sheet stays as a second ah_per_24h source because of the 26.6 question. | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2120-C 12V compressor refrigerator (appliances) | figures.ah_per_24h | was: 37.0 (2026-range sheet 072025) 37.1 from 'Average Ampere Usage (Ah/24h)** 37.1 Ah/24h', 2027-range overview 072026, page 2, T2120-C column | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2120-C 12V compressor refrigerator (appliances) | figures.test_standard | was: IEC62552-2020 part 3 IEC62552-2020 (2027 overview footnote '** According IEC62552-2020'; 'part 3' is no longer printed) | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2120-C 12V compressor refrigerator (appliances) | sources | was: 2026-range sheet https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf (072025) 2027-range overview https://www.thetford.com/app/uploads/2026/08/Thetford_Overview_12V-Refrigerators_2027_EN.pdf (072026), linked from thetford.com/en/compressor-refrigerators/. kWh/24h 0.45 -> 0.45 kW/24h; part number 693466SP -> 693092SP. | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2138-C 12V compressor refrigerator (appliances) | figures.ah_per_24h | was: 40.0 (2026-range sheet 072025) 42 from 'Average Ampere Usage ** 42.0 Ah/24h', 2027-range overview 072026, page 3, T2138-C column | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2138-C 12V compressor refrigerator (appliances) | figures.test_standard | was: IEC62552-2020 part 3 IEC62552-2020 (2027 overview footnote '** According IEC62552-2020'; 'part 3' is no longer printed) | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2138-C 12V compressor refrigerator (appliances) | sources | was: 2026-range sheet https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf (072025) 2027-range overview https://www.thetford.com/app/uploads/2026/08/Thetford_Overview_12V-Refrigerators_2027_EN.pdf (072026), linked from thetford.com/en/compressor-refrigerators/. kWh/24h 0.50 -> 0.50 kWh/24h; part number 693468SP -> 692935SP. | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2152-C 12V compressor refrigerator (appliances) | figures.ah_per_24h | was: 37.6 (2026-range sheet 072025) 39.1 from 'Average Ampere Usage ** 39.1 Ah/24h', 2027-range overview 072026, page 3, T2152-C column | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2152-C 12V compressor refrigerator (appliances) | figures.test_standard | was: IEC62552-2020 part 3 IEC62552-2020 (2027 overview footnote '** According IEC62552-2020'; 'part 3' is no longer printed) | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2152-C 12V compressor refrigerator (appliances) | sources | was: 2026-range sheet https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf (072025) 2027-range overview https://www.thetford.com/app/uploads/2026/08/Thetford_Overview_12V-Refrigerators_2027_EN.pdf (072026), linked from thetford.com/en/compressor-refrigerators/. kWh/24h 0.47 -> 0.46 kWh/24h; part number 693471SP -> 692937SP. | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2160-C 12V compressor refrigerator (appliances) | figures.ah_per_24h | was: 44.0 (2026-range sheet 072025) 45.8 from 'Average Ampere Usage ** 45.8 Ah/24h', 2027-range overview 072026, page 3, T2160-C column | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2160-C 12V compressor refrigerator (appliances) | figures.test_standard | was: IEC62552-2020 part 3 IEC62552-2020 (2027 overview footnote '** According IEC62552-2020'; 'part 3' is no longer printed) | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2160-C 12V compressor refrigerator (appliances) | sources | was: 2026-range sheet https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf (072025) 2027-range overview https://www.thetford.com/app/uploads/2026/08/Thetford_Overview_12V-Refrigerators_2027_EN.pdf (072026), linked from thetford.com/en/compressor-refrigerators/. kWh/24h 0.55 -> 0.56 kWh/24h; part number 693476SP -> 692943SP. | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2175-C 12V compressor refrigerator (appliances) | figures.ah_per_24h | was: 44.8 (2026-range sheet 072025) 46.5 from 'Average Ampere Usage ** 46.5 Ah/24h', 2027-range overview 072026, page 3, T2175-C column | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2175-C 12V compressor refrigerator (appliances) | figures.test_standard | was: IEC62552-2020 part 3 IEC62552-2020 (2027 overview footnote '** According IEC62552-2020'; 'part 3' is no longer printed) | thetford.com | manufacturer_change |
| 4 November 2026 | Thetford T2175-C 12V compressor refrigerator (appliances) | sources | was: 2026-range sheet https://www.thetford.com/app/uploads/2025/10/7.1_Thetford_12V-Refrigerators_2026_EN_LR.pdf (072025) 2027-range overview https://www.thetford.com/app/uploads/2026/08/Thetford_Overview_12V-Refrigerators_2027_EN.pdf (072026), linked from thetford.com/en/compressor-refrigerators/. kWh/24h 0.56 -> 0.56 kWh/24h; part number 693479SP -> 692946SP. | thetford.com | manufacturer_change |
| 4 November 2026 | Toyota Proace (vehicles) | sources.checked | Re-read 4 November 2026: Toyota UK Proace model page and the 2023 Proace price/specification sheet (221101); no diesel alternator or second-battery wording (the sheet says "All engines with the exception of 1.6 D (95 DIN hp) have stop/start."); absences re-dated. | recheck | |
| 4 November 2026 | Trojan 27TMX 12V Deep-Cycle Flooded Battery (batteries) | summary | was: Cycle life is published only as a graph. The data sheet gives no cycle-life figure. (Its only performance graph is discharge current against time; no cycles-vs-DoD graph or table is on the sheet.) | assets.ctfassets.net | correction |
| 4 November 2026 | Trojan 27TMX 12V Deep-Cycle Flooded Battery (batteries) | sources.note (physical) | was: Footnote F paraphrased as height to the terminal top Footnote F quoted in full: "Height taken from bottom of the battery to the highest point on the battery. Heights may vary depending on type of terminal." 247 mm unchanged. | assets.ctfassets.net | correction |
| 4 November 2026 | Trojan 27TMX 12V Deep-Cycle Flooded Battery (batteries) | marketed_as.note | was: Trojan lists all four rates side by side; the 20-Hr figure is 105 Ah. Tayna markets it by the 5-hour figure ("85Ah (C5)"). Trojan lists all four rates side by side; the 20-Hr figure is 105 Ah. Tayna's product page (read 2026-11-04) lists "Capacity (C5) 85 Ah" first, then C10, C20 and C100. | tayna.co.uk | recheck |
| 4 November 2026 | Trojan 27TMX 12V Deep-Cycle Flooded Battery (batteries) | retailers[0].price_gbp | was: 193.78 189.68 (Tayna product page, 2026-11-04) | tayna.co.uk | recheck |
| 4 November 2026 | Trojan 27TMX 12V Deep-Cycle Flooded Battery (batteries) | sources.checked | Re-read 4 November 2026: Trojan MOTIVE 27TMX data sheet (© 2019, code 27TMX.DS_020819, still the file linked from trojanbattery.com Signature Line datasheets), NCC October 2023 Class A/B/C and March 2024 lists. 85/97/105/117 Ah at 5/10/20/100-Hr to 1.75 V/cell at 27 °C, 14.82/13.50/16.20 V at 25 °C, 0.005 V/cell/°C, -20 to +45 °C, 326 x 168 x 247 mm and 25 kg confirmed unchanged. end_voltage_v 10.5 and -30 mV/°C remain 6-cell conversions of per-cell figures, as their notes say. | assets.ctfassets.net | recheck |
| 4 November 2026 | Truma Combi 4 gas combination heater (12 V control side) (appliances) | figures.quiescent_a | was: 0.001 (quote 'Quiescent current approx. 1 mA') removed; absence recorded: the page's 'Quiescent current' row is empty and 'approx. 1 mA' is printed against 'Water capacity' | truma.com | recheck |
| 4 November 2026 | Truma Combi 4 gas combination heater (12 V control side) (appliances) | sources.checked | Re-read 4 November 2026: Truma Combi 4 product page Technical Details; 'Power consumption (at 12 V): operation of heater and water container' => 'max. 6.5 A for short periods (average approx. 1.2 A)' confirmed unchanged (row pairing checked in the page's HTML). | recheck | |
| 4 November 2026 | Truma Combi 4 gas combination heater (12 V control side) (appliances) | sizing.note | was: The 6.5 A peak sizes the cable and fuse; The 6.5 A peak matters for the supply cable and fuse, which this site does not size; (no cable or fuse sizing in the site’s own voice, per the build’s safety constraints; Truma’s own wording, “max. 6.5 A for short periods”, is unchanged) | correction | |
| 4 November 2026 | Truma Combi D 6 E diesel combination heater (12 V control side) (appliances) | sources.checked | Re-read 4 November 2026: Truma Combi D 6 E product page Technical Details; '1.8 – 4 A (in normal operation between "Off" and "lowest operating level" less than 1.8 A)' and 'Quiescent current' => 'approx. 1 mA' confirmed unchanged (row pairing checked in the page's HTML). | recheck | |
| 4 November 2026 | Vauxhall Vivaro (2019 on) (vehicles) | alternator_statement.status | was: could_not_be_read absent: Vivaro owner's manuals February 2023 (ID-VVICORIE2302-en) and June 2020 (ID-VVICORIE2006-en) read (HTTP 200 on 2026-11-04; 403 on 2026-09-16); no alternator-control wording | vauxhall.co.uk | recheck |
| 4 November 2026 | Vauxhall Vivaro (2019 on) (vehicles) | factory_leisure_charging_statement.status | was: could_not_be_read absent: no second or leisure battery statement in the February 2023 manual | vauxhall.co.uk | recheck |
| 4 November 2026 | Vauxhall Vivaro (2019 on) (vehicles) | sources | was: placeholder 'record' entry (Could not be read on 2026-09-16) three absence entries from the two manuals read on 2026-11-04 | vauxhall.co.uk | recheck |
| 4 November 2026 | Victron AGM Deep Cycle Battery 12V 110Ah (batteries) | physical.terminal_type | was: copper (datasheet "Terminals: copper"; an M8-insert variant BAT412101085 is listed separately for the AGM) copper (datasheet "Terminals: copper"; product page: "M8 drilled, flat copper terminals"; an M8-insert version, BAT412101085 "12V/110Ah AGM Deep Cycle Batt. (M8)", is listed separately on the product page) (the M8-insert article is listed on the product page, not on the datasheet) | victronenergy.com | correction |
| 4 November 2026 | Victron AGM Deep Cycle Battery 12V 110Ah (batteries) | warranty | was: gap (datasheet carries no warranty term) 24 months: product page "come with Victron's 2 year world-wide warranty" | victronenergy.com | recheck |
| 4 November 2026 | Victron AGM Deep Cycle Battery 12V 110Ah (batteries) | standards_claimed | was: gap (datasheet cites no standards) CE and UL specifications, from the product page sentence "The batteries are compliant with both CE and UL specifications" | victronenergy.com | recheck |
| 4 November 2026 | Victron AGM Deep Cycle Battery 12V 110Ah (batteries) | sources.note (Table 1, discharge) | was: Table 1 transcribed as 3 hours 9,6 V and 5 min. with no end voltage; "9,6 V for 3-hour and shorter discharges" Table 1 reads 3 hours 10,8 V and 5 min. 9,6 V (9,6 V applies from the 1-hour row); the 5-second row has no end voltage. Recorded capacity (C20, 10,8 V) unchanged. | victronenergy.com | correction |
| 4 November 2026 | Victron AGM Deep Cycle Battery 12V 110Ah (batteries) | sources.quote (Table 3) | was: Victron AGM 'Deep Cycle' Victron AGM ‘Deep Cycle’ (verbatim punctuation); voltages unchanged | victronenergy.com | correction |
| 4 November 2026 | Victron AGM Deep Cycle Battery 12V 110Ah (batteries) | sources.checked | Re-read 4 November 2026: Victron Gel and AGM Batteries datasheet (PDF created 2025-12-09, no revision code printed), Gel and AGM Batteries product page, NCC October 2023 Class A/B/C and March 2024 lists. Ah, end voltages, cycle design life, Table 3 voltages, -24 mV/°C, 0,2 C, dimensions and weight confirmed unchanged; corrections listed in this date's other rows. | victronenergy.com | recheck |
| 4 November 2026 | Victron Blue Smart IP22 Charger 12/20 (1) (chargers) | sources.checked | Re-read 4 November 2026: Blue Smart IP22 230 VAC datasheet (still linked from the product page; no date printed), HTML manual Technical specifications and Setup pages, Simply Split Charge listing (£156.00 GBP, in stock). 12 V absorption 14,4/14,7/14,2 V, float 13,8/13,8/13,5 V, storage 13,2/13,2/13,5 V, 15/20/30 A, 6-stage adaptive (3 stage for Li-ion), -16mV/°C and IP22 confirmed unchanged. | victronenergy.com | recheck |
| 4 November 2026 | Victron Blue Smart IP65 Charger 12/15 (chargers) | sources.checked | Re-read 4 November 2026: IP65_A4_2022 datasheet (PDF 2022; table read visually), HTML manual Technical specifications, Safety, Operation and Setup pages, 12 Volt Planet listing (£102.82, awaiting new stock). 12 V absorption 14,4/14,7/14,2 V, float 13,8/13,8/13,5 V, storage 13,2/13,2/13,5 V, 4, 5, 7, 10, 15 and 25 A, 7-stage adaptive (4 stage for Li-ion), 16 mV/°C lead-acid only and IP65 confirmed unchanged. | victronenergy.com | recheck |
| 4 November 2026 | Victron Blue Smart IP67 Charger 12/25 (1) (chargers) | stages | was: 5 (stages_wording '5-stage adaptive') 6 (stages_wording '6-stage adaptive (3 stage for Li-ion)'): the re-issued datasheet's feature text now reads 'Adaptive 6-stage charge algorithm: bulk – absorption – recondition – float – storage – repeated absorption', matching the HTML manual; its specification row still reads '5-stage adaptive' (kept in the source note and open question). | victronenergy.com | manufacturer_change |
| 4 November 2026 | Victron Blue Smart IP67 Charger 12/25 (1) (chargers) | sources.checked | Re-read 4 November 2026: Blue Smart IP67 230 VAC datasheet (re-issued, rendered and read visually), HTML manual Technical specifications and Setup pages, 12 Volt Planet listing (£148.80). 12/25 25 A, absorption 14,4/14,7/14,2 V, float 13,8/13,8/13,5 V, storage 13,2/13,2/13,5 V, -16mV/°C and IP67 confirmed unchanged. | victronenergy.com | recheck |
| 4 November 2026 | Victron Energy Cyrix-ct 12/24V 120A intelligent battery combiner (relays) | sources.checked | Re-read 4 November 2026: Cyrix-ct 12/24 V 120 A and 230 A datasheet (undated), Cyrix-ct 120 manual Rev 05 (08-06-2022), Victron Cyrix family page, 12 Volt Planet (£42.30 seen); 120 A continuous / 180 A cranking, connection threshold 13 V to 13,8 V, disconnection threshold 11 V to 12,8 V and both delay tables confirmed unchanged. | recheck | |
| 4 November 2026 | Victron Energy Cyrix-Li-ct 12/24V 120A lithium battery combiner (relays) | sources.checked | Re-read 4 November 2026: Cyrix Li-ion 120 A series datasheet (undated) and the Victron Cyrix family page; 120 A, connection at 13,4V or more (120 s / 30 s / 4 s bands), disengage below 13,2V immediately, confirmed unchanged. | recheck | |
| 4 November 2026 | Victron Energy Orion XS 12/12-50A DC-DC battery charger (dcdc) | sources.document_edition | was: Rev 11 - 06/2026 Rev 12 - 09/2026 (same URL; sections renumbered, engine shutdown detection settings now 4.4.6, Euro 6 setup 4.1.2) | victronenergy.com | manufacturer_change |
| 4 November 2026 | Victron Energy Orion XS 12/12-50A DC-DC battery charger (dcdc) | engine_detection_thresholds | was: Delayed start voltage (Vstart(delay)) ... Default: 13.3V/26.6V (smart alternator) and 13.8/27.4V (regular alternator). Shutdown voltage (Vshutdown) ... Default: 13.1V/26.2V (smart alternator) and 13.5V/27V (regular alternator). Start voltage (Vstart): At this level, charging starts immediately. Default: 14V/28V. Delayed start voltage delay (tstart delay) ... Default: 120 seconds. Rev 12 default-values table (4.4.6), 12V system only: Vstart 14 V; Vstart(delay) 13.3 V smart / 13.8 V regular; tstart delay 120 s; Vshutdown 13.1 V smart / 13.5 V regular; input lock-out 12.5 V, restart 12.8 V (charger mode). 12 V figures unchanged. The old field's 24 V regular-alternator delayed-start figure '27.4V' is not in Rev 12, which gives 27,6 V; 24 V figures are no longer carried in this 12/12 record. | victronenergy.com | manufacturer_change |
| 4 November 2026 | Victron Energy Orion XS 12/12-50A DC-DC battery charger (dcdc) | sources.engine_detection_thresholds.clause | was: 4.5.6. Engine shutdown detection & input voltage lock-out 4.4.6. Engine shutdown detection & input voltage lock-out (Rev 12 numbering) | victronenergy.com | manufacturer_change |
| 4 November 2026 | Victron Energy Orion XS 12/12-50A DC-DC battery charger (dcdc) | sources.ignition_trigger.quote | was: The Orion XS can be set only to supply power when the engine is running. This is possible thanks to the integrated engine shutdown detection. This eliminates the need to adjust in-vehicle wiring or add an engine detection sensor to determine if charging can start. It also prevents the voltage on board the vehicle from getting too low. In addition to this detection, the Orion XS can also be forced on via the remote on/off port. Rev 12 wording ends 'In addition to this detection, an external engine running signal from the vehicle can be used to force charging on instead.' (was '... can also be forced on via the remote on/off port.'); ignition_trigger stays 'either' | victronenergy.com | manufacturer_change |
| 4 November 2026 | Victron Energy Orion XS 12/12-50A DC-DC battery charger (dcdc) | manufacturer_cable_fuse_table.wording | was: Fuse range and minimum cable gauges by length, transcribed from section 3.3 (values not repeated here) 3.3. Cable and fuse recommendations (section heading only). Cable and fuse values removed from manufacturer_cable_fuse_table.wording and from the source quote. Link unchanged: still Victron's own manual. | victronenergy.com | correction |
| 4 November 2026 | Victron Energy Orion XS 12/12-50A DC-DC battery charger (dcdc) | sources.checked | Re-read 4 November 2026: Manual - Orion XS 12/12-50A Rev 12 - 09/2026, Orion XS family product page, 12 Volt Planet (£231.43 seen); also the Orion XS datasheet. 1 - 50 A, 9-17 V, smart-alternator, lithium and preset wording confirmed unchanged. | recheck | |
| 4 November 2026 | Victron Energy Orion-Tr Smart 12/12-30A Isolated DC-DC charger (dcdc) | engine_detection_thresholds | was: Delayed start voltage (Vstart(delay)) ... Default: 13.3V (Smart Alternator) and 13.8 (Regular Alternator). Shutdown voltage (Vshutdown) ... Default: 13.1V (Smart Alternator) and 13.5V (Regular Alternator). Start voltage (Vstart): At this level, charging starts immediately. Default: 14V. Delayed start voltage delay (tstart delay) ... Default: 2 minutes. Rewritten from the Rev 14 manual's default-values table (5.2), 12V input model: Vstart 14V; Vstart(delay) 13.3V smart / 13.8V regular; tstart delay 120s; Vshutdown 13.1V smart / 13.5V regular. Figures unchanged; the old 'Default: ...' sentences and 'Default: 2 minutes' are not in the document. | victronenergy.com | correction |
| 4 November 2026 | Victron Energy Orion-Tr Smart 12/12-30A Isolated DC-DC charger (dcdc) | sources.engine_detection_thresholds.quote | was: Default: 13.3V (Smart Alternator) and 13.8 (Regular Alternator). Verbatim rows of the default-values table (see quote). | victronenergy.com | correction |
| 4 November 2026 | Victron Energy Orion-Tr Smart 12/12-30A Isolated DC-DC charger (dcdc) | profiles.user_defined.wording | was: The fixed or adaptive mode can be chosen in the battery settings Programmable charge algorithm and eight preprogrammed battery settings. (3. Features, 'Flexible charge algorithm'; the old wording described the absorption-time mode, not a user-defined profile) | victronenergy.com | correction |
| 4 November 2026 | Victron Energy Orion-Tr Smart 12/12-30A Isolated DC-DC charger (dcdc) | manufacturer_cable_fuse_table.wording | was: Fuse rating and minimum cable gauges by length for 12V, transcribed from Figure 6 (values not repeated here) Figure 6: Cable and fuse recommendations (figure title only). Cable and fuse values removed from manufacturer_cable_fuse_table.wording and from the source quote. Link unchanged: still Victron's own manual. | victronenergy.com | correction |
| 4 November 2026 | Victron Energy Orion-Tr Smart 12/12-30A Isolated DC-DC charger (dcdc) | sources.checked | Re-read 4 November 2026: Orion-Tr Smart DC-DC Charger Isolated manual Rev 14 - 02/2026 (same edition), product page, 12 Volt Planet (£211.46 seen). 30 A at nominal output voltage and 40°C, 8-17 V input, 200 V dc galvanic isolation confirmed unchanged. | recheck | |
| 4 November 2026 | Victron Gel Deep Cycle Battery 12V 110Ah (batteries) | physical.terminal_type | was: copper (datasheet "Terminals: copper"; an M8-insert variant BAT412101085 is listed separately for the AGM) copper (datasheet "Terminals: copper"; product page: "M8 drilled, flat copper terminals") (the M8-insert article is listed on the product page, not on the datasheet) | victronenergy.com | correction |
| 4 November 2026 | Victron Gel Deep Cycle Battery 12V 110Ah (batteries) | warranty | was: gap (datasheet carries no warranty term) 24 months: product page "come with Victron's 2 year world-wide warranty" | victronenergy.com | recheck |
| 4 November 2026 | Victron Gel Deep Cycle Battery 12V 110Ah (batteries) | standards_claimed | was: gap (datasheet cites no standards) CE and UL specifications, from the product page sentence "The batteries are compliant with both CE and UL specifications" | victronenergy.com | recheck |
| 4 November 2026 | Victron Gel Deep Cycle Battery 12V 110Ah (batteries) | sources.note (Table 1, discharge) | was: Table 1 transcribed as 3 hours 9,6 V and 5 min. with no end voltage; "9,6 V for 3-hour and shorter discharges" Table 1 reads 3 hours 10,8 V and 5 min. 9,6 V (9,6 V applies from the 1-hour row); the 5-second row has no end voltage. Recorded capacity (C20, 10,8 V) unchanged. | victronenergy.com | correction |
| 4 November 2026 | Victron Gel Deep Cycle Battery 12V 110Ah (batteries) | sources.quote (Table 3) | was: Victron Gel 'Deep Cycle' Victron Gel ‘Deep Cycle’ (verbatim punctuation); voltages unchanged | victronenergy.com | correction |
| 4 November 2026 | Victron Gel Deep Cycle Battery 12V 110Ah (batteries) | sources.checked | Re-read 4 November 2026: Victron Gel and AGM Batteries datasheet (PDF created 2025-12-09, no revision code printed), Gel and AGM Batteries product page, NCC October 2023 Class A/B/C and March 2024 lists. Ah, end voltages, cycle design life, Table 3 voltages, -24 mV/°C, 0,2 C, dimensions and weight confirmed unchanged; corrections listed in this date's other rows. | victronenergy.com | recheck |
| 4 November 2026 | Victron Lithium Battery Smart 12,8V/100Ah (batteries) | capacity_ratings[0].end_voltage_v | was: 11.2 null: the datasheet states the nominal capacity "@ 25 °C" with "Discharge current ≤1C" and no end voltage; 11.2 V stays in discharge.end_of_discharge_v, where the datasheet prints it | victronenergy.com | correction |
| 4 November 2026 | Victron Lithium Battery Smart 12,8V/100Ah (batteries) | dod_guidance | was: {"published":true,"recommended_max_dod_pct":80,"wording":"For Lithium-iron-phosphate (LiFePO4 or LFP) which is the safest of the mainstream Li-ion battery types, 80% DOD is used."} (wording from a 2015 Victron blog post comparing lithium and AGM in general) published: false; gap recorded against the datasheet and the Lithium Smart Battery Manual rev 21 (01/2026), neither of which states a recommended maximum DoD. The datasheet gives cycle life at 80 / 70 / 50 % DoD (2500 / 3000 / 5000 cycles, capacity ≥ 80 % of nominal). The blog post is general commentary, not this battery's guidance. | victronenergy.com | correction |
| 4 November 2026 | Victron Lithium Battery Smart 12,8V/100Ah (batteries) | bms.low_temp_charge_cutoff_c | was: null (not on the datasheet) 5: Lithium Smart Battery Manual rev 21, 4.7.3 "The default value is 5°C and the range is -20°C to +20°C" | victronenergy.com | recheck |
| 4 November 2026 | Victron Lithium Battery Smart 12,8V/100Ah (batteries) | bms.max_in_parallel | was: null 20: Lithium Smart Battery Manual rev 21, 4.5.4 "A total of 20 batteries can be connected in parallel." | victronenergy.com | recheck |
| 4 November 2026 | Victron Lithium Battery Smart 12,8V/100Ah (batteries) | aliases | was: BAT512110610 taken from a product listing BAT512110610 confirmed on Victron's product page version list ("LiFePO4 Battery 12,8V/100Ah Smart", "Article code BAT512110610"); alias unchanged | victronenergy.com | recheck |
| 4 November 2026 | Victron Lithium Battery Smart 12,8V/100Ah (batteries) | sources.checked | Re-read 4 November 2026: 12,8 & 25,6 Volt LFP Smart datasheet (PDF created 2024-08-26, no revision code printed), Lithium Smart Battery Manual rev 21 (01/2026, added), product page, NCC October 2023 and March 2024 lists. 100/80/50 Ah, 1280 Wh, cycle life, 14–14,4 V (14,2 V recommended), 13,5 V float, 200 A / ≤50 A charge, 200 A / ≤100 A discharge, 11.2 V, 5–50 °C charge, -20–50 °C discharge, dimensions and weight confirmed unchanged. | victronenergy.com | recheck |
| 4 November 2026 | Victron Phoenix Inverter 12/1200 VE.Direct (appliances) | official_url | was: https://www.victronenergy.com/inverters/phoenix-inverter-vedirect https://www.victronenergy.com/inverters/phoenix-inverter-vedirect-250va-800va (old product URL returns 404 on 2026-11-04; Victron's Inverters listing links this page, titled 'Inverter VE.Direct', which links the cited 250VA–1600VA datasheet) | victronenergy.com | manufacturer_change |
| 4 November 2026 | Victron Phoenix Inverter 12/1200 VE.Direct (appliances) | sources.checked | Re-read 4 November 2026: Victron 'Inverters VE.Direct 250VA – 1600VA' datasheet (no printed date); 12/1200 column figures confirmed unchanged by table-mode extraction. | recheck | |
| 4 November 2026 | Victron Phoenix Inverter 12/500 VE.Direct (appliances) | official_url | was: https://www.victronenergy.com/inverters/phoenix-inverter-vedirect https://www.victronenergy.com/inverters/phoenix-inverter-vedirect-250va-800va (old product URL returns 404 on 2026-11-04; Victron's Inverters listing links this page, titled 'Inverter VE.Direct', which links the cited 250VA–1600VA datasheet) | victronenergy.com | manufacturer_change |
| 4 November 2026 | Victron Phoenix Inverter 12/500 VE.Direct (appliances) | sources.checked | Re-read 4 November 2026: Victron 'Inverters VE.Direct 250VA – 1600VA' datasheet (no printed date); 12/500 column figures confirmed unchanged by table-mode extraction. | recheck | |
| 4 November 2026 | Victron Skylla-IP44 12/60 (1+1) (chargers) | open_questions | was: The 3.3 battery-selection table needs a visual read to confirm the 12 V / 24 V column alignment for types 4–8 (text extraction interleaved the rows). Answered: the 3.3 table was read visually from the same manual; the 12 V values used in profiles (14,1 / 14,4 / 14,7 / 14,2 V absorption, 13,8 V float, LiFePo4 float n.a., storage 13,50) are confirmed and types 4–9 are recorded in the source note. Question removed. | victronenergy.com | recheck |
| 4 November 2026 | Victron Skylla-IP44 12/60 (1+1) (chargers) | sources[output_a].note | Added the datasheet's footnote (2) condition for the 60 A rating: 'Up to 40°C (100°F) ambient. Output will reduce to 80% at 50°C, and to 60% at 60°C.' | victronenergy.com | recheck |
| 4 November 2026 | Victron Skylla-IP44 12/60 (1+1) (chargers) | sources.checked | Re-read 4 November 2026: Skylla-IP44 datasheet (PDF 2019) and six-language manual (PDF 2019); 60 A, 14,4/13,8/13,2 V default, 7 stage adaptive, Li-Ion 3 stage (datasheet) vs four-stage LiFePo4 curve (manual), 14,2 V LiFePo4 absorption, IP44 and the supplied temperature sensor confirmed unchanged. | victronenergy.com | recheck |
| 4 November 2026 | Vitrifrigo C51i CHR compressor fridge-freezer (daily figure in Wh only) (appliances) | sources[figures.ah_per_24h] | was: absent: product page technical data lists no power, current, Wh or Ah figure (checked 2026-09-16) product page now states 'Consumption (Wh/24h) 229'; absence entry and the figures.ah_per_24h gap removed; the quote is kept as a sizing.note source because a Wh figure cannot fill ah_per_24h without a voltage | vitrifrigo.com | manufacturer_change |
| 4 November 2026 | Vitrifrigo C51i CHR compressor fridge-freezer (daily figure in Wh only) (appliances) | name | was: Vitrifrigo C51i CHR compressor fridge-freezer (consumption not published) Vitrifrigo C51i CHR compressor fridge-freezer (daily figure in Wh only) | vitrifrigo.com | manufacturer_change |
| 4 November 2026 | Vitrifrigo C51i CHR compressor fridge-freezer (daily figure in Wh only) (appliances) | generic_label | was: 12V compressor fridge, 51 litre class (Vitrifrigo C51i; no maker consumption figure) 12V compressor fridge, 51 litre class (Vitrifrigo C51i; maker gives Wh/24h only, no 12 V current) | vitrifrigo.com | manufacturer_change |
| 4 November 2026 | Vitrifrigo C51i CHR compressor fridge-freezer (daily figure in Wh only) (appliances) | sizing.note | was: Vitrifrigo publishes no consumption figure for the C51i CHR: the datasheet's 'Absorption / Consumo' row is printed 'N.A.' and the product page's technical data lists only volume, dimensions, weight, thermostat, cooling unit and 'Supply 12/24 Vdc'. The reader must enter their own figure. A Vitrifrigo news article about the C51i HP variant reports a test result, not a specification; see open_questions. Vitrifrigo's product page now lists 'Consumption (Wh/24h) 229' (read 2026-11-04) with no test conditions and no supply voltage beyond 'Supply 12/24 Vdc'. Its datasheet still prints 'N.A.' in the 'Absorption / Consumo' row. No 12 V current and no Ah figure is published, and converting Wh to Ah would need a voltage the maker does not state, so the reader enters their own figure. A Vitrifrigo news article about the C51i HP variant reports a test result, not a specification; see open_questions. | vitrifrigo.com | manufacturer_change |
| 4 November 2026 | Vitrifrigo C51i CHR compressor fridge-freezer (daily figure in Wh only) (appliances) | sources.checked | Re-read 4 November 2026 in the browser: Vitrifrigo C51i CHR Grey product page and C51i_CHR datasheet (undated); the datasheet's 'Absorption / Consumo' row still prints 'N.A.'. | recheck | |
| 4 November 2026 | Volkswagen Crafter (2017 on) (vehicles) | sources.checked | Re-read 4 November 2026: Volkswagen Commercial Vehicles UK TDI technology page; the "All our Euro 6 TDI and BiTDI engines ... regenerative braking as standard" sentence confirmed unchanged; no second-battery statement. | recheck | |
| 4 November 2026 | Volkswagen Transporter T5 (vehicles) | sources.checked | Re-read 4 November 2026: Volkswagen Commercial Vehicles UK TDI technology page; its only charging statement still concerns "All our Euro 6 TDI and BiTDI engines" and names no model; absence re-dated. | recheck | |
| 4 November 2026 | Volkswagen Transporter T6 (vehicles) | sources.checked | Re-read 4 November 2026: Volkswagen Commercial Vehicles UK TDI technology page; the "All our Euro 6 TDI and BiTDI engines ... regenerative braking as standard" sentence confirmed unchanged; no second-battery statement. | recheck | |
| 4 November 2026 | Volkswagen Transporter T6.1 (vehicles) | sources.checked | Re-read 4 November 2026: Volkswagen Commercial Vehicles UK TDI technology page; the "All our Euro 6 TDI and BiTDI engines ... regenerative braking as standard" sentence confirmed unchanged; no second-battery statement. | recheck | |
| 4 November 2026 | Webasto Air Top 2000 STC diesel air heater (12 V) (appliances) | sizing.note | was: Webasto publishes running consumption as a control range, 'Rated power consumption, control range (W) 15 – 30' for the 12 V diesel heater, so the answer is a range, not a point. The start-up figure, 'The Air Top 2000 STC requires 75 watts at 12 or 24 volts during start-up', is EXCLUDED from the Ah total because Webasto publishes no start-up duration: a wattage with no time cannot become amp-hours. Webasto's own two 2024 datasheets disagree on the lower bound for 12 V diesel (15 W in the product datasheet, 13 W in the RV-market datasheet); the product datasheet figure is used. Added the US manual's 'Rated power consumption 14 - 29 W' to the recorded disagreement and the product page's production-stopped notice; figures unchanged (15 – 30 W, 75 W start-up excluded). | webasto.com | recheck |
| 4 November 2026 | Webasto Air Top 2000 STC diesel air heater (12 V) (appliances) | sources.checked | Re-read 4 November 2026: Webasto Air Top 2000 STC datasheet 07/24 ('Rated power consumption, control range (W) 15 – 30 13 – 28 15 – 30') and the Webasto US installation manual P/N 5012634C (75 W start-up, no duration) confirmed unchanged; the 08/24 RV-market datasheet returns 404 and keeps its 2026-09-16 date. | recheck | |
| 4 November 2026 | Whale Premium submersible pump GP1352, 12 V (appliances) | sources.checked | Re-read 4 November 2026: Whale RV Catalogue page 12 on docs.navico.com (linked from whale.navico.com); GP1352 3.6 / 3.3 / 2.9 A at 0 / 1 / 3 m confirmed unchanged (column order read from the page text layer: Standard GP1002, Premium GP1352/GP1354, High Flow GP1652). | recheck | |
| 4 November 2026 | Whale Watermaster exterior water pump EP1612, 12 V (appliances) | sources.checked | Re-read 4 November 2026: Whale RV Catalogue page 16 on docs.navico.com; EP1612/EP1622/EP1642 3.8 / 3.7 / 3.5 A at 0 / 1 / 3 m confirmed unchanged; EP1652 still not in the catalogue. | recheck | |
| 4 November 2026 | Yuasa L36-AGM YBX Active Leisure AGM 12V 95Ah (batteries) | sources.checked | Re-read 4 November 2026: NCC October 2023 Class A and March 2024 lists; NCC register dashboard (Class A) added as a source. The yuasa.com product page and data sheet could not be re-read (403 / bot challenge); their entries keep the 2026-09-16 date and quotes. | recheck | |
| 4 November 2026 | Yuasa L36-EFB YBX Active Leisure EFB 12V 100Ah (batteries) | sources[ncc October 2023 Class B].quote | was: Yuasa L36-EFB 56.75 353 175 190 100 223 NCC/VB/B/026 Yuasa L36-EFB 24 353 175 190 100 223 NCC/VB/B/026 (pdftotext -raw and -table agree; 56.75 is the Weight of the Bosch L5080 row above, misaligned by the -layout extraction used on 2026-09-16) | thencc.org.uk | correction |
| 4 November 2026 | Yuasa L36-EFB YBX Active Leisure EFB 12V 100Ah (batteries) | sources[ncc March 2024].quote | was: Yuasa L36-EFB 56.75 353 175 190 Yuasa L36-EFB 24 353 175 190 | thencc.org.uk | correction |
| 4 November 2026 | Yuasa L36-EFB YBX Active Leisure EFB 12V 100Ah (batteries) | open_questions | was: The NCC Oct 2023 Class B list shows a weight of 56.75 for L36-EFB (Yuasa data sheet: 24 kg); likely a list error, not transcribed. Removed: the October 2023 Class B list, the March 2024 list and the NCC register all give L36-EFB a weight of 24; the 56.75 was our misreading (it belongs to the Bosch L5080 row). | thencc.org.uk | correction |
| 4 November 2026 | Yuasa L36-EFB YBX Active Leisure EFB 12V 100Ah (batteries) | sources.checked | Re-read 4 November 2026: NCC October 2023 Class B and March 2024 lists; NCC register dashboard (Class B) added as a source. The yuasa.com product page and data sheet could not be re-read (403 / bot challenge); their entries keep the 2026-09-16 date and quotes. | recheck | |
| 21 September 2026 | CBE CB522-LT (chargerEvidence) | onboard_evidence | Added source-scoped onboard charger evidence; no automatic compatibility or current verdict. | seed | |
| 21 September 2026 | Sargent EC155 on-board charger / power supply (chargers) | output_a | was: 12 A without conflict qualification Unresolved between Issue 2 (12 A shared output) and CAT017 (14.5 A); numeric comparison withheld. | sargentltd.co.uk | recheck |
| 21 September 2026 | Sargent EC155PSU (chargerEvidence) | onboard_evidence | Added source-scoped onboard charger evidence; no automatic compatibility or current verdict. | seed | |
| 21 September 2026 | Sargent PX300 (chargerEvidence) | onboard_evidence | Added source-scoped onboard charger evidence; no automatic compatibility or current verdict. | seed | |
| 21 September 2026 | Schaudt EBL119 / with OVP (chargerEvidence) | onboard_evidence | Added source-scoped onboard charger evidence; no automatic compatibility or current verdict. | seed | |
| 20 September 2026 | Renogy Core Mini 12.8V 100Ah Lithium Iron Phosphate Battery (batteries) | capacity_ratings.rate | was: unstated because C2 was missing from the schema 100 Ah at C2 (published 0.5C), 25 °C; removed the erroneous rate absence. No C20 rating inferred. | uk.renogy.com | correction |
| 20 September 2026 | Victron AGM Deep Cycle Battery 12V 110Ah (batteries) | summary | was: 0.2C described as a charge-current ceiling 0.2C described as preferred charge-current guidance; source section 15 retains temperature-compensation qualification above this current | victronenergy.com | correction |
| 20 September 2026 | Victron Gel Deep Cycle Battery 12V 110Ah (batteries) | summary | was: 0.2C described as a charge-current ceiling 0.2C described as preferred charge-current guidance; source section 15 retains temperature-compensation qualification above this current | victronenergy.com | correction |
| 16 September 2026 | Banner Energy Bull 955 51 (batteries) | seed | record created from the Banner Energy Bull German brochure (download file=455) technical data table | bannerbatterien.com | seed |
| 16 September 2026 | Banner Energy Bull 957 51 (batteries) | seed | record created from the Banner Energy Bull brochure technical data table | akkumulatorhaz.hu | seed |
| 16 September 2026 | Banner Energy Bull 957 51 (batteries) | sources | was: Brochure read on a distributor server (akkumulatorhaz.hu) Re-sourced on bannerbatterien.com: Technical Data Sheet DBTBAT00339 (2020-09-30, file=4710), product page and German brochure (file=455); weight, charging voltage, DoD guidance, cycle figure, NCC listing and retailers added | bannerbatterien.com | recheck |
| 16 September 2026 | Banner Energy Bull 959 01 (batteries) | seed | record created from the Banner Energy Bull German brochure (download file=455) technical data table | bannerbatterien.com | seed |
| 16 September 2026 | Banner Energy Bull 968 01 (batteries) | seed | record created from the Banner Technical Data Sheet for Energy Bull 968 01 (Document DBTBAT00339, 2020-09-30) | bannerbatterien.com | seed |
| 16 September 2026 | CBE MP2USBC double USB charging socket (USB-A + USB-C), 12 V input (appliances) | seed | record created from the CBE MP2USBC product page | cbe.it | seed |
| 16 September 2026 | Citroen Relay (Jumper) (vehicles) | seed | record created; absence recorded against the Citroen Relay / Jumper handbook eGuide ed01-21 (en-GB) | service.citroen.com | seed |
| 16 September 2026 | CTEK CS ONE (Gen 2) (chargers) | seed | record created from the CTEK CS ONE (GEN 2) product sheet and user manual | ctek.com | seed |
| 16 September 2026 | CTEK D250SE dual input 20A DC-DC charger with MPPT (dcdc) | seed | record created from the CTEK D250SE product sheet (UK-EN) and the D250SE & SMARTPASS 120S user manual (UK-EN) | ctek.com | seed |
| 16 September 2026 | CTEK LITHIUM XS (chargers) | seed | record created from the CTEK LITHIUM XS Manual (UK-EN) | ctek.com | seed |
| 16 September 2026 | CTEK MXS 10 (chargers) | seed | record created from the CTEK MXS 10 UK product page and manual safety page | ctek.com | seed |
| 16 September 2026 | CTEK MXS 5.0 (chargers) | seed | record created from the CTEK MXS 5.0 Manual (UK-EN) | ctek.com | seed |
| 16 September 2026 | Dometic CoolMatic CRX 50 compressor fridge (appliances) | seed | record created from the Dometic catalogue CRX 50/65 page and the CRX 50 installation and operating manual | media.dometic.com | seed |
| 16 September 2026 | Dometic CoolMatic CRX 50 compressor fridge (appliances) | sources | was: rated_a sourced to dometic-coolmatic-crx-50-e_9600028416_75862.pdf; official_url set to a dometic.com product page rated_a re-read in the CRX50/CRX65 manual 4445102664 (08/2020) on media.dometic.com; official_url set to null because every dometic.com CRX 50 product URL returned 404 or a category redirect; 1.1 vs 1.4 Ah/h question resolved to 1.1 in the catalogue | media.dometic.com | recheck |
| 16 September 2026 | Dometic CoolMatic CRX 65 compressor fridge (appliances) | seed | record created from the Dometic catalogue CRX 50/65 page and the CRX50, CRX65 installation and operating manual 4445102664 | media.dometic.com | seed |
| 16 September 2026 | Dometic CoolMatic CRX 80 compressor fridge (appliances) | seed | record created from the Dometic catalogue CRX 80/110 page and the CRX series installation and operating manual 4445102565 | media.dometic.com | seed |
| 16 September 2026 | Dometic RM 5330 3-way absorption fridge on 12 V (appliances) | seed | record created from the Dometic RM5310/RM5330/RM5380 installation and operating manual 4445102234 | media.dometic.com | seed |
| 16 September 2026 | Dometic RUA 5208X 3-way absorption fridge on 12 V (appliances) | seed | record created from the Dometic RUA 5208X/6408X/8408X installation and operating manual 4445102445 | media.dometic.com | seed |
| 16 September 2026 | Dometic RUA 6408X 3-way absorption fridge on 12 V (appliances) | seed | record created from the Dometic RUA 5208X/6408X/8408X installation and operating manual 4445102445 | media.dometic.com | seed |
| 16 September 2026 | Dometic RUA 8408X 3-way absorption fridge on 12 V (appliances) | seed | record created from the Dometic RUA 5208X/6408X/8408X installation and operating manual 4445102445 | media.dometic.com | seed |
| 16 September 2026 | Durite 0-727-10 12V 100A extra heavy duty make/break relay (relays) | seed | record created from the Durite Technical Information Sheet Part No. 0-727-10 and the durite.co.uk product page | durite.co.uk | seed |
| 16 September 2026 | Durite 0-727-23 12V 70/20A double contact split charge relay (relays) | seed | record created from the Durite Technical Information Sheet Part No. 0-727-23 and the durite.co.uk product page | durite.co.uk | seed |
| 16 September 2026 | Durite 0-727-33 12V 140A voltage sensitive relay (relays) | seed | record created from the Durite Technical Information Sheet Part No. 0-727-33 and the durite.co.uk product page | durite.co.uk | seed |
| 16 September 2026 | Durite 0-727-43 12V 200A Smart Programmable Voltage Sensitive Relay (relays) | seed | record created from the Durite 0-727-43 leaflet and the durite.co.uk product page | durite.co.uk | seed |
| 16 September 2026 | Eberspächer Airtronic S2 D2L diesel air heater (12 V) (appliances) | seed | record created from the Eberspächer Airtronic S2 & M2 technical documentation 29.2100.20.1046 Issue C | eberspaecher-climate.com | seed |
| 16 September 2026 | Exide Equipment GEL ES1200 (batteries) | seed | record created from the Exide ES1200 product page, the Exide full range leaflet and the Exide Equipment GEL datasheet | exidegroup.com | seed |
| 16 September 2026 | Exide Equipment GEL ES1300 (batteries) | seed | record created from the Exide ES1300 product page, the Exide full range leaflet and the Exide Equipment GEL datasheet | exidegroup.com | seed |
| 16 September 2026 | Fiat Ducato X290 (2014 on, including Series 8 and 9) (vehicles) | seed | record created; absence recorded against the FIAT DUCATO OWNER HANDBOOK MY19 (603.85.089 EN) | aftersales.fiat.com | seed |
| 16 September 2026 | Fogstar Drift 12V 105Ah Lithium Leisure Battery (batteries) | seed | record created from the Fogstar Drift 105 Specification sheet (Sept25) and product page | cdn.shopify.com | seed |
| 16 September 2026 | Ford Transit (2014 on) (vehicles) | seed | record created from the FORD TRANSIT Owner's Manual CG3796en (edition 202110) | fordservicecontent.com | seed |
| 16 September 2026 | Ford Transit Custom (2013-2023) (vehicles) | seed | record created from the FORD TRANSIT CUSTOM Owner's Manual CG3763en (edition 201911) | fordservicecontent.com | seed |
| 16 September 2026 | Ford Transit Custom (2023 on) (vehicles) | seed | record created; absence recorded against the FORD TOURNEO CUSTOM / TRANSIT CUSTOM Owner's manual CG3964en | fordservicecontent.com | seed |
| 16 September 2026 | Halfords Smart Battery Charger 6A (chargers) | seed | record created from the Halfords battery charger buying guide on help.halfords.com | help.halfords.com | seed |
| 16 September 2026 | Labcraft Megalux PD1 surface-mount LED interior light, 10-32 V (appliances) | seed | record created from the Labcraft Megalux PD1 product page and Megalux datasheet | labcraft.co.uk | seed |
| 16 September 2026 | Labcraft Orizon 500 mm LED strip light, 12 V (appliances) | seed | record created from the Labcraft Orizon product page specification table | labcraft.co.uk | seed |
| 16 September 2026 | Lucas LX31MF Leisure Battery 105Ah (batteries) | seed | record created from the Lucas Leisure & Marine Battery Data Sheet (Tayna-hosted) | cdn.tayna.com | seed |
| 16 September 2026 | Mercedes-Benz Sprinter (W907/V907, 2018 on) (vehicles) | seed | record created from the Mercedes-Benz UK Sprinter model information & price list (August 2018 production) | tools.mercedes-benz.co.uk | seed |
| 16 September 2026 | Mercedes-Benz Vito (W447, 2014 on) (vehicles) | seed | placeholder record created; no Mercedes-Benz Vito document could be read | seed | |
| 16 September 2026 | Nissan NV200 (vehicles) | seed | record created; absence recorded against the Nissan UK NV200 van brochure | nissan-cdn.net | seed |
| 16 September 2026 | NOCO Genius10 UK (chargers) | seed | record created from the NOCO GENIUS10 User Guide & Warranty | no.co | seed |
| 16 September 2026 | NOCO Genius5 UK (chargers) | seed | record created from the NOCO GENIUS5 User Guide & Warranty | no.co | seed |
| 16 September 2026 | Numax LV26MF Sealed Leisure Battery (batteries) | seed | record created from the Numax battery catalogue (Tayna-hosted) | cdn.tayna.com | seed |
| 16 September 2026 | Numax XV31MF Sealed Leisure Battery (batteries) | seed | record created from the Numax battery catalogue (Tayna-hosted) | cdn.tayna.com | seed |
| 16 September 2026 | OptiMate 6 Ampmatic (chargers) | seed | record created from the OptiMate 6 Ampmatic instructions for use and product page | tecmate.com | seed |
| 16 September 2026 | OptiMate Lithium 4s 5A (chargers) | seed | record created from the OptiMate Lithium 4s 5A instructions for use and TM290 product leaflet | optimate1.com | seed |
| 16 September 2026 | Peugeot Boxer (vehicles) | seed | placeholder record created; no Peugeot Boxer document could be read | seed | |
| 16 September 2026 | Platinum LB6110L Leisure Battery 12V 100Ah (batteries) | seed | record created from the Platinum Leisure Product Guide (Tayna-hosted) | cdn.tayna.com | seed |
| 16 September 2026 | REDARC BCDC1225D dual input 25A in-vehicle DC-DC battery charger (dcdc) | seed | record created from the REDARC BCDC Dual Input Multi-Stage In-Vehicle Battery Charger instruction manual and the REDARC EU product page | cdn.intelligencebank.com | seed |
| 16 September 2026 | Renault Trafic III (X82) (vehicles) | seed | record created; absence recorded against the Renault Trafic online user manual (Stop and Start function; Battery) | user-manual.renault.com | seed |
| 16 September 2026 | Renogy Core Mini 12.8V 100Ah Lithium Iron Phosphate Battery (batteries) | seed | record created from the Renogy UK Core Mini 12.8V 100Ah product page (Specs tab) | uk.renogy.com | seed |
| 16 September 2026 | Ring Automotive RSCDC30 DC-DC Smart Battery Charger 30A (dcdc) | seed | record created from the Ring Automotive Vehicle Conversion Catalogue (cat739) DC-DC Smart Battery Charger page | ringautomotive.com | seed |
| 16 September 2026 | Ring SmartChargePro 25 (RSCPR25) (chargers) | seed | record created from the Ring SmartChargePro Instructions PDF | ringautomotive.com | seed |
| 16 September 2026 | Roamer 105SMART5 MAX 12.8V 105Ah LiFePO4 (batteries) | seed | record created from the Roamer 105SMART5 MAX datasheet (Document Version 5.0, 13/02/2026) | roamer.com | seed |
| 16 September 2026 | Sargent EC155 on-board charger / power supply (chargers) | seed | record created from the Sargent EC155 User Instructions Issue 2 | sargentltd.co.uk | seed |
| 16 September 2026 | Shurflo Trail King 7 caravan water pump, 7 l/min 20 psi, 12 V (appliances) | seed | record created from the SHURflo Trail King 7 product sheet PDS-2095-204-112 (August 2001) | shurflo.eu | seed |
| 16 September 2026 | Shurflo Trail King II RV/caravan fresh water pump, 12 V (appliances) | seed | record created from the Pentair SHURflo Trail King II product technical data sheet 4029-181-A43 Rev. 05/14 | pentair.com | seed |
| 16 September 2026 | Sterling Power Pro Batt Ultra BB1230 12V-12V 30A battery to battery charger (dcdc) | seed | record created from Sterling Power Pro Batt Ultra English Manual V71+ (Feb 2020) and the sterling-power.com product page | cdn.shopify.com | seed |
| 16 September 2026 | Sterling Power Pro Charge Ultra PCU1220 (12V 20A) (chargers) | seed | record created from the Sterling Power Pro Charge Ultra Instructions (2022+ model) | cdn.shopify.com | seed |
| 16 September 2026 | Thetford T1090-E 12V compressor refrigerator (appliances) | seed | record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025) | thetford.com | seed |
| 16 September 2026 | Thetford T2095-E 12V compressor refrigerator (appliances) | seed | record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025) | thetford.com | seed |
| 16 September 2026 | Thetford T2120-C 12V compressor refrigerator (appliances) | seed | record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025) | thetford.com | seed |
| 16 September 2026 | Thetford T2138-C 12V compressor refrigerator (appliances) | seed | record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025) | thetford.com | seed |
| 16 September 2026 | Thetford T2152-C 12V compressor refrigerator (appliances) | seed | record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025) | thetford.com | seed |
| 16 September 2026 | Thetford T2160-C 12V compressor refrigerator (appliances) | seed | record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025) | thetford.com | seed |
| 16 September 2026 | Thetford T2175-C 12V compressor refrigerator (appliances) | seed | record created from the Thetford '12V Compressor refrigerators' 2026 range sheet (072025) | thetford.com | seed |
| 16 September 2026 | Toyota Proace (vehicles) | seed | record created; absence recorded against the Toyota UK Proace page and 2023 price and specification sheet | toyota.co.uk | seed |
| 16 September 2026 | Trojan 27TMX 12V Deep-Cycle Flooded Battery (batteries) | seed | record created from the Trojan MOTIVE 27TMX data sheet | assets.ctfassets.net | seed |
| 16 September 2026 | Truma Combi 4 gas combination heater (12 V control side) (appliances) | seed | record created from the Truma Combi 4 product page (Technical Details) | truma.com | seed |
| 16 September 2026 | Truma Combi D 6 E diesel combination heater (12 V control side) (appliances) | seed | record created from the Truma Combi D 6 E product page (Technical Details) | truma.com | seed |
| 16 September 2026 | Vauxhall Vivaro (2019 on) (vehicles) | seed | placeholder record created; every Vauxhall page and PDF returned 403 | seed | |
| 16 September 2026 | Victron AGM Deep Cycle Battery 12V 110Ah (batteries) | seed | record created from the Victron Energy Gel and AGM Batteries datasheet | victronenergy.com | seed |
| 16 September 2026 | Victron Blue Smart IP22 Charger 12/20 (1) (chargers) | seed | record created from the Blue Smart IP22 Charger 230 VAC datasheet and HTML manual | victronenergy.com | seed |
| 16 September 2026 | Victron Blue Smart IP65 Charger 12/15 (chargers) | seed | record created from the Blue Smart IP65 Charger datasheet and HTML manual | victronenergy.com | seed |
| 16 September 2026 | Victron Blue Smart IP67 Charger 12/25 (1) (chargers) | seed | record created from the Blue Smart IP67 Charger 230 VAC datasheet and HTML manual | victronenergy.com | seed |
| 16 September 2026 | Victron Energy Cyrix-ct 12/24V 120A intelligent battery combiner (relays) | seed | record created from the Cyrix-ct 12/24 V 120 A and 230 A datasheet and the Cyrix-ct 120 manual Rev 05 | victronenergy.com | seed |
| 16 September 2026 | Victron Energy Cyrix-Li-ct 12/24V 120A lithium battery combiner (relays) | seed | record created from the Cyrix Li-ion 120 A series datasheet | victronenergy.com | seed |
| 16 September 2026 | Victron Energy Orion XS 12/12-50A DC-DC battery charger (dcdc) | seed | record created from Manual - Orion XS 12/12-50A DC-DC battery charger Rev 11 - 06/2026 | victronenergy.com | seed |
| 16 September 2026 | Victron Energy Orion-Tr Smart 12/12-30A Isolated DC-DC charger (dcdc) | seed | record created from Orion-Tr Smart DC-DC Charger Isolated manual Rev 14 - 02/2026 | victronenergy.com | seed |
| 16 September 2026 | Victron Gel Deep Cycle Battery 12V 110Ah (batteries) | seed | record created from the Victron Energy Gel and AGM Batteries datasheet | victronenergy.com | seed |
| 16 September 2026 | Victron Lithium Battery Smart 12,8V/100Ah (batteries) | seed | record created from the Victron Energy 12,8 & 25,6 Volt Lithium-Iron-Phosphate Batteries Smart datasheet | victronenergy.com | seed |
| 16 September 2026 | Victron Phoenix Inverter 12/1200 VE.Direct (appliances) | seed | record created from the Victron Inverters VE.Direct 250VA–1600VA datasheet | victronenergy.com | seed |
| 16 September 2026 | Victron Phoenix Inverter 12/500 VE.Direct (appliances) | seed | record created from the Victron Inverters VE.Direct 250VA–1600VA datasheet | victronenergy.com | seed |
| 16 September 2026 | Victron Skylla-IP44 12/60 (1+1) (chargers) | seed | record created from the Skylla-IP44 datasheet and manual | victronenergy.com | seed |
| 16 September 2026 | Vitrifrigo C51i CHR compressor fridge-freezer (daily figure in Wh only) (appliances) | seed | record created from the Vitrifrigo C51i CHR datasheet and product page (absence recorded) | vitrifrigo.com | seed |
| 16 September 2026 | Volkswagen Crafter (2017 on) (vehicles) | seed | record created from the Volkswagen Commercial Vehicles UK TDI technology page | volkswagen-vans.co.uk | seed |
| 16 September 2026 | Volkswagen Transporter T5 (vehicles) | seed | record created; absence recorded against the Volkswagen Commercial Vehicles UK TDI technology page | volkswagen-vans.co.uk | seed |
| 16 September 2026 | Volkswagen Transporter T6 (vehicles) | seed | record created from the Volkswagen Commercial Vehicles UK TDI technology page | volkswagen-vans.co.uk | seed |
| 16 September 2026 | Volkswagen Transporter T6.1 (vehicles) | seed | record created from the Volkswagen Commercial Vehicles UK TDI technology page | volkswagen-vans.co.uk | seed |
| 16 September 2026 | Webasto Air Top 2000 STC diesel air heater (12 V) (appliances) | seed | record created from the Webasto Air Top 2000 STC datasheet (07/24) and the Webasto US installation manual P/N 5012634C | webasto.com | seed |
| 16 September 2026 | Whale Premium submersible pump GP1352, 12 V (appliances) | seed | record created from the Whale RV Catalogue page 12 (Submersible Pump Range) | docs.navico.com | seed |
| 16 September 2026 | Whale Watermaster exterior water pump EP1612, 12 V (appliances) | seed | record created from the Whale RV Catalogue page 16 (Watermaster Exterior Water Pump Range) | docs.navico.com | seed |
| 16 September 2026 | Yuasa L36-AGM YBX Active Leisure AGM 12V 95Ah (batteries) | seed | record created from the GS Yuasa UK L36-AGM product page and Yuasa Technical Data Sheet | yuasa.com | seed |
| 16 September 2026 | Yuasa L36-EFB YBX Active Leisure EFB 12V 100Ah (batteries) | seed | record created from the GS Yuasa UK L36-EFB product page and Yuasa Technical Data Sheet | yuasa.com | seed |
Corrections
Corrections received through the corrections page appear above with the label “correction” once verified and applied, or are answered with the source relied on if no change is made. None received yet.